A simple method for measuring the potential resuspension of dust from carpets in the indoor environment

被引:17
作者
Kildeso, J [1 ]
Vinzents, P [1 ]
Schneider, T [1 ]
Kloch, NP [1 ]
机构
[1] Natl Inst Occupat Hlth, DK-2100 Copenhagen, Denmark
关键词
D O I
10.1177/004051759906900303
中图分类号
TB3 [工程材料学]; TS1 [纺织工业、染整工业];
学科分类号
0805 ; 080502 ; 0821 ;
摘要
Carpets have an important influence on the comfort of room occupants in the indoor environment, but dust accumulating in carpets due to insufficient cleaning may have an adverse effect on indoor air quality. An easy-to-use method for evaluating the cleaning quality of carpets has been developed in this study, based on the resuspension of dust from a carpet by a falling weight. The resuspended dust is drawn with the airflow through a sampling pipe, where part of the dust is deposited on a sticking foil due to turbulence in the pipe. The amount of dust on this foil is quantified by a laser-based instrument. The new method is tested in the laboratory and in the field on three different carpet types with different dust loadings. It proves to be highly feasible for quantifying the potential resuspension of dust from different carpet types.
引用
收藏
页码:169 / 175
页数:7
相关论文
共 12 条
[1]  
*ASTM, 1989, F60889 ASTM
[2]   Cleaning for improved indoor air quality: An initial assessment of effectiveness [J].
Franke, DL ;
Cole, EC ;
Leese, KE ;
Foarde, KK ;
Berry, MA .
INDOOR AIR, 1997, 7 (01) :41-54
[3]   Exposure assessment of airborne microorganisms by fluorescence microscopy and image processing [J].
Kildeso, J ;
Nielsen, BH .
ANNALS OF OCCUPATIONAL HYGIENE, 1997, 41 (02) :201-&
[4]   An intervention study of the effect of improved cleaning methods on the concentration and composition of dust [J].
Kildeso, J ;
Tornvig, L ;
Skov, P ;
Schneider, T .
INDOOR AIR-INTERNATIONAL JOURNAL OF INDOOR AIR QUALITY AND CLIMATE, 1998, 8 (01) :12-22
[5]  
KIVISTO T, 1981, STAUB REINHALT LUFT, V41, P357
[6]   APPLICATIONS OF CLOSELY GRADED POWDERS OF FUSED ALUMINA AS TEST DUSTS FOR AEROSOL STUDIES [J].
MARK, D ;
VINCENT, JH ;
GIBSON, H ;
WITHERSPOON, WA .
JOURNAL OF AEROSOL SCIENCE, 1985, 16 (02) :125-131
[7]   Design and calibration of a simple instrument for measuring dust on surfaces in the indoor environment [J].
Schneider, T ;
Petersen, OH ;
Kildeso, J ;
Kloch, NP ;
Lobner, T .
INDOOR AIR-INTERNATIONAL JOURNAL OF INDOOR AIR QUALITY AND CLIMATE, 1996, 6 (03) :204-210
[8]   QUALITY OF CLEANING QUANTIFIED [J].
SCHNEIDER, T ;
LOBNER, T ;
NILSEN, SK ;
PETERSEN, OH .
BUILDING AND ENVIRONMENT, 1994, 29 (03) :363-367
[9]  
SCHNEIDER T, 1992, SIMPLE COMPREHENSIVE, P284
[10]   SICK BUILDING SYNDROME (SBS) IN OFFICE WORKERS AND FACIAL SKIN SYMPTOMS AMONG VDT-WORKERS IN RELATION TO BUILDING AND ROOM CHARACTERISTICS - 2 CASE-REFERENT STUDIES [J].
SUNDELL, J ;
LINDVALL, T ;
STENBERG, B ;
WALL, S .
INDOOR AIR-INTERNATIONAL JOURNAL OF INDOOR AIR QUALITY AND CLIMATE, 1994, 4 (02) :83-94