Real-time three-dimensional color Doppler echocardiography for characterizing the spatial velocity distribution and quantifying the peak flow rate in the left ventricular outflow tract

被引:41
作者
Tsujino, H
Jones, M
Shiota, T
Qin, JX
Greenberg, NL
Cardon, LA
Morehead, AJ
Zetts, AD
Travaglini, A
Bauer, F
Panza, JA
Thomas, JD
机构
[1] Cleveland Clin Fdn, Dept Cardiol F15, Cardiovasc Imaging Ctr, Cleveland, OH 44195 USA
[2] NHLBI, NIH, Bethesda, MD 20892 USA
基金
美国国家航空航天局;
关键词
3-D echocardiography; color Doppler; Doppler ultrasound; hemodynamics;
D O I
10.1016/S0301-5629(00)00270-2
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Quantification of flow with pulsed-wave Doppler assumes a "flat" velocity profile in the left ventricular outflow tract (LVOT), which observation refutes. Recent development of real-time, three-dimensional (3-D) color Doppler allows one to obtain an entire cross-sectional velocity distribution of the LVOT, which is not possible using conventional 2-D echo. In an animal experiment, the cross-sectional color Doppler images of the LVOT at peak systole were derived and digitally transferred to a computer to visualize and quantify spatial velocity distributions and peak flow rates. Markedly skewed profiles, with higher velocities toward the septum, were consistently observed. Reference peak flow rates by electromagnetic flow meter correlated well with 3-D peak flow rates (r = 0.94), but with an anticipated underestimation. Real-time 3-D color Doppler echocardiography was capable of determining cross-sectional velocity distributions and peak flow rates, demonstrating the utility of this new method for better understanding and quantifying blood flow phenomena. (E-mail: shiotat@ccf.org) (C) 2001 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:69 / 74
页数:6
相关论文
共 26 条
[1]   Quantification of aortic regurgitant volume by a newly developed automated cardiac flow measurement method: An in vitro study [J].
Aida, S ;
Shiota, T ;
Tsujino, H ;
Sahn, DJ .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 1998, 11 (09) :874-881
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]   Increased accuracy of echocardiographic measurement of flow using automated spherical integration of multiple plane velocity vectors [J].
Brandberg, J ;
Janerot-Sjöberg, B ;
Ask, P .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1999, 25 (02) :249-257
[4]  
CAMP GV, 1998, J AM SOC ECHOCARDIOG, V11, P643
[5]   INFLUENCE OF SAMPLING SITE AND FLOW AREA ON CARDIAC-OUTPUT MEASUREMENTS BY DOPPLER ECHOCARDIOGRAPHY [J].
DITTMANN, H ;
VOELKER, W ;
KARSCH, KR ;
SEIPEL, L .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1987, 10 (04) :818-823
[6]   THE EFFECT OF VARIATIONS ON PULSED DOPPLER SAMPLING SITE ON CALCULATION OF CARDIAC-OUTPUT - AN EXPERIMENTAL-STUDY IN OPEN-CHEST DOGS [J].
FISHER, DC ;
SAHN, DJ ;
FRIEDMAN, MJ ;
LARSON, D ;
VALDESCRUZ, LM ;
HOROWITZ, S ;
GOLDBERG, SJ ;
ALLEN, HD .
CIRCULATION, 1983, 67 (02) :370-376
[7]   Automated assessment of mitral regurgitant volume and regurgitant fraction by a newly developed digital color Doppler velocity profile integration method [J].
Hozumi, T ;
Yoshida, K ;
Akasaka, T ;
Takagi, T ;
Yamamuro, A ;
Yagi, T ;
Yoshikawa, J .
AMERICAN JOURNAL OF CARDIOLOGY, 1997, 80 (10) :1325-1330
[8]   NON-INVASIVE DOPPLER DETERMINATION OF CARDIAC-OUTPUT IN MAN - CLINICAL VALIDATION [J].
HUNTSMAN, LL ;
STEWART, DK ;
BARNES, SR ;
FRANKLIN, SB ;
COLOCOUSIS, JS ;
HESSEL, EA .
CIRCULATION, 1983, 67 (03) :593-602
[9]  
Hunziker Patrick R., 1999, Journal of the American College of Cardiology, V33, p425A
[10]  
Irvine T, 1998, CIRCULATION, V98, P715