A novel high-throughput automated chip-based nanoelectrospray tandem mass spectrometric method for PAMPA sample analysis

被引:40
作者
Balimane, PV
Pace, E
Chong, S
Zhu, MS
Jemal, M
Van Pelt, CK
机构
[1] Bristol Myers Squibb, Princeton, NJ 08543 USA
[2] Advion Biosci, Ithaca, NY USA
关键词
permeability-screening; nanoelectrospray analysis; PAMPA permeability; drug discovery; high-throughput screening; HPLC; LC/MS;
D O I
10.1016/j.jpba.2005.03.043
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Parallel artificial membrane permeability assay (PAMPA) has recently gained popularity as a novel, high-throughput assay capable of rapidly screening compounds for their permeability characteristics in early drug discovery. The analytical techniques typically used for PAMPA sample analysis are HPLC-UV, LUMS or more recently UV-plate reader. The LC techniques, though sturdy and accurate, are often labor and time intensive and are not ideal for high-throughput. On the other hand, UV-plate reader technique is amenable to high-throughput but is not sensitive enough to detect the lower concentrations that are often encountered in early drug discovery work. This article investigates a novel analytical method, a chip-based automated nanoelectrospray mass spectrometric method for its ability to rapidly analyze PAMPA permeability samples. The utility and advantages of this novel analytical method is demonstrated by comparing PAMPA permeability values obtained from nanoelectrospray to those from conventional analytical methods. Ten marketed drugs having a broad range of structural space, physico-chemical properties and extent of intestinal absorption were selected as test compounds for this investigation'. PAMPA permeability and recovery experiments were conducted with model compounds followed by analysis by UV-plate reader, UV-HPLC as well as the automated nanoelectrospray technique (nanoESI-MS/MS). There was a very good correlation (r(2) > 0.9) between the results obtained using nanoelectrospray and the other analytical techniques tested. Moreover, the nanoelectrospray approach presented several advantages over the standard techniques such as higher sensitivity and ability to detect individual compounds in cassette studies, making it an attractive high-throughput analytical technique. Thus, it has been demonstrated that nanoelectrospray analysis provides a highly efficient and accurate analytical methodology to analyze PAMPA samples generated in early drug discovery. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:8 / 16
页数:9
相关论文
共 35 条
[1]   Development of a 7-day, 96-well Caco-2 permeability assay with high-throughput direct UV compound analysis [J].
Alsenz, J ;
Haenel, E .
PHARMACEUTICAL RESEARCH, 2003, 20 (12) :1961-1969
[2]  
ARTURSSON P, 1991, CRIT REV THER DRUG, V8, P305
[3]  
Avdeef Alex, 2001, Current Topics in Medicinal Chemistry, V1, P277, DOI 10.2174/1568026013395100
[4]   Utility of 96 well Caco-2 cell system for increased throughput of P-gp screening in drug discovery [J].
Balimane, PV ;
Patel, K ;
Marino, A ;
Chong, SH .
EUROPEAN JOURNAL OF PHARMACEUTICS AND BIOPHARMACEUTICS, 2004, 58 (01) :99-105
[5]   Current methodologies used for evaluation of intestinal permeability and absorption [J].
Balimane, PV ;
Chong, SH ;
Morrison, RA .
JOURNAL OF PHARMACOLOGICAL AND TOXICOLOGICAL METHODS, 2000, 44 (01) :301-312
[6]   Evaluation of Biocoat® intestinal epithelium differentiation environment (3-day cultured Caco-2 cells) as an absorption screening model with improved productivity [J].
Chong, SH ;
Dando, SA ;
Morrison, RA .
PHARMACEUTICAL RESEARCH, 1997, 14 (12) :1835-1837
[7]   In vitro permeability through Caco-2 cells is not quantitatively predictive of in vivo absorption for peptide-like drugs absorbed via the dipeptide transporter system [J].
Chong, SH ;
Dando, SA ;
Soucek, KM ;
Morrison, RA .
PHARMACEUTICAL RESEARCH, 1996, 13 (01) :120-123
[8]  
Collett A, 1999, J PHARMACOL EXP THER, V288, P171
[9]   Regional intestinal permeability in rats of compounds with different physicochemical properties and transport mechanisms [J].
Fagerholm, U ;
Lindahl, A ;
Lennernas, H .
JOURNAL OF PHARMACY AND PHARMACOLOGY, 1997, 49 (07) :687-690
[10]   Higher-throughput screening for Caco-2 permeability utilizing a multiple sprayer liquid chromatography/tandem mass spectrometry system [J].
Fung, EN ;
Chu, IH ;
Li, C ;
Liu, TT ;
Soares, A ;
Morrison, R ;
Nomeir, AA .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2003, 17 (18) :2147-2152