Development of a membrane-based electrochemical immunosensor

被引:25
作者
Koh, Guiwan [1 ]
Agarwal, Shuchi [1 ]
Cheow, Pui-Sze [1 ]
Toh, Chee-Seng [1 ]
机构
[1] Natl Univ Singapore, Fac Sci, Dept Chem, Singapore 117543, Singapore
关键词
alumina; immunosensor; glucose oxidase; nanostructure; immunoglobulin;
D O I
10.1016/j.electacta.2007.07.055
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
A membrane-based electrochemical inummosensor sensitive towards proteins is described, based on nanoporous alumina-modified platinum wire electrodes. The sensing mechanism depends on the blocking of pore channels when the protein antigen molecules bind to antibody molecules attached to the channel walls, impeding the diffusion of redox probe, ferrocenemethanol, towards the sensing platinum wire overlaid by the nanoporous alumina film. The antibody and antigen used in this work were anti-glucose oxidase and glucose oxidase, respectively. The immunosensor showed a low limit of detection of 100 ng L-1 antigen concentration and was selective towards glucose oxidase protein in the presence of another protein, glucothione S-transferase. (c) 2007 Elsevier Ltd. All rights reserved.
引用
收藏
页码:803 / 810
页数:8
相关论文
共 19 条
[1]   Biosensor for Dengue virus detection: Sensitive, rapid, and serotype specific [J].
Baeumner, AJ ;
Schlesinger, NA ;
Slutzki, NS ;
Romano, J ;
Lee, EM ;
Montagna, RA .
ANALYTICAL CHEMISTRY, 2002, 74 (06) :1442-1448
[2]  
Bard A. J., 2001, ELECTROCHEMICAL METH, P44
[3]   Comparison of two rapid influenza A/B test kits with reference methods showing high specificity and sensitivity for influenza A infection [J].
Booth, S ;
Baleriola, C ;
Rawlinson, WD .
JOURNAL OF MEDICAL VIROLOGY, 2006, 78 (05) :619-622
[4]   ANODIC OXIDE FILMS ON ALUMINUM [J].
DIGGLE, JW ;
DOWNIE, TC ;
GOULDING, CW .
CHEMICAL REVIEWS, 1969, 69 (03) :365-&
[5]   Characterization of the barrier layer of nanoporous alumina films prepared using two different contact configurations [J].
Koh, Guiwan ;
Agarwal, Shuchi ;
Cheow, Pui-Sze ;
Toh, Chee-Seng .
ELECTROCHIMICA ACTA, 2007, 52 (08) :2815-2821
[6]   Thermotreatment and chemical resistance of porous alumina membrane prepared by anodic oxidation [J].
Lee, CW ;
Kang, HS ;
Chang, YH ;
Hahm, YM .
KOREAN JOURNAL OF CHEMICAL ENGINEERING, 2000, 17 (03) :266-272
[7]   Mediated amperometric immunosensing using single walled carbon nanotube forests [J].
O'Connor, M ;
Kim, SN ;
Killard, AJ ;
Forster, RJ ;
Smyth, MR ;
Papadimitrakopoulos, F ;
Rusling, JF .
ANALYST, 2004, 129 (12) :1176-1180
[8]   Construction of an electrochemical probe for on chip type flow immunoassay [J].
Okochi, M ;
Ohta, H ;
Taguchi, T ;
Ohta, H ;
Matsunaga, T .
ELECTROCHIMICA ACTA, 2005, 51 (05) :952-955
[9]   MORPHOLOGY AND MECHANISM OF FORMATION OF POROUS ANODIC FILMS ON ALUMINIUM [J].
OSULLIVAN, JP ;
WOOD, GC .
PROCEEDINGS OF THE ROYAL SOCIETY OF LONDON SERIES A-MATHEMATICAL AND PHYSICAL SCIENCES, 1970, 317 (1531) :511-+
[10]   Electrochemical enzyme-linked immunoassay in a DNA hybridization sensor [J].
Palecek, E ;
Kizek, R ;
Havran, L ;
Billova, S ;
Fojta, M .
ANALYTICA CHIMICA ACTA, 2002, 469 (01) :73-83