Is adjunctive balloon postdilatation necessary after coronary stent deployment? Final results from the POSTIT trial

被引:54
作者
Brodie, BR
Cooper, C
Jones, M
Fitzgerald, P
Cummins, F
机构
[1] LeBauer Cardiovasc Res Fdn, Greensboro, NC USA
[2] Med Coll Ohio, Toledo, OH 43699 USA
[3] Cent Baptist Hosp, Lexington, KY USA
[4] Stanford Univ, Med Ctr, Stanford, CA 94305 USA
[5] St Lukes Hosp, Milwaukee, WI USA
关键词
stent; intravascular ultrasound; coronary intervention;
D O I
10.1002/ccd.10474
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Early-generation balloon-expandable stents required postdilatation with noncompliant balloons at high pressure to optimize stent deployment. The need for adjunctive balloon postdilatation with modern stent delivery systems is unknown. Patients undergoing elective stenting were randomized to Boston Scientific NIR, Guidant Tri-Star/Tetra, and Medtronic AVE S670 stents. The primary endpoint was optimum stent deployment defined as a minimal stent diameter (MSD) greater than or equal to 90% of the average reference lumen diameter assessed by intravascular ultrasound (IVUS) performed immediately following stent deployment. If, by operator assessment, the primary endpoint was not achieved with the stent delivery system, adjunctive postdilatation with noncompliant balloons was performed. Of 256 patients with IVUS studies adequate for core laboratory analysis, only 29% achieved optimum stent deployment with the stent delivery system. None of the baseline clinical or angiographic variables predicted optimum stent deployment. Of the procedural variables, the type of stent and nominal stent size were not predictors, but higher deployment pressures were associated with a higher frequency of optimum stent deployment (< 12 atm 14% vs. greater than or equal to 12 atm 36%; P = 0.007). The inability to achieve optimum stent deployment was not due to undersizing the stent delivery balloon, but rather to an inability of the stent delivery balloon to expand fully the stent to nominal size. In patients who underwent postdilatation, the frequency of achieving optimum stent deployment increased from 21% to 42%, minimal stent area increased from 6.6 +/- 2.2 to 7.8 +/- 2.3 mm(2), and MSD increased from 2.6 +/- 0.5 to 2.8 +/- 0.4 mm. These data stress the continued need for adjunctive balloon postdilatation with modern stent delivery systems. (C) 2003 Wiley-Liss, Inc.
引用
收藏
页码:184 / 192
页数:9
相关论文
共 12 条
[1]   INTRACORONARY STENTING WITHOUT ANTICOAGULATION ACCOMPLISHED WITH INTRAVASCULAR ULTRASOUND GUIDANCE [J].
COLOMBO, A ;
HALL, P ;
NAKAMURA, S ;
ALMAGOR, Y ;
MAIELLO, L ;
MARTINI, G ;
GAGLIONE, A ;
GOLDBERG, SL ;
TOBIS, JM .
CIRCULATION, 1995, 91 (06) :1676-1688
[2]   Reference chart derived from post-stent-implantation intravascular ultrasound predictors of 6-month expected restenosis on quantitative coronary angiography [J].
de Feyter, PJ ;
Kay, P ;
Disco, C ;
Serruys, PW .
CIRCULATION, 1999, 100 (17) :1777-1783
[3]   Intravascular ultrasound-guided optimized stent deployment - Immediate and 6 months clinical and angiographic results from the Multicenter Ultrasound Stenting in Coronaries Study (MUSIC Study) [J].
de Jaegere, P ;
Mudra, H ;
Figulla, H ;
Almagor, Y ;
Doucet, S ;
Penn, I ;
Colombo, A ;
Hamm, C ;
Bartorelli, A ;
Rothman, M ;
Nobuyoshi, M ;
Yamaguchi, T ;
Voudris, V ;
DiMario, C ;
Makovski, S ;
Hausmann, D ;
Rowe, S ;
Rabinovich, S ;
Sunamura, M ;
van Es, GA .
EUROPEAN HEART JOURNAL, 1998, 19 (08) :1214-1223
[4]  
Fitzgerald PJ, 2000, CIRCULATION, V102, P523
[5]   Utilization of the coronary balloon-expandable coil stent without anticoagulation or intravascular ultrasound [J].
Goods, CM ;
AlShaibi, KF ;
Yadav, SS ;
Liu, MW ;
Negus, BH ;
Iyer, SS ;
Dean, LS ;
Jain, SP ;
Baxley, WA ;
Parks, JM ;
Sutor, RJ ;
Roubin, GS .
CIRCULATION, 1996, 93 (10) :1803-1808
[6]   Overestimation of stent delivery balloon diameters by manufacturers' compliance tables: A quantitative coronary analysis of duet and NIR stent implantation [J].
Hehrlein, C ;
DeVries, JJ ;
Wood, TA ;
Haller, SD ;
Arab, A ;
Kloostra, AC ;
Lauer, MA ;
Fischell, TA .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2001, 53 (04) :474-478
[7]   Intravascular ultrasound predictors of angiographic restenosis in lesions treated with Palmaz-Schatz stents [J].
Hoffmann, R ;
Mintz, GS ;
Mehran, R ;
Pichard, AD ;
Kent, KM ;
Satler, LF ;
Popma, JJ ;
Wu, HS ;
Leon, MB .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 31 (01) :43-49
[8]   Efficacy of postdeployment balloon dilatation for current generation stents as assessed by intravascular ultrasound [J].
Hur, SH ;
Kitamura, K ;
Morino, Y ;
Honda, Y ;
Jones, M ;
Korr, KS ;
Reen, B ;
Cooper, CJ ;
Niess, GS ;
Christie, L ;
Corey, W ;
Messenger, J ;
Yock, PG ;
Cummins, F ;
Fitzgerald, PJ .
AMERICAN JOURNAL OF CARDIOLOGY, 2001, 88 (10) :1114-1119
[9]   Does the specific intravascular ultrasound criterion used to optimize stent expansion have an impact on the probability of stent restenosis? [J].
Moussa, I ;
Moses, J ;
Di Mario, C ;
Albiero, R ;
De Gregorio, J ;
Adamian, M ;
Di Francesco, L ;
Colombo, A .
AMERICAN JOURNAL OF CARDIOLOGY, 1999, 83 (07) :1012-1017
[10]  
Roberts DK, 2000, CIRCULATION, V102, P547