Trends and progress in the characterization of stationary phases for reversed-phase liquid chromatography

被引:100
作者
Claessens, HA [1 ]
机构
[1] Eindhoven Univ Technol, Instrumental Anal Lab, Dept Chem & Chem Engn, NL-5600 MB Eindhoven, Netherlands
关键词
column testing and selection; testing parameters; chemical stability; column lifespan; batch-to-batch repeatabilities; selectivity; eluent properties;
D O I
10.1016/S0165-9936(01)00098-X
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The state-of-the-art and progress in the characterization of reversed-phase liquid chromatographic (RPLC) columns are discussed. Existing column tests are compared with tests under development. The validity of several test parameters, e.g. hydrophobicity and silanol activity, is also discussed. Solvent and eluent properties are treated with respect to retention and selectivity. Developments to improve the chemical stability of RPLC phases and thus column lifetime are reviewed. It is shown that substantial progress has been made in the manufacturing of RPLC columns, enabling their use over a wide variety of experimental conditions. In addition, general measures to significantly extend their lifespan are discussed. The substantial improvements in batch-to-batch and column-to-column repeatabilities achieved during the last two decades are also reviewed. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:563 / 583
页数:21
相关论文
共 101 条
[1]  
Abraham MH, 1997, J PHYS ORG CHEM, V10, P358, DOI 10.1002/(SICI)1099-1395(199705)10:5<358::AID-POC907>3.0.CO
[2]  
2-N
[3]   Determination of solute lipophilicity, as log P(octanol) and log P(alkane) using poly(styrene-divinylbenzene) and immobilised artificial membrane stationary phases in reversed-phase high-performance liquid chromatography [J].
Abraham, MH ;
Chadha, HS ;
Leitao, ARE ;
Mitchell, RC ;
Lambert, WJ ;
Kaliszan, R ;
Nasal, A ;
Haber, P .
JOURNAL OF CHROMATOGRAPHY A, 1997, 766 (1-2) :35-47
[4]   CHARACTERIZATION OF BONDED PHASES BY SOLID-STATE NMR-SPECTROSCOPY [J].
ALBERT, K ;
BAYER, E .
JOURNAL OF CHROMATOGRAPHY, 1991, 544 (1-2) :345-370
[5]   IMPROVEMENTS IN LIQUID-CHROMATOGRAPHY COLUMN LIFE AND METHOD FLEXIBILITY BY SATURATING THE MOBILE PHASE WITH SILICA [J].
ATWOOD, JG ;
SCHMIDT, GJ ;
SLAVIN, W .
JOURNAL OF CHROMATOGRAPHY, 1979, 171 (APR) :109-115
[6]  
BACZEK T, 2000, J HIGH RES CHROMATOG, V23, P667
[7]   The application of factor analysis to solvatochromic parameters and pHs values for the standardization of potentiometric sensors in mobile phases used in liquid chromatography [J].
Barbosa, J ;
Marqués, I ;
Barrón, D ;
Sanz-Nebot, V .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1999, 18 (08) :543-549
[8]   Characterization of a range of alkyl-bonded silica HPLC stationary phases: Chromatographic behavior of neutral, acidic, and basic test solutes [J].
Barrett, DA ;
Brown, VA ;
Shaw, PN ;
Davies, MC ;
Ritchie, H ;
Ross, P .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1996, 34 (03) :146-156
[9]   Strategies for solvent selection - A literature review [J].
Barwick, VJ .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1997, 16 (06) :293-309
[10]   Characterization of wide-pore reversed-phase columns for biopolymer separations .1. Single-parametric evaluation [J].
Bede, A ;
Rippel, G ;
Szepesy, L ;
Claessens, HA .
JOURNAL OF CHROMATOGRAPHY A, 1996, 728 (1-2) :179-188