Minimizing analyte electrolysis in an electrospray emitter

被引:44
作者
Kertesz, V [1 ]
Van Berkel, GJ [1 ]
机构
[1] Oak Ridge Natl Lab, Div Chem & Analyt Sci, Oak Ridge, TN 37381 USA
来源
JOURNAL OF MASS SPECTROMETRY | 2001年 / 36卷 / 02期
关键词
electrospray mass spectrometry; electrolysis; oxidation; stainless-steel emitter; platinum emitter; fused-silica emitter;
D O I
10.1002/jms.122
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The electrospray (ES) ion source is a controlled-current electrolytic now cell. Electrolytic reactions in the ES emitter capillary are continually ongoing to sustain the production of charged droplets and ultimately gas-phase ions from this device. Under certain circumstances, the analytes under study may be directly involved in these electrolytic processes. It is demonstrated that a simple means to minimize analyte electrolysis is to exchange the normal metal emitter capillary of commercial ES sources with one made of fused silica. This change is shown to provide an ES mass spectrometric system of similar performance in terms of gas-phase ion signal generated for non-electroactive analytes and also assures minimal oxidation of electroactive analytes even at low (2.0 mul min(-1)) solution flow-rates and high (millimolar) solution electrolyte concentrations.
引用
收藏
页码:204 / 210
页数:7
相关论文
共 24 条
[1]  
Cole R.B., 1997, Electrospray Ionization Mass Spectrometry
[2]   Electrochemical polymerization of aniline investigated using on line electrochemistry/electrospray mass spectrometry [J].
Deng, HT ;
Van Berkel, GJ .
ANALYTICAL CHEMISTRY, 1999, 71 (19) :4284-4293
[3]  
Deng HT, 1999, ELECTROANAL, V11, P857, DOI 10.1002/(SICI)1521-4109(199908)11:12<857::AID-ELAN857>3.0.CO
[4]  
2-1
[5]   Electrochemically modulated liquid chromatography coupled on-line with electrospray mass spectrometry [J].
Deng, HT ;
Van Berkel, OJ .
ANALYTICAL CHEMISTRY, 2000, 72 (11) :2641-2647
[6]   Electrical equivalence of electrospray ionization with conducting and nonconducting needles [J].
Jackson, GS ;
Enke, CG .
ANALYTICAL CHEMISTRY, 1999, 71 (17) :3777-3784
[7]  
Karancsi T, 1997, RAPID COMMUN MASS SP, V11, P81, DOI 10.1002/(SICI)1097-0231(19970115)11:1<81::AID-RCM803>3.0.CO
[8]  
2-W
[9]   Multiply charged redox-active oligomers in the gas phase: Electrolytic electrospray ionization mass spectrometry of metallocenes [J].
McCarley, TD ;
Lufaso, MW ;
Curtin, LS ;
McCarley, RL .
JOURNAL OF PHYSICAL CHEMISTRY B, 1998, 102 (49) :10078-10086
[10]  
SENKO M, 2000, ISOPRO 3 0 THIS ISOT