Development of double cylindrical dielectric barrier discharge ion source

被引:23
作者
Hiraoka, Kenzo [1 ]
Ninomiya, Satoshi [2 ]
Chen, Lee Chuin [2 ]
Iwama, Takashi [3 ]
Mandal, Mridul Kanti [1 ]
Suzuki, Hiroaki [4 ]
Ariyada, Osamu [4 ]
Furuya, Hiroko [5 ]
Takekawa, Kenichi [5 ]
机构
[1] Univ Yamanashi, Clean Energy Res Ctr, Yamanashi 4008511, Japan
[2] Univ Yamanashi, Interdisciplinary Grad Sch Med & Engn, Yamanashi 4008511, Japan
[3] Yamanashi Prefectural Ind Technol Ctr, Yamanashi, Japan
[4] ARIOS INC Akishima, Tokyo, Japan
[5] Yamanashi Prefectural Police HQ, Forens Sci Lab, Yamanashi, Japan
基金
日本科学技术振兴机构;
关键词
IONIZATION MASS-SPECTROMETRY; LOW-TEMPERATURE PLASMA; ATMOSPHERIC-PRESSURE; PENNING IONIZATION; HYDROGEN-PEROXIDE; AIR;
D O I
10.1039/c0an00621a
中图分类号
O65 [分析化学];
学科分类号
070302 [分析化学];
摘要
This paper deals with the dielectric barrier discharge (DBD) ion source composed of the outer cylindrical dielectric tube and the inner grounded metallic tube electrode. The sample gas is supplied through the inner ceramic tube. In this ion source, the DBD plasma is localized in the DBD tube so that the sample gases can be ionized just outside of the ceramic tube by the DBD excited helium gas without being exposed in the plasma jet. Besides, ambient air does not take part in the ionization of the sample vapor because ionization takes place inside the DBD ion source. Thus, this method is totally free from contaminants in ambient air. It was found that this ion source is capable of soft, high-sensitivity, and reproducible ionization. Application of this technique to the analysis of methamphetamine, carbaryl and basil leaf was given.
引用
收藏
页码:1210 / 1215
页数:6
相关论文
共 18 条
[1]
Surface desorption atmospheric pressure chemical ionization mass spectrometry for direct ambient sample analysis without toxic chemical contamination [J].
Chen, Huanwen ;
Zheng, Jian ;
Zhang, Xie ;
Luo, Mingbiao ;
Wang, Zhichang ;
Qiao, Xiaolin .
JOURNAL OF MASS SPECTROMETRY, 2007, 42 (08) :1045-1056
[2]
Vapor phase detection of hydrogen peroxide with ambient sampling chemi/chemical ionization mass spectrometry [J].
Chen, Lee Chuin ;
Yu, Zhan ;
Hiraoka, Kenzo .
ANALYTICAL METHODS, 2010, 2 (07) :897-900
[3]
Mass Spectrometric Detection of Gaseous Hydrogen Peroxide in Ambient Air Using Dielectric Barrier Discharge as an Excitation Source [J].
Chen, Lee Chuin ;
Suzuki, Hiroaki ;
Mori, Kunihiko ;
Ariyada, Osamu ;
Hiraoka, Kenzo .
CHEMISTRY LETTERS, 2009, 38 (06) :520-521
[4]
Rapid detection of drugs in biofluids using atmospheric pressure chemi/chemical ionization mass spectrometry [J].
Chen, Lee Chuin ;
Hashimoto, Yutaka ;
Furuya, Hiroko ;
Takekawa, Kenichi ;
Kubota, Takeo ;
Hiraoka, Kenzo .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2009, 23 (03) :333-339
[5]
Versatile new ion source for the analysis of materials in open air under ambient conditions [J].
Cody, RB ;
Laramée, JA ;
Durst, HD .
ANALYTICAL CHEMISTRY, 2005, 77 (08) :2297-2302
[6]
Gross J.H., 2004, MASS SPECTROMETRY
[7]
Low-Temperature Plasma Probe for Ambient Desorption Ionization [J].
Harper, Jason D. ;
Charipar, Nicholas A. ;
Mulligan, Christopher C. ;
Zhang, Xinrong ;
Cooks, R. Graham ;
Ouyang, Zheng .
ANALYTICAL CHEMISTRY, 2008, 80 (23) :9097-9104
[8]
Atmospheric-pressure Penning ionization of aliphatic hydrocarbons [J].
Hiraoka, Kenzo ;
Furuya, Hiroko ;
Kambara, Shizuka ;
Suzuki, Shigeo ;
Hashimoto, Yutaka ;
Takamizawa, Atsushi .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2006, 20 (21) :3213-3222
[9]
NEW PICOGRAM DETECTION SYSTEM BASED ON A MASS-SPECTROMETER WITH AN EXTERNAL IONIZATION SOURCE AT ATMOSPHERIC-PRESSURE [J].
HORNING, EC ;
HORNING, MG ;
CARROLL, DI ;
DZIDIC, I ;
STILLWELL, RN .
ANALYTICAL CHEMISTRY, 1973, 45 (06) :936-943
[10]
Direct analysis of melamine in complex matrices using a handheld mass spectrometer [J].
Huang, Guangming ;
Xu, Wei ;
Visbal-Onufrak, Michelle A. ;
Ouyang, Zheng ;
Cooks, R. Graham .
ANALYST, 2010, 135 (04) :705-711