Evaluation of coronary artery lumen diameter with 16-slice multidetector-row computed tomography

被引:10
作者
Yamada, M
Jinzaki, M
Kuribayashi, S
Sato, K
Tanami, Y
Yun, S
Sasaki, K
机构
[1] Keio Univ, Sch Med, Cardiovasc Imaging Lab, Shinjuku Ku, Tokyo 1608582, Japan
[2] Keio Univ, Sch Med, Dept Diagnost Radiol, Tokyo 108, Japan
[3] GE Med Syst, Tokyo, Japan
关键词
coronary artery; lumen diameter; multidetector-row computed tomography;
D O I
10.1253/circj.69.1230
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background When using 16-slice multidetector-row computed tomography (MDCT) to detect coronary artery stenosis, coronary arteries measuring 1.5 mm or larger in lumen diameter are usually evaluated. The purpose of this study was to investigate the frequency of the visualized lumen in each coronary artery segment measuring more than 1.5 mm in diameter. Methods and Results Electrocardiographic-gated 16-slice MDCT was used to scan 20 patients after administration of nitroglycerin. The luminal diameter of each coronary artery segment was measured on cross-sectional images using a caliper method. The frequency of the visualized lumen of each coronary artery segment measuring larger than 1.5 rum in diameter was as follows: #1: 100%, #2: 100%, #3: 100%, #4PD: 85%, #4AV: 80%, #5: 100%, #6: 100%, #7: 100%, #8: 90%, #9: 85%, #10: 40%, #11: 100%, #12: 65%, #13: 100%, #14: 80%. Averaged lumen diameter standard deviation (mm) larger than 1.5 mm in all patients was calculated as follows: #1: 3.8 +/- 0.70, #2: 3.5 +/- 0.69, #3: 3.2 +/- 0.82, #5: 4.2 +/- 1.04, #6: 3.4 +/- 0.79, #7: 2.9 +/- 0.62, #11: 2.9 +/- 0.69, #13: 2.6 +/- 0.57. Conclusion Luminal diameter larger than 1.5 mm of each coronary artery segment can be assessed in most cases by 16-slice MDCT.
引用
收藏
页码:1230 / 1232
页数:3
相关论文
共 18 条
[1]   Assessment of coronary remodeling in stenotic and nonstenotic coronary atherosclerotic lesions by multidetector spiral computed tomography [J].
Achenbach, S ;
Ropers, D ;
Hofmann, U ;
MacNeill, B ;
Baum, U ;
Pohle, K ;
Brady, TJ ;
Pomerantsev, E ;
Ludwig, J ;
Flachskampf, FA ;
Wicky, S ;
Jang, IK ;
Daniel, WG .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (05) :842-847
[2]  
Achenbach S, 2001, CIRCULATION, V103, P2535
[3]  
Austen W G, 1975, Circulation, V51, P5
[4]   Current development of cardiac imaging with multidetector-row CT [J].
Becker, CR ;
Ohnesorge, BM ;
Schoepf, UJ ;
Reiser, MF .
EUROPEAN JOURNAL OF RADIOLOGY, 2000, 36 (02) :97-103
[5]   Detection of coronary artery stenoses with multislice helical CT angiography [J].
Becker, CR ;
Knez, A ;
Leber, A ;
Treede, H ;
Ohnesorge, B ;
Schoepf, UJ ;
Reiser, MF .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2002, 26 (05) :750-755
[6]   LUMEN DIAMETER OF NORMAL HUMAN CORONARY-ARTERIES - INFLUENCE OF AGE, SEX, ANATOMIC VARIATION, AND LEFT-VENTRICULAR HYPERTROPHY OR DILATION [J].
DODGE, JT ;
BROWN, BG ;
BOLSON, EL ;
DODGE, HT .
CIRCULATION, 1992, 86 (01) :232-246
[7]   Evaluation of plaque texture by means of multislice computed tomography in patients with acute coronary syndrome and stable angina [J].
Inoue, F ;
Sato, Y ;
Matsumoto, N ;
Tani, S ;
Uchiyama, T .
CIRCULATION JOURNAL, 2004, 68 (09) :840-844
[8]   Non-invasive coronary angiography with high resolution multidetector-row computed tomography - Results in 102 patients [J].
Kopp, AF ;
Schroeder, S ;
Kuettner, A ;
Baumbach, A ;
Georg, C ;
Kuzo, R ;
Heuschmid, M ;
Ohnesorge, B ;
Karsch, KR ;
Claussen, CD .
EUROPEAN HEART JOURNAL, 2002, 23 (21) :1714-1725
[9]   Diagnostic accuracy of multidetector computed tomography coronary angiography in with angiographically proven coronary artery disease patients [J].
Kuettner, A ;
Kopp, AF ;
Schroeder, S ;
Rieger, T ;
Brunn, J ;
Meisner, C ;
Heuschmid, M ;
Trabold, T ;
Burgstahler, C ;
Martensen, J ;
Schoebel, W ;
Selbmann, HK ;
Claussen, CD .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (05) :831-839
[10]  
Maintz D, 2003, INVEST RADIOL, V38, P790, DOI 10.1097/01.rli.0000086495.96457.54