Design and performance of the prototype full field breast tomosynthesis system with selenium based flat panel detector

被引:66
作者
Ren, BR [1 ]
Ruth, C [1 ]
Stein, J [1 ]
Smith, A [1 ]
Shaw, I [1 ]
Jing, ZX [1 ]
机构
[1] Hol Inc, Bedford, MA 01730 USA
来源
Medical Imaging 2005: Physics of Medical Imaging, Pts 1 and 2 | 2005年 / 5745卷
关键词
breast tomosynthesis; full field digital mammography; flat panel detector; selenium direct conversion detector; MTF; depth of field; signal to noise ratio; spatial resolution; spectra optimization; DIGITAL MAMMOGRAPHY;
D O I
10.1117/12.595833
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We have developed a breast tomosynthesis system utilizing a selenium-based direct conversion flat panel detector. This prototype system is a modification of Selenia, Hologic's full field digital mammography system, using an add-on breast holding device to allow 3D tomosynthetic imaging. During a tomosynthesis scan, the breast is held stationary while the x-ray source and detector mounted on a c-arm rotate continuously around the breast over an angular range up to 30 degrees. The x-ray tube is pulsed to acquire 11 projections at desired c-arm angles. Images are reconstructed in planes parallel to the breastplate using a filtered backprojection algorithm. Processing time is typically 1 minute for a 50 mm thick breast at 0.1 mm in-plane pixel size, 1 mm slice-to-slice separation. Clinical studies are in progress. Performance evaluations were carried out at the system and the subsystem levels including spatial resolution, signal-to-noise ratio, spectra optimization, imaging technique, and phantom and patient studies. Experimental results show that we have successfully built a tomosynthesis system with images showing less structure noise and revealing 3D information compared with the conventional mammogram. We introduce, for the first time, the definition of "Depth of Field" for tomosynthesis based on a spatial resolution study. This parameter is used together with Modulation Transfer Function (MTF) to evaluate 3D resolution of a tomosynthesis system as a function of system design, imaging technique, and reconstruction algorithm. Findings from the on-going clinical studies will help the design of the next generation tomosynthesis system offering improved performance.
引用
收藏
页码:550 / 561
页数:12
相关论文
共 14 条
[1]  
BOCHUD FO, SPIE, V3036, P74
[2]   Glandular breast dose for monoenergetic and high-energy X-ray beams: Monte Carlo assessment [J].
Boone, JM .
RADIOLOGY, 1999, 213 (01) :23-37
[3]  
Chen B., MED PHYS, V29, P755
[4]   OPTIMIZATION OF SPECTRAL SHAPE IN DIGITAL MAMMOGRAPHY - DEPENDENCE ON ANODE MATERIAL, BREAST THICKNESS, AND LESION TYPE [J].
FAHRIG, R ;
YAFFE, MJ .
MEDICAL PHYSICS, 1994, 21 (09) :1473-1481
[5]  
FLYNN M, SPIE, V5030, P147
[6]  
KEELAN BW, SPIE, V5372, P230
[7]  
LEHTIMAKI M, P SPIE, V5029, P698
[8]   Digital Tomosynthesis in breast imaging [J].
Niklason, LT ;
Christian, BT ;
Niklason, LE ;
Kopans, DB ;
Castleberry, DE ;
OpsahlOng, BH ;
Landberg, CE ;
Slanetz, PJ ;
Giardino, AA ;
Moore, R ;
Albagli, D ;
DeJule, MC ;
Fitzgerald, PF ;
Fobare, DF ;
Giambattista, BW ;
Kwasnick, RF ;
Liu, JQ ;
Lubowski, SJ ;
Possin, GE ;
Richotte, JF ;
Wei, CY ;
Wirth, RF .
RADIOLOGY, 1997, 205 (02) :399-406
[9]  
RAFFERTY EA, 2002, RADIOLOGY S, V225, P683
[10]  
RAFFERTY EA, 2003, RADIOLOGY S, V229, P423