Direct analysis of melamine in complex matrices using a handheld mass spectrometer

被引:100
作者
Huang, Guangming [2 ]
Xu, Wei [1 ]
Visbal-Onufrak, Michelle A. [3 ]
Ouyang, Zheng [1 ,3 ]
Cooks, R. Graham [2 ]
机构
[1] Purdue Univ, Dept Elect & Comp Engn, W Lafayette, IN 47907 USA
[2] Purdue Univ, Dept Chem, Ctr Analyt Instrumentat Dev, W Lafayette, IN 47907 USA
[3] Purdue Univ, Weldon Sch Biomed Engn, W Lafayette, IN 47907 USA
关键词
RECTILINEAR ION-TRAP; PERFORMANCE LIQUID-CHROMATOGRAPHY; ELECTROSPRAY-IONIZATION; ATMOSPHERIC-PRESSURE; REAL-TIME; DESORPTION-IONIZATION; AMBIENT CONDITIONS; PET FOOD; AIR; RESIDUES;
D O I
10.1039/b923427f
中图分类号
O65 [分析化学];
学科分类号
070302 [分析化学];
摘要
A low temperature plasma ambient ionization source, coupled to a portable mass spectrometer (Mini 10.5), is used for the determination of melamine contamination in whole milk and related materials. Thermally assisted desorption and ionization of the analyte was achieved with the plasma probe. The small size, low power consumption and capability for direct sampling without pretreatment makes plasma ionization an appropriate ionization method for use with a handheld mass spectrometer. The standard discontinuous atmospheric pressure interface used to connect atmospheric pressure ion sources to mass spectrometers (Gao et al., Anal. Chem., 2008, 80, 4026-4032) was modified by using supplementary pumping to increase the ion transfer efficiency. Whole milk, fish, milk powder and other complex matrices spiked with melamine were placed on glass slides close to the vacuum inlet and analyzed without sample pretreatment. Quantitation in complex matrices was achieved using MS/MS of protonated melamine m/z 127 to yield the characteristic fragment ion of m/z 85. Analysis rates of two samples per minute, levels of melamine as low as 250 ng/mL in whole milk (below the regulatory level in the US of 1 ppm (1 mu g/mL) or the European level of 2.5 ppm (mu g/mL)), a linear dynamic range of 0.5-50 mu g/mL and a relative standard deviation of ca. 7.6-16.2% were achieved. The importance of melamine to public health and the prior lack of a rapid, sensitive and yet highly specific field analysis method add to the relevance of this study.
引用
收藏
页码:705 / 711
页数:7
相关论文
共 48 条
[1]
Determination and confirmation of melamine residues in catfish, trout, tilapia, salmon, and shrimp by liquid chromatography with tandem mass spectrometry [J].
Andersen, Wendy C. ;
Turnipseed, Sherri B. ;
Karbiwnyk, Christine M. ;
Clark, Susan B. ;
Madson, Mark R. ;
Gieseker, Charles A. ;
Miller, Ron A. ;
Rummel, Nathan G. ;
Reimschuessel, Renate .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2008, 56 (12) :4340-4347
[2]
Atmospheric pressure chemical ionization source. 2. Desorption-ionization for the direct analysis of solid compounds [J].
Andrade, Francisco J. ;
Shelley, Jacob T. ;
Wetzel, William C. ;
Webb, Michael R. ;
Gamez, Gerardo ;
Ray, Steven J. ;
Hieftje, Gary M. .
ANALYTICAL CHEMISTRY, 2008, 80 (08) :2654-2663
[3]
Determination of urine melamine by validated isotopic ultra-performance liquid chromatography/tandem mass spectrometry [J].
Cheng, Wei-Chih ;
Chen, Shu-Kong ;
Lin, Tien-Jen ;
Wang, I-Jen ;
Kao, Ya-Min ;
Shih, Daniel Yang-Chih .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2009, 23 (12) :1776-1782
[4]
Versatile new ion source for the analysis of materials in open air under ambient conditions [J].
Cody, RB ;
Laramée, JA ;
Durst, HD .
ANALYTICAL CHEMISTRY, 2005, 77 (08) :2297-2302
[5]
Observation of Molecular Ions and Analysis of Nonpolar Compounds with the Direct Analysis in Real Time Ion Source [J].
Cody, Robert B. .
ANALYTICAL CHEMISTRY, 2009, 81 (03) :1101-1107
[6]
Analysis of melamine resins by capillary zone electrophoresis with electrospray ionization-mass spectrometric detection [J].
Cook, HA ;
Klampfl, CW ;
Buchberger, W .
ELECTROPHORESIS, 2005, 26 (7-8) :1576-1583
[7]
Ambient mass spectrometry [J].
Cooks, RG ;
Ouyang, Z ;
Takats, Z ;
Wiseman, JM .
SCIENCE, 2006, 311 (5767) :1566-1570
[8]
Ambient aerodynamic ionization source for remote analyte sampling and mass spectrometric analysis [J].
Dixon, R. Brent ;
Sampson, Jason S. ;
Hawkridge, Adam M. ;
Muddiman, David C. .
ANALYTICAL CHEMISTRY, 2008, 80 (13) :5266-5271
[9]
Remote mass spectrometric sampling of electrospray- and desorption electrospra-generated ions using an air ejector [J].
Dixon, R. Brent ;
Bereman, Michael S. ;
Muddiman, David C. ;
Hawkridge, Adam M. .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2007, 18 (10) :1844-1847
[10]
Identification and characterization of toxicity of contaminants in pet food leading to an outbreak of renal toxicity in cats and dogs [J].
Dobson, Roy L. M. ;
Motlagh, Safa ;
Quijano, Mike ;
Cambron, R. Thomas ;
Baker, Timothy R. ;
Pullen, Aletha M. ;
Regg, Brian T. ;
Bigalow-Kern, Adrienne S. ;
Vennard, Thomas ;
Fix, Andrew ;
Reimschuessel, Renate ;
Overmann, Gary ;
Shan, Yuching ;
Daston, George P. .
TOXICOLOGICAL SCIENCES, 2008, 106 (01) :251-262