Performance assessment of the Medtronic-MiniMed Continuous Glucose Monitoring System and its use for measurement of glycaemic control in Type 1 diabetic subjects

被引:105
作者
Sachedina, N [1 ]
Pickup, JC [1 ]
机构
[1] Guys Hosp, Guys Kings & St Thomas Sch Med, Metab Unit, London SE1 9RT, England
关键词
blood glucose self-monitoring; glucose sensor; glycaemic control; hypoglycaemia; post-prandial hyperglycaemia; Type; 1; diabetes;
D O I
10.1046/j.1464-5491.2003.01037.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims To assess the accuracy, reliability and measurement of glycaemic control associated with the Medtronic-MiniMed Continuous Glucose Monitoring System (CGMS) in comparison with blood glucose self-monitoring (BGSM) in Type 1 diabetic patients. Methods Type 1 diabetic patients (n = 18) underwent glucose monitoring by the CGMS for up to 3 days, when control was also assessed by BGSM performed eight times daily. Results Ninety-five per cent of paired non calibration samples were in the clinically acceptable zones of the Clarke error grid, and 97% in a consensus grid. The median bias was 0.1 mmol/l and relative bias 15%. The failure rate of sensors was 28% of those initially inserted. The CGMS detected significantly more hypoglycaemia and post-prandial hyperglycaemia, but total duration of hyperglycaemia, blood glucose oscillations and day-to-day variability were similarly assessed by CGMS and BGSM. Conclusions The CGMS has acceptable clinical accuracy. Detection by the CGMS of more hypoglycaemia and post-prandial hyperglycaemia than BGSM promises a valuable tool for control assessment and optimization of treatment.
引用
收藏
页码:1012 / 1015
页数:4
相关论文
共 17 条
[1]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[2]   Continuous glucose monitoring used to adjust diabetes therapy improves glycosylated hemoglobin: a pilot study [J].
Bode, BW ;
Gross, TM ;
Thornton, KR ;
Mastrototaro, JJ .
DIABETES RESEARCH AND CLINICAL PRACTICE, 1999, 46 (03) :183-190
[3]   Limitations of conventional methods of self-monitoring of blood glucose - Lessons learned from 3 days of continuous glucose sensing in pediatric patients with type 1 diabetes [J].
Boland, E ;
Monsod, T ;
Delucia, M ;
Brandt, CA ;
Fernando, S ;
Tamborlane, WV .
DIABETES CARE, 2001, 24 (11) :1858-1862
[4]   Continuous subcutaneous glucose monitoring in children with type 1 diabetes [J].
Chase, HP ;
Kim, LM ;
Owen, SL ;
MacKenzie, TA ;
Klingensmith, GJ ;
Murtfeldt, R ;
Garg, SK .
PEDIATRICS, 2001, 107 (02) :222-226
[5]   EVALUATING CLINICAL ACCURACY OF SYSTEMS FOR SELF-MONITORING OF BLOOD-GLUCOSE [J].
CLARKE, WL ;
COX, D ;
GONDERFREDERICK, LA ;
CARTER, W ;
POHL, SL .
DIABETES CARE, 1987, 10 (05) :622-628
[6]   Frequency of blood glucose monitoring in relation to glycaemic control: observational study with diabetes database [J].
Evans, JMM ;
Newton, RW ;
Ruta, DA ;
MacDonald, TM ;
Stevenson, RJ ;
Morris, AD .
BMJ-BRITISH MEDICAL JOURNAL, 1999, 319 (7202) :83-86
[7]   Reservations on the use of error grid analysis for the validation of blood glucose assays [J].
Gough, DA ;
Botvinick, EL .
DIABETES CARE, 1997, 20 (06) :1034-1036
[8]  
Gross T M, 2000, Diabetes Technol Ther, V2, P49, DOI 10.1089/152091500316737
[9]  
GROSS TM, 2000, DIABETES TECHNOL THE, V2, P27
[10]   A pilot study of the continuous glucose monitoring system - Clinical decisions and glycemic control after its use in pediatric type 1 diabetic subjects [J].
Kaufman, FR ;
Gibson, LC ;
Halvorson, M ;
Carpenter, S ;
Fisher, LK ;
Pitukcheewanont, P .
DIABETES CARE, 2001, 24 (12) :2030-2034