A precision technology for controlling protein adsorption and cell adhesion in bioMEMS

被引:5
作者
Pan, YV [1 ]
Hanein, Y [1 ]
Leach-Scampavia, D [1 ]
Böhringer, KF [1 ]
Ratner, BD [1 ]
Denton, DD [1 ]
机构
[1] Univ Washington, Seattle, WA 98195 USA
来源
14TH IEEE INTERNATIONAL CONFERENCE ON MICRO ELECTRO MECHANICAL SYSTEMS, TECHNICAL DIGEST | 2001年
关键词
D O I
10.1109/MEMSYS.2001.906571
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A surface coating technique is investigated to enhance device biocompatibility by eliminating bio-fouling, the strong but nonspecific affinity of proteins and cells to attach to surfaces. This coating is a conformal, thin poly(ethylene glycol)-like film deposited in a glow discharge of tetraglyme. Substrates with different chemistries are successfully modified, and exhibit ultralow protein adsorption and cell attachment with the coating. This "stealth" or "non-fouling" coating can also be faithfully patterned using standard photolithography processes. The interaction of proteins and cells with patterned surfaces is limited only to the protein-adhesive domains, thus creating heterogeneous patterns of proteins and cell, cultures on the surface. The potential benefits of our technique to applications such as cell-based assays and micro-electrodes are discussed.
引用
收藏
页码:435 / 438
页数:4
相关论文
共 17 条
  • [1] Andrade JD, 1996, ADV CHEM SER, V248, P51
  • [2] Packaging of physical sensors for aggressive media applications
    Dyrbye, K
    Brown, TR
    Eriksen, GF
    [J]. JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 1996, 6 (01) : 187 - 192
  • [3] INTERACTION OF POLY(ETHYLENE OXIDE) WITH SOLVENTS .1. PREPARATION AND SWELLING OF A CROSSLINKED POLY(ETHYLENE OXIDE) HYDROGEL
    GRAHAM, NB
    NWACHUKU, NE
    WALSH, DJ
    [J]. POLYMER, 1982, 23 (09) : 1345 - 1349
  • [4] HORBETT TA, 1982, BIOMATERIALS INTERFA, P233
  • [5] Kovacs G.T. A., 1994, Enabling Technologies for Cultured Neural Networks, P121, DOI DOI 10.1016/j.jneumeth.2004.03.005
  • [6] Non-invasive measurement of cell membrane associated proton gradients by ion-sensitive field effect transistor arrays for microphysiological and bioelectronical applications
    Lehmann, M
    Baumann, W
    Brischwein, M
    Ehret, R
    Kraus, M
    Schwinde, A
    Bitzenhofer, M
    Freund, I
    Wolf, B
    [J]. BIOSENSORS & BIOELECTRONICS, 2000, 15 (3-4) : 117 - 124
  • [7] GLOW-DISCHARGE PLASMA DEPOSITION OF TETRAETHYLENE GLYCOL DIMETHYL ETHER FOR FOULING-RESISTANT BIOMATERIAL SURFACES
    LOPEZ, GP
    RATNER, BD
    TIDWELL, CD
    HAYCOX, CL
    RAPOZA, RJ
    HORBETT, TA
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1992, 26 (04): : 415 - 439
  • [8] LU HB, 2000, T 6 WORLD BIOM C 5 1, P151
  • [9] An intrinsically protein-resistant surface plasmon resonance biosensor based upon a RF-plasma-deposited thin film
    Mar, MN
    Ratner, BD
    Yee, SS
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 1999, 54 (1-2) : 125 - 131
  • [10] PAN Y, UNPUB