Optimized 124I PET dosimetry protocol for radioiodine therapy of differentiated thyroid cancer

被引:109
作者
Jentzen, Walter [1 ]
Freudenberg, Lutz [1 ]
Eising, Emst G. [1 ]
Sormenschein, Wilfried [1 ]
Knust, Jochen [1 ]
Bockisch, Andreas [1 ]
机构
[1] Univ Duisburg Essen, Klin Nukl Med, D-45122 Essen, Germany
关键词
PET; radionuclide therapy; dosimetry; iodine-124; differentiated thyroid cancer;
D O I
10.2967/jnumed.107.047159
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Iodine kinetics and lesion dose per administered I-131 activity (LDpA) of differentiated thyroid cancer metastases were determined using I-124 PET. These data were analyzed to derive an optimized dosimetry protocol. Methods: We evaluated the time-activity-concentration curves of 37 lesions in 17 patients who had undergone thyroidectomies. LDpA determination involved I-124 PET images acquired at 4, 24, 48, 72, and 96 h after intake of a capsule containing 20-40 MBq of I-124. A combination of a linear and a monoexponential or a monoexponential function only parameterized the time-activity-concentration curves. The LDpAs, calculated using data from all 5 PET time points, served as reference. The lesions were classified into 3 groups, according to potential for cure with I-131 therapy: low (<= 5 Gy GBq(-1); n = 14), medium (between 5 and 10 Gy GBq(-1); n = 9), or high LDpAs (>10 Gy GBq(-1); n = 14). Using the reference approach, the differences in the empiric kinetic parameters within the LDpA groups were evaluated. The reference LDpAs were compared with those derived from only 2, 3, or 4 PET data points and from 1 adapted 2-point approach. Lin's concordance correlation coefficient (rho(c)) and the mean absolute percentage deviation in LDpAs were used to assess agreement between simplified and reference approaches. Results: The effective I-124 half-life, linear activity-concentration rate (alpha), and 24-h activity concentration (CpA) (the latter 2 per administered I-124 activity) differed significantly among the LDpA groups (P < 0.05). LDpAs correlated with 24-h CpAs (r = 0.94, P < 0.001). Using the 4-, 24-, and 96-h measurements, a rho(c) value of greater than or equal to 0.90 was found, and the mean absolute percentage deviation was less than or equal to 16%. Similar statistical values were obtained for the adapted approach, which was based on 24- and 96-h PET data points only. Conclusion: Lesion classification into LDpA groups was feasible using a single PET scan at similar to 24 h. Because of the highly variable kinetics, 1 additional measurement at similar to 96 h was needed to obtain a sufficiently reliable LDpA estimate. The adapted 24-96-h approach appears to be the optimal I-124 protocol and is a reliable simplification of the 5-point protocol.
引用
收藏
页码:1017 / 1023
页数:7
相关论文
共 13 条
[1]  
[Anonymous], 1975, S ABSORBED DOSE UNIT
[2]  
Erdi Yusuf E., 1999, Clin Positron Imaging, V2, P41, DOI 10.1016/S1095-0397(99)00004-7
[3]   Evaluation of dosimetry of radioiodine therapy in benign and malignant thyroid disorders by means of iodine-124 and PET [J].
Eschmann, SM ;
Reischl, G ;
Bilger, K ;
Kupferschläger, J ;
Thelen, MH ;
Dohmen, BM ;
Besenfelder, H ;
Bares, R .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2002, 29 (06) :760-767
[4]  
Freudenberg LS, 2007, EUR J NUCL MED MOL I, V34, pS199
[5]   124I-PET dosimetry in advanced differentiated thyroid cancer:: Therapeutic impact [J].
Freudenberg, L. S. ;
Jentzen, W. ;
Goerges, R. ;
Petrich, T. ;
Marlowe, R. J. ;
Knust, J. ;
Bockisch, A. .
NUKLEARMEDIZIN-NUCLEAR MEDICINE, 2007, 46 (04) :121-128
[6]   Value of 124I-PET/CT in staging of patients with differentiated thyroid cancer [J].
Freudenberg, LS ;
Antoch, G ;
Jentzen, W ;
Pink, R ;
Knust, J ;
Görges, R ;
Müller, SP ;
Bockisch, A ;
Debatin, JF ;
Brandau, W .
EUROPEAN RADIOLOGY, 2004, 14 (11) :2092-2098
[7]  
*IEC, 1998, 616751 IEC 1
[8]  
Jentzen W, 2007, J NUCL MED, V48, P108
[9]   Use of recovery coefficients as a test of system linearity of response in positron emission tomography (PET) [J].
Knoop, BO ;
Geworski, L ;
Hofmann, M ;
Munz, DL ;
Knapp, WH .
PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (08) :1237-1254
[10]   Statistical methods in assessing agreement: Models, issues, and tools [J].
Lin, L ;
Hedayat, AS ;
Sinha, B ;
Yang, M .
JOURNAL OF THE AMERICAN STATISTICAL ASSOCIATION, 2002, 97 (457) :257-270