Extension of the dynamic range of flame atomic absorption spectrometry using flow injection analysis with variable-volume dilution chambers

被引:9
作者
ElAzouzi, H [1 ]
PerezJordan, MY [1 ]
Salvador, A [1 ]
delaGuardia, M [1 ]
机构
[1] UNIV VALENCIA,DEPT ANALYT CHEM,E-46100 BURJASSOT,VALENCIA,SPAIN
关键词
copper; flame atomic absorption spectrometry; flow injection analysis; on-line dilution of samples;
D O I
10.1016/S0584-8547(96)01534-0
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
A simple and inexpensive procedure is proposed for the extension of the dynamic range of flame atomic absorption spectrometry measurements using on-line dilution. The proposed methodology is based on the use of a manifold with two coupled dilution chambers and a zone injection system. The samples are prediluted in a closed system which includes a variable-volume mixing chamber (10-120 ml) and two injection valves. The samples are injected through one of these valves, and the other is employed to take 100 mu l of prediluted samples which are then passed through a new dilution chamber (volume 1-10 ml) and aspirated by the nebulizer of the instrument. A third injection valve mounted in the last part of the manifold is used for the direct injection of diluted standard solutions. Various dilution factors are obtained, ranging from 2 to 130 000 times, thus extending the analytical range of copper determination to more than 100 000 mg l(-1).
引用
收藏
页码:1747 / 1752
页数:6
相关论文
共 29 条
[11]   EXPANSION OF DYNAMIC-RANGE OF FLAME ATOMIC-ABSORPTION SPECTROMETRY BY AN EFFICIENT FLOW-INJECTION DILUTION SYSTEM BASED ON DISPERSION OF MICROLITER-VOLUME SAMPLES [J].
FANG, ZL ;
WELZ, B ;
SPERLING, M .
ANALYTICAL CHEMISTRY, 1993, 65 (13) :1682-1688
[12]   EXTENDING ONLINE DILUTION STEADY-STATE CONCENTRATION RANGE BY MODIFICATION OF THE MERGING STREAM AND TANDEM INJECTION CONTINUOUS-FLOW METHODS [J].
ISRAEL, Y ;
BARNES, RM .
ANALYST, 1991, 116 (05) :489-495
[13]  
Lopez-Garcia I, 1994, J ANAL ATOM SPECTROM, V9, P553
[14]  
LOPEZGARCIA I, 1994, J ANAL ATOM SPECTROM, V9, P1167
[15]  
LOPEZGARCIA I, 1992, J ANAL ATOM SPECTROM, V7, P1291
[16]   FLAME ATOMIC-ABSORPTION ANALYSIS OF GOLD IN JEWELRY SAMPLES [J].
MAURI, AR ;
HUERTA, E ;
DELAGUARDIA, M .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1990, 338 (06) :699-702
[17]  
Mindel B. D., 1981, Laboratory Practice, V30, P719
[18]   ZONE-SAMPLING PROCESSES IN FLOW-INJECTION ANALYSIS [J].
REIS, BF ;
JACINTHO, AO ;
MORTATTI, J ;
KRUG, FJ ;
ZAGATTO, EAG ;
BERGAMIN, H ;
PESSENDA, LCR .
ANALYTICA CHIMICA ACTA, 1981, 123 (JAN) :221-228
[19]  
REIS BF, 1992, J ANAL ATOM SPECTROM, V7, P865
[20]   DIRECT DETERMINATION OF CALCIUM AND MAGNESIUM IN SERUM USING FLOW-INJECTION ANALYSIS AND ATOMIC-ABSORPTION SPECTROSCOPY [J].
ROCKS, BF ;
SHERWOOD, RA ;
RILEY, C .
ANNALS OF CLINICAL BIOCHEMISTRY, 1984, 21 (JAN) :51-56