Accuracy of retinopathy of prematurity image-based diagnosis by pediatric ophthalmology fellows: Implications for training

被引:40
作者
Myung, Jane S. [3 ]
Chan, Robison Vernon Paul [3 ]
Espiritu, Michael J. [3 ]
Williams, Steven L. [4 ]
Granet, David B. [5 ]
Lee, Thomas C. [6 ]
Weissgold, David J. [7 ,8 ]
Chiang, Michael F. [1 ,2 ]
机构
[1] Oregon Hlth & Sci Univ, Casey Eye Inst, Dept Ophthalmol, Portland, OR 97239 USA
[2] Oregon Hlth & Sci Univ, Dept Med Informat & Clin Epidemiol, Portland, OR 97239 USA
[3] Weill Cornell Med Ctr, Dept Ophthalmol, New York, NY USA
[4] Tufts Univ, Tufts Med Ctr, New England Eye Ctr, Boston, MA 02111 USA
[5] Univ Calif San Diego, Dept Ophthalmol, San Diego, CA 92103 USA
[6] Childrens Hosp Los Angeles, Vis Ctr, Los Angeles, CA 90027 USA
[7] Univ Vermont, Coll Med, Retina Ctr Vermont, Burlington, VT USA
[8] Univ Vermont, Coll Med, Div Ophthalmol, Burlington, VT USA
来源
JOURNAL OF AAPOS | 2011年 / 15卷 / 06期
关键词
SCREENING EXAMINATIONS; PLUS DISEASE; AGREEMENT; CARE; PAIN;
D O I
10.1016/j.jaapos.2011.06.011
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE To measure the accuracy of image-based retinopathy of prematurity (ROP) diagnosis by pediatric ophthalmology fellows. METHODS This was a comparative case series of expert versus nonexpert clinicians in image-based ROP diagnosis. An atlas of 804 retinal images was captured from 248 eyes of 67 premature infants with a wide-angle camera (RetCam-II, Clarity Medical Systems, Pleasanton, CA). Images were uploaded to a study website from which an expert pediatric retinal specialist and five pediatric ophthalmology fellows independently provided a diagnosis (no ROP, mild ROP, type 2 ROP, or treatment-requiring ROP) for each eye. Two different retinal specialists experienced in ROP examination served as additional controls. Primary outcome measures were sensitivity and specificity of image-based ROP diagnosis by fellows compared to a reference standard of image-based interpretation by the expert pediatric retinal specialist. Secondary outcome measure was intraphysician reliability. RESULTS For detection of mild or worse ROP, the mean (range) sensitivity among the five fellows was 0.850 (0.670-0.962) and specificity was 0.919 (0.832-0.964). For detection of type 2 or worse ROP by fellows, mean (range) sensitivity was 0.527 (0.356-0.709) and specificity was 0.938 (0.777-1.000). For detection of treatment-requiring ROP, mean (range) sensitivity was 0.515 (0.267-0.765) and specificity was 0.949 (0.805-1.00). CONCLUSIONS Pediatric ophthalmology fellows in this study demonstrated high diagnostic specificity in image-based ROP diagnosis; however, sensitivity was lower, particularly for clinically significant disease. (J AAPOS 2011;15:573-578)
引用
收藏
页码:573 / 578
页数:6
相关论文
共 26 条
[1]   Screening for retinopathy of prematurity:: Is it painful? [J].
Belda, S ;
Pallás, CR ;
De la Cruz, J ;
Tejada, P .
BIOLOGY OF THE NEONATE, 2004, 86 (03) :195-200
[2]   ACCURACY OF RETINOPATHY OF PREMATURITY DIAGNOSIS BY RETINAL FELLOWS [J].
Chan, R. V. Paul ;
Williams, Steven L. ;
Yonekawa, Yoshihiro ;
Weissgold, David J. ;
Lee, Thomas C. ;
Chiang, Michael F. .
RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2010, 30 (06) :958-965
[3]   Remote image based retinopathy of prematurity diagnosis: a receiver operating characteristic analysis of accuracy [J].
Chiang, M. F. ;
Starren, J. ;
Du, Y. E. ;
Keenan, J. D. ;
Schiff, W. M. ;
Barile, G. R. ;
Li, J. ;
Johnson, R. A. ;
Hess, D. J. ;
Flynn, J. T. .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2006, 90 (10) :1292-1296
[4]   Telemedical retinopathy of prematurity diagnosis - Accuracy, reliability, and image quality [J].
Chiang, Michael F. ;
Wang, Lu ;
Busuioc, Mihai ;
Du, Yunling E. ;
Chan, Patrick ;
Kane, Steven A. ;
Lee, Thomas C. ;
Weissgold, David J. ;
Berrocal, Audina M. ;
Coki, Osode ;
Flynn, John T. ;
Starren, Justin .
ARCHIVES OF OPHTHALMOLOGY, 2007, 125 (11) :1531-1538
[5]   Interexpert agreement of plus disease diagnosis in retinopathy of prematurity [J].
Chiang, Michael F. ;
Jiang, Lei ;
Gelman, Rony ;
Du, Yunling E. ;
Flynn, John T. .
ARCHIVES OF OPHTHALMOLOGY, 2007, 125 (07) :875-880
[6]   A COEFFICIENT OF AGREEMENT FOR NOMINAL SCALES [J].
COHEN, J .
EDUCATIONAL AND PSYCHOLOGICAL MEASUREMENT, 1960, 20 (01) :37-46
[7]   Pain in neonates during screening for retinopathy of prematurity using binocular indirect ophthalmoscopy and wide-field digital retinal imaging: a randomised comparison [J].
Dhaliwal, C. A. ;
Wright, E. ;
McIntosh, N. ;
Dhaliwal, K. ;
Fleck, B. W. .
ARCHIVES OF DISEASE IN CHILDHOOD-FETAL AND NEONATAL EDITION, 2010, 95 (02) :F146-F148
[8]  
Good WV, 2003, ARCH OPHTHALMOL-CHIC, V121, P1684
[9]   Retinopathy of prematurity care: Patterns of care and workforce analysis [J].
Kemper, Alex R. ;
Freedman, Sharon F. ;
Wallace, David K. .
JOURNAL OF AAPOS, 2008, 12 (04) :344-348
[10]   MUST SCREENING EXAMINATIONS FOR RETINOPATHY OF PREMATURITY NECESSARILY BE PAINFUL? [J].
Kirchner, Lieselotte ;
Jeitler, Valerie ;
Pollak, Arnold ;
Muellner-Eidenboeck, Andrea ;
Weinzettel, Robert ;
Kraschl, Raimund ;
Waldhoer, Thomas ;
Wald, Martin .
RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2009, 29 (05) :586-591