Testing for irritation with a multifactorial approach: comparison of eight non-invasive measuring techniques on five different irritation types

被引:58
作者
Fluhr, JW
Kuss, O
Diepgen, T
Lazzerini, S
Pelosi, A
Gloor, M
Berardesca, E
机构
[1] Univ Pavia, IRCCS Policlin San Mateo, Dept Dermatol, I-27100 Pavia, Italy
[2] Heidelberg Univ, Dept Clin Social Med, D-69115 Heidelberg, Germany
[3] Klinikum Karlsruhe, Dept Dermatol, D-76133 Karlsruhe, Germany
关键词
dithranol; multivariate analysis; sodium lauryl sulphate; tape stripping; tretinoin; ultraviolet irradiation;
D O I
10.1046/j.1365-2133.2001.04431.x
中图分类号
R75 [皮肤病学与性病学];
学科分类号
100206 ;
摘要
Background Non-invasive bioengineering methods are widely used in the assessment of irritant skin reactions. Objectives To assess the ability of eight non-invasive measurement techniques to distinguish changes in skin conditions over time, these changes being induced by five different irritants. Methods The following techniques were compared in a multivariate analysis: laser-Doppler perfusion imaging (LDI), laser-Doppler flowmetry (EDF), transepidermal water loss (TEWL), visual scoring (VS), colorimetric measurements (Chromameter CR 200 a* and L* scales), Mexameter Hb scale (Mexa Hb) and capacitance (Corneometer CM 820). Irritants tested were sodium lauryl sulphate 2% (SLS), tape stripping (TS), tretinoin 0.05% (TRET), ultraviolet (UV) exposure to 30 W m(-2) UVB/95 W m(-2) UVA, and dithranol 0.5% (DIT). Measurements were performed at baseline and after 24, 48 and 72 h. The study was conducted on the upper back of 11 healthy volunteers of both sexes aged 27-31 years. Results For DIT it was possible to discriminate over time with CR 200 a* and L*, VS, LDI, LDF and Mexa HE In SLS discrimination over time was seen with TEWL and LDF. Discrimination in TS was demonstrated for TEWL, VS, CR 200 a*, CM 820, LDF, LDI and Mexa Hb. In TRET discrimination ability was seen for LDI, LDF, Mexa Hb and VS. For UV it was possible to discriminate using VS, TEWL, LDF, LDI and Mexa Hb. Conclusions Different irritation patterns need different measurement modalities in order to give optimal discrimination over time.
引用
收藏
页码:696 / 703
页数:8
相关论文
共 33 条
[1]   SODIUM LAURYL SULFATE FOR IRRITANT PATCH TESTING - A DOSE-RESPONSE STUDY USING BIOENGINEERING METHODS FOR DETERMINATION OF SKIN IRRITATION [J].
AGNER, T ;
SERUP, J .
JOURNAL OF INVESTIGATIVE DERMATOLOGY, 1990, 95 (05) :543-547
[2]   DIFFERENT SKIN IRRITATION ABILITIES OF DIFFERENT QUALITIES OF SODIUM LAURYL SULFATE [J].
AGNER, T ;
SERUP, J ;
HANDLOS, V ;
BATSBERG, W .
CONTACT DERMATITIS, 1989, 21 (03) :184-188
[3]   SKIN REACTIONS TO IRRITANTS ASSESSED BY NON-INVASIVE BIOENGINEERING METHODS [J].
AGNER, T ;
SERUP, J .
CONTACT DERMATITIS, 1989, 20 (05) :352-359
[4]   BASAL TRANSEPIDERMAL WATER-LOSS, SKIN THICKNESS, SKIN BLOOD-FLOW AND SKIN COLOR IN RELATION TO SODIUM-LAURYL-SULFATE-INDUCED IRRITATION IN NORMAL SKIN [J].
AGNER, T .
CONTACT DERMATITIS, 1991, 25 (02) :108-114
[5]   SKIN IRRITATION IN MAN - A COMPARATIVE BIOENGINEERING STUDY USING IMPROVED REFLECTANCE SPECTROSCOPY [J].
ANDERSEN, PH ;
MAIBACH, HI .
CONTACT DERMATITIS, 1995, 33 (05) :315-322
[6]   THE MODULATION OF SKIN IRRITATION [J].
BERARDESCA, E ;
DISTANTE, F .
CONTACT DERMATITIS, 1994, 31 (05) :281-287
[7]  
Berardesca E, 1997, Skin Res Technol, V3, P126, DOI 10.1111/j.1600-0846.1997.tb00174.x
[8]   SODIUM LAURYL SULFATE INDUCED CUTANEOUS IRRITATION - COMPARISON OF WHITE AND HISPANIC SUBJECTS [J].
BERARDESCA, E ;
MAIBACH, HI .
CONTACT DERMATITIS, 1988, 19 (02) :136-140
[9]   GUIDELINES FOR MEASUREMENT OF CUTANEOUS BLOOD-FLOW BY LASER-DOPPLER FLOWMETRY - A REPORT FROM THE STANDARDIZATION GROUP OF THE EUROPEAN-SOCIETY-OF-CONTACT-DERMATITIS [J].
BIRCHER, A ;
DEBOER, EM ;
AGNER, T ;
WAHLBERG, JE ;
SERUP, J .
CONTACT DERMATITIS, 1994, 30 (02) :65-72
[10]  
Effendy I, 1995, ACTA DERM-VENEREOL, V75, P455