Microfabrication and characterization of an ion-selective microelectrode array platform

被引:18
作者
Guenat, OT
Dufour, JF
van der Wal, PD
Morf, WE
de Rooij, NF
Koudelka-Hep, M
机构
[1] Univ Neuchatel, Inst Microtechnol, Sensors Actuators & Microsyst Lab, CH-2007 Neuchatel, Switzerland
[2] Univ Bern, Dept Clin Pharmacol, Signal Transduct Grp, CH-3010 Bern, Switzerland
来源
SENSORS AND ACTUATORS B-CHEMICAL | 2005年 / 105卷 / 01期
关键词
ion-selective electrodes array; micropipettes; intracellular recording;
D O I
10.1016/j.snb.2004.02.037
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The design and the fabrication of an ion-selective electrode array platform aimed at in vitro intracellular recording are presented. The platform is composed of two parts: (i) a glass chip with microchannels whose bottom part is patterned with a platinum layer and (ii) a silicon chip in which an array of 50 mum long silicon nitride micropipettes with an inner diameter of 5 mum are structured. The 24 micropipettes are individually filled with a Ca2+ selective membrane, based on the neutral ionophore ETH 129. Preliminary tests in Ca2+ buffered solutions have shown a linear range from 10(-6) to 0.1 M Ca2+ with a sensitivity of 27 mV/decade. (C) 2004 Elsevier B.V. All lights reserved.
引用
收藏
页码:65 / 73
页数:9
相关论文
共 17 条
[1]   CONTROLLED SYNTHESIS OF HBSAG IN A DIFFERENTIATED HUMAN-LIVER CARCINOMA-DERIVED CELL-LINE [J].
ADEN, DP ;
FOGEL, A ;
PLOTKIN, S ;
DAMJANOV, I ;
KNOWLES, BB .
NATURE, 1979, 282 (5739) :615-616
[2]   INTRACELLULAR NEUTRAL CARRIER-BASED CA-2+ MICROELECTRODE WITH SUBNANOMOLAR DETECTION LIMIT [J].
AMMANN, D ;
BUHRER, T ;
SCHEFER, U ;
MULLER, M ;
SIMON, W .
PFLUGERS ARCHIV-EUROPEAN JOURNAL OF PHYSIOLOGY, 1987, 409 (03) :223-228
[3]  
AMMANN D, 1986, PRINCIPLES DESIGN AP
[4]  
BAUDET S, 1994, METHOD CELL BIOL, V40, P93
[5]  
Baudet S., 1994, METHOD CELL BIOL, V40
[6]   The versatility and universality of calcium signalling [J].
Berridge, MJ ;
Lipp, P ;
Bootman, MD .
NATURE REVIEWS MOLECULAR CELL BIOLOGY, 2000, 1 (01) :11-21
[7]   Fabrication of array of hollow microcapillaries used for injection of genetic materials into animal/plant cells [J].
Chun, K ;
Hashiguchi, G ;
Toshiyoshi, H ;
Fujita, H .
JAPANESE JOURNAL OF APPLIED PHYSICS PART 2-LETTERS, 1999, 38 (3A) :L279-L281
[8]   MICROFABRICATED SENSOR ARRAYS SENSITIVE TO PH AND K+ FOR IONIC DISTRIBUTION MEASUREMENTS IN THE BEATING HEART [J].
COSOFRET, VV ;
ERDOSY, M ;
JOHNSON, TA ;
BUCK, RP ;
ASH, RB ;
NEUMAN, MR .
ANALYTICAL CHEMISTRY, 1995, 67 (10) :1647-1653
[9]  
FERTIG N, 2001, PHYS REV E, V64
[10]  
HAUGLAND RP, 1999, FLUORESCENT LUMINESC, P40