High-performance liquid chromatography with ultraviolet detection for therapeutic drug monitoring of everolimus

被引:27
作者
Baldelli, S
Murgia, S
Merlini, S
Zenoni, S
Perico, N
Remuzzi, G
Cattaneo, D
机构
[1] Mario Negri Inst Pharmacol Res, Osped Riuniti Bergamo, Dept Med & Transplantat, I-24125 Bergamo, Italy
[2] Mario Negri Inst Pharmacol Res, Ctr Res Organ Transplantat Chiara Cucchi Alessand, I-24100 Bergamo, Italy
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2005年 / 816卷 / 1-2期
关键词
everolimus; validation; high-performance liquid chromatography;
D O I
10.1016/j.jchromb.2004.11.016
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We developed and validated a high-performance liquid chromatography-ultraviolet (HPLC-UV) method for determining everolimus concentrations in human whole blood. Sample preparation involved a solid-phase extraction after protein precipitation. The separation of everolimus from internal standard (IS) and endogenous components was achieved using an isocratic elution on an octyl column. The method showed a linear relationship between peak height ratios and blood concentrations in the range of 1-200 ng/mL (r(2) = 0.9997). The observed intra- and inter-day assay imprecision had a coefficient of variation (CV) = 12.8%, and inaccuracy was 11.4%. The method was found to be precise, accurate, and sensible making it useful for routine therapeutic monitoring of everolimus. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:99 / 105
页数:7
相关论文
共 23 条
[1]   Therapeutic drug monitoring for sirolimus in whole blood of organ transplants by high-performance liquid chromatography with ultraviolet detection [J].
Campanero, MA ;
Cardenas, E ;
Sádaba, B ;
García-Quetglas, E ;
Muñoz-Juarez, MJ ;
Gil-Aldea, I ;
Pazo, D ;
Azanza, JR ;
Honorato, J .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1031 (1-2) :265-273
[2]   Assessment of sirolimus concentrations in whole blood by high-performance liquid chromatography with ultraviolet detection [J].
Cattaneo, D ;
Perico, N ;
Gaspari, F .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 774 (02) :187-194
[3]   RAD in stable lung and heart/lung transplant recipients: Safety, tolerability, pharmacokinetics, and impact of cystic fibrosis [J].
Doyle, RL ;
Hertz, MI ;
Dunitz, JM ;
Loyd, JE ;
Stecenko, AA ;
Wong, RL ;
Chappell, KA ;
Brazelton, T ;
Kovarik, JM ;
Appeldingmanse, S ;
Dou, L ;
Smith, HT ;
Tudor, D ;
Morris, RE .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2001, 20 (03) :330-339
[4]   Everolimus for the prevention of allograft rejection and vasculopathy in cardiac-transplant recipients [J].
Eisen, HJ ;
Tuzcu, EM ;
Dorent, R ;
Kobashigawa, J ;
Mancini, D ;
Valantine-von Kaeppler, HA ;
Starling, RC ;
Sorensen, K ;
Hummel, M ;
Lind, JM ;
Abeywickrama, KH ;
Bernhardt, P .
NEW ENGLAND JOURNAL OF MEDICINE, 2003, 349 (09) :847-858
[5]   Identification of a new metabolite of macrolide immunosuppressant, like rapamycin and SDZ RAD, using high performance liquid chromatography and electrospray tandem mass spectrometry [J].
Hallensleben, K ;
Raida, M ;
Habermehl, G .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2000, 11 (06) :516-525
[6]   Comparison of the in vitro metabolism of the macrolide immunosuppressants sirolimus and RAD [J].
Jacobsen, W ;
Serkova, N ;
Hausen, B ;
Morris, RE ;
Benet, LZ ;
Christians, U .
TRANSPLANTATION PROCEEDINGS, 2001, 33 (1-2) :514-515
[7]   Proficiency-testing issues relating to sirolimus [J].
Jones, K ;
Johnston, A ;
Holt, DW .
CLINICAL THERAPEUTICS, 2000, 22 :B122-B132
[8]   Therapeutic drug monitoring of sirolimus: correlations with efficacy and toxicity [J].
Kahan, BD ;
Napoli, KL ;
Kelly, PA ;
Podbielski, J ;
Hussein, I ;
Urbauer, DL ;
Katz, SH ;
Van Buren, CT .
CLINICAL TRANSPLANTATION, 2000, 14 (02) :97-109
[9]   RAD in de novo renal transplantation: Comparison of three doses on the incidence and severity of acute rejection [J].
Kahan, BD ;
Kaplan, B ;
Lorber, MI ;
Winkler, M ;
Cambon, N ;
Boger, RS .
TRANSPLANTATION, 2001, 71 (10) :1400-1406
[10]   LC/ESI-MS allows simultaneous and specific quantification of SDZ RAD and cyclosporine, including groups of their metabolites in human blood [J].
Kirchner, GI ;
Vidal, C ;
Winkler, M ;
Mueller, L ;
Jacobsen, W ;
Franzke, A ;
Sewing, KF .
THERAPEUTIC DRUG MONITORING, 1999, 21 (01) :116-122