Effects of xenon on the performance of various respiratory flowmeters

被引:16
作者
Goto, T
Saito, H
Nakata, Y
Uezono, S
Ichinose, F
Uchiyama, M
Morita, S
机构
[1] Teikyo Univ, Ichihara Hosp, Dept Anesthesia, Chiba 2990111, Japan
[2] Nihon Univ, Sch Med, Chiba, Japan
关键词
density; measurement error; respiratory monitoring; thermal capacity; thermal conductivity;
D O I
10.1097/00000542-199902000-00032
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background The anesthetic gas xenon has distinctly different physical properties compared with air, nitrous oxide, or oxygen. This led us to predict that xenon would affect the performance of commercially available flowmeters. Methods: Flow was generated by an anesthesia ventilator connected to a lung simulator via a semiclosed breathing circuit. With the system filled with air or with various concentrations of xenon or nitrous oxide in a balance of oxygen, the tidal volume was measured with two rotating vanes, a Pitot tube, a variable-orifice flowmeter, and two constant-temperature hot-wire flowmeters. Results: Although xenon minimally affected both rotating vane flowmeters, it caused the Pitot tube and the variable-orifice flowmeters to overread in proportion to the square root of the density of the gas mixture used (xenon is 4.6 times more dense than air). In contrast, the hot-wire anemometers underread with xenon; for example, their readings in the presence of 45% and 70% xenon were less than 10% of those displayed when air was used. Nitrous oxide minimally affected all the flowmeters except the variable-orifice device. The Pitot flowmeter was also affected, but only when its gas analyzer port was open to the ambient air so that it no longer corrected its readings for changes in gas composition. In these cases, nitrous oxide produced overreadings in the same manner as did xenon. Conclusion: Among the four types of flowmeters studied, only the rotating-vane type is sufficiently accurate for use during anesthesia with xenon.
引用
收藏
页码:555 / 563
页数:9
相关论文
共 17 条
[1]   OBSERVATIONS ON ANESTHETIC EFFECT OF COMBINATION OF XENON AND HALOTHANE [J].
CULLEN, SC ;
EGER, EI ;
CULLEN, BF ;
GREGORY, P .
ANESTHESIOLOGY, 1969, 31 (04) :305-+
[2]  
GAL TJ, 1990, CLIN MONITORING, P315
[3]   The blood-gas partition coefficient of xenon may be lower than generally accepted [J].
Goto, T ;
Suwa, K ;
Uezono, S ;
Ichinose, F ;
Uchiyama, M ;
Morita, S .
BRITISH JOURNAL OF ANAESTHESIA, 1998, 80 (02) :255-256
[4]   Xenon provides faster emergence from anesthesia than does nitrous oxide sevoflurane or nitrous oxide isoflurane [J].
Goto, T ;
Saito, H ;
Shinkai, M ;
Nakata, Y ;
Ichinose, F ;
Morita, S .
ANESTHESIOLOGY, 1997, 86 (06) :1273-1278
[5]   NEW TRANSDUCER FOR RESPIRATORY MONITORING - DESCRIPTION OF A HOT-WIRE ANEMOMETER AND A TEST PROCEDURE FOR GENERAL USE [J].
KANN, T ;
HALD, A ;
JORGENSEN, FE .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1979, 23 (04) :349-358
[6]   ANESTHESIA AND THE INERT-GASES WITH SPECIAL REFERENCE TO XENON [J].
KENNEDY, RR ;
STOKES, JW ;
DOWNING, P .
ANAESTHESIA AND INTENSIVE CARE, 1992, 20 (01) :66-70
[7]   EVALUATION OF A CONSTANT-TEMPERATURE HOT-WIRE ANEMOMETER FOR RESPIRATORY-GAS-FLOW MEASUREMENTS [J].
LUNDSGAARD, JS ;
GRONLUND, J ;
EINERJENSEN, N .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1979, 17 (02) :211-215
[8]   A NOVEL SENSOR FOR ROUTINE CONTINUOUS SPIROMETRY OF INTUBATED PATIENTS [J].
MERILAINEN, P ;
HANNINEN, H ;
TUOMAALA, L .
JOURNAL OF CLINICAL MONITORING, 1993, 9 (05) :374-380
[9]   Comparison of inhalation inductions with xenon and sevoflurane [J].
Nakata, Y ;
Goto, T ;
Morita, S .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1997, 41 (09) :1157-1161
[10]   ACCURACY OF RESPIROMETER AND VENTIGRATOR [J].
NUNN, JF ;
EZIASHI, TI .
BRITISH JOURNAL OF ANAESTHESIA, 1962, 34 (07) :422-&