Uncemented Total Knee Arthroplasty: 2-Year Follow-Up of 100 Knees With a Rotating Platform, Cruciate-Retaining Design

被引:11
作者
Signorelli, Joseph J. [1 ]
Bernini, Philip M. [1 ]
Shirreffs, Thomas G. [1 ]
机构
[1] Dartmouth Hitchcock Dept Orthoped Surg, Lebanon, NH 03756 USA
关键词
uncemented; cementless; total knee arthroplasty; implant fixation; CEMENTLESS FIXATION; TIBIAL COMPONENTS; SURVIVORSHIP; REPLACEMENTS; POLYETHYLENE; BEARING;
D O I
10.1016/j.arth.2010.01.094
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
100224 [整形外科学];
摘要
Review of the literature shows mixed results regarding uncemented total knee arthroplasty (TKA). To our knowledge, there are no reports of results for uncemented TKA that incorporates a cruciate-retaining and rotating platform design. It is theorized that these design features could decrease the stress at the bone-implant interface. This study reports results on 100 uncemented TKAs at a minimum of 2-year follow-up. Average Knee Society clinical score improved from 52.9 to 95.1; average Knee Society functional score improved from 60.5 to 82.0. Ninety-eight percent of patients had excellent and 2% had good results based on Knee Society scores. There was 99% implant survival; 1 patient required revision of a loose tibial component after a motor vehicle accident. The promising short-term results support the continued use of this implant and suggest a prospective randomized study comparing cemented vs uncemented TKA of this design is warranted.
引用
收藏
页码:427 / 431
页数:5
相关论文
共 21 条
[1]
Baldwin JL, 1996, ORTHOPEDICS, V19, P123
[2]
Berger RA, 2001, CLIN ORTHOP RELAT R, P58
[3]
Buechel FF, 2001, CLIN ORTHOP RELAT R, P41
[4]
Cemented tibial component fixation performs better than cementless fixation -: A randomized radiostereometric study comparing porous-coated, hydroxyapatite-coated and cemented tibial components over 5 years [J].
Carlsson, Å ;
Björkman, A ;
Besjakov, J ;
Önsten, I .
ACTA ORTHOPAEDICA, 2005, 76 (03) :362-369
[5]
Duffy GP, 1998, CLIN ORTHOP RELAT R, P66
[6]
Fixation of a Trabecular Metal Knee Arthroplasty Component A Prospective Randomized Study [J].
Dunbar, M. J. ;
Wilson, D. A. J. ;
Hennigar, A. W. ;
Amirault, J. D. ;
Gross, M. ;
Reardon, G. P. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2009, 91A (07) :1578-1586
[7]
Font-Rodriguez DE, 1997, CLIN ORTHOP RELAT R, P79
[8]
Fixation of the NexGen HA-TCP-coated cementless, screwless total knee arthroplasty - Comparison with conventional cementless total knee arthroplasty of the same type [J].
Gejo, R ;
Akizuki, S ;
Takizawa, T .
JOURNAL OF ARTHROPLASTY, 2002, 17 (04) :449-456
[9]
Low contact stress mobile bearing total knee arthroplasty - Results at 5 to 13 Years [J].
Hartford, JM ;
Hunt, T ;
Kaufer, H .
JOURNAL OF ARTHROPLASTY, 2001, 16 (08) :977-983
[10]
Cementless total knee arthroplasty in patients 50 years or younger [J].
Hofmann, AA ;
Heithoff, SM ;
Camargo, M .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2002, (404) :102-107