Non-invasive coronary angiography with high resolution multidetector-row computed tomography - Results in 102 patients

被引:186
作者
Kopp, AF
Schroeder, S
Kuettner, A
Baumbach, A
Georg, C
Kuzo, R
Heuschmid, M
Ohnesorge, B
Karsch, KR
Claussen, CD
机构
[1] Univ Tubingen, Dept Diagnost Radiol, D-72076 Tubingen, Germany
[2] Univ Tubingen, Div Cardiol, Dept Internal Med, D-72076 Tubingen, Germany
[3] Univ Bristol, Inst Heart, Dept Cardiol, Bristol BS8 1TH, Avon, England
[4] Mayo Clin Jacksonville, Jacksonville, FL 32224 USA
关键词
multidetector-row computed tomography (MDCT); coronary artery disease (CAD); computed tomography angiography (CTA); image reconstruction;
D O I
10.1053/euhj.2002.3264
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims A new generation of multidetector-row CT (MDCT) scanners allows complete coronary coverage using retrospective ECG gating and 1 mm slices. The purpose of this study was to investigate the potential of high resolution MDCT angiography with retrospective gating for detection of coronary artery stenoses. Methods and Results A total of 102 patients underwent both conventional and MDCT coronary angiography. After intravenous injection of a non-ionic contrast medium the entire heart was scanned within a single breath hold using 1 mm slices. All MDCT data sets were reconstructed with retrospective gating at 20% to 80% in increments of 10% relative to the cardiac cycle. Two blinded independent reviewers analysed image quality for segments 1-4 (right coronary artery), 5-8 (left main, left anterior descending), and 11, 12 (left circumflex). These segments were evaluated for the presence or absence of significant (greater than or equal to 50%) stenoses. The results were compared with those of invasive coronary angiography in a blinded fashion. Overall sensitivity for the detection of significant stenoses (greater than or equal to 50%) were 0.86 (reader 1) and 0.93 (reader 2), specificity 0.96 (reader 1) and 0.97 (reader 2), negative predictive value 0.98 (reader 1) and 0.99 (reader 2). Conclusions High resolution MDCT angiography with retrospective gating permits the non-invasive detection of coronary artery stenoses with high accuracy if image quality is optimized for each of the three major coronary arteries.
引用
收藏
页码:1714 / 1725
页数:12
相关论文
共 17 条
[1]   Value of electron-beam computed tomography for the noninvasive detection of high-grade coronary-artery stenoses and occlusions [J].
Achenbach, S ;
Moshage, W ;
Ropers, D ;
Nossen, J ;
Daniel, WG .
NEW ENGLAND JOURNAL OF MEDICINE, 1998, 339 (27) :1964-1971
[2]  
Achenbach S, 2001, CIRCULATION, V103, P2535
[3]   In-plane coronary arterial motion velocity: Measurement with electron-beam CT [J].
Achenbach, S ;
Ropers, D ;
Holle, J ;
Muschiol, G ;
Daniel, WG ;
Moshage, W .
RADIOLOGY, 2000, 216 (02) :457-463
[4]  
*AM HEART ASS COMM, 1999, CIRCULATION, V51, P7
[5]  
Flohr TG, 2000, RADIOLOGY, V217, P438
[6]   Subsecond multi-slice computed tomography: basics and applications [J].
Klingenbeck-Regn, K ;
Schaller, S ;
Flohr, T ;
Ohnesorge, B ;
Kopp, AF ;
Baum, U .
EUROPEAN JOURNAL OF RADIOLOGY, 1999, 31 (02) :110-124
[7]  
Kopp AF, 1999, RADIOLOGY, V213P, P435
[8]  
KOPP AF, 2000, ROFO FORTSCHR RONTG, V172, P1
[9]  
Kwok B. W. K., 2000, SMJ Singapore Medical Journal, V41, P604
[10]  
Mannebach H, 2001, Z KARDIOL, V90, P665, DOI 10.1007/s003920170115