Water-saturated three-dimensional balanced steady-state free precession for fast abdominal fat quantification

被引:19
作者
Peng, Q
McColl, RW
Wang, JH
Chia, JM
Weatherall, PT
机构
[1] Univ Texas, SW Med Ctr Dallas, Dept Radiol, Dallas, TX 75390 USA
[2] Philips Med Syst, Cleveland, OH USA
关键词
body composition; fat quantification; visceral adipose tissue; steady-state free precession; rapid imaging;
D O I
10.1002/jmri.20252
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare the performance of a novel water-saturated b-SSFP sequence with that of a conventional TI-weighted turbo spin echo (T1W TSE) sequence for abdominal fat quantification. Materials and Methods: A water-saturated, segmented, three-dimensional balanced steady-state free precession (b-SSFP) sequence and a traditional T1W TSE sequence were both employed on phantom and human studies. For phantom studies, a dual-layered phantom with known internal/external oil volumes was imaged using the two sequences. Images obtained by the two sequences were both processed using a computer-aided semiautomatic program for oil volume quantification. For human studies, six volunteers were scanned axially, centered at L2-L3 levels. Signal-to-noise ratio (SNR)(fat), contrast-to-noise ratio (CNR)(fat-muscle), CNRfat-large (bowel), and CNRfat-small bowel were calculated on hand-drawn regions of interest (ROIs), and averaged over all six slices for each subject. Statistical analyses were then performed to determine the SNR and CNR differences between images obtained by the two techniques. Results: The phantom studies show that water-saturated b-SSFP offers a significantly closer estimation of true oil ;volumes compared with that of T1W TSE (P < 0.0001), as well as a more accurate internal/external volume ratio (P = 0.0001). In human studies, three-dimensional water-saturated b-SSFP images demonstrated higher CNR than that of T1W TSE (P < 0.0005), and very close SNRfat (P = 0.045). Conclusion: The proposed three-dimensional water-saturated b-SSFP sequence can generate high quality fat-only abdominal images with high CNR and SNR in shorter scan duration than the conventional T1W TSE approach. As images generated by this sequence suffer from no flow artifacts, and are less sensitive to bulk, respiratory, and bowel motion, three-dimensional water-saturated b-SSFP is a faster and more robust method for improving abdominal fat quantification using MRI.
引用
收藏
页码:263 / 271
页数:9
相关论文
共 40 条
[1]   Insulin resistance and obesity - The role of fat distribution pattern [J].
Abate, N .
DIABETES CARE, 1996, 19 (03) :292-294
[2]  
ABATE N, 1994, J LIPID RES, V35, P1490
[3]  
Barnard ML, 1996, NMR BIOMED, V9, P156, DOI 10.1002/(SICI)1099-1492(199606)9:4<156::AID-NBM412>3.0.CO
[4]  
2-B
[5]   EVIDENCE FOR AN INCREASED RISK FOR HYPERTENSION WITH CENTRALLY LOCATED BODY-FAT AND THE EFFECT OF RACE AND SEX ON THIS RISK [J].
BLAIR, D ;
HABICHT, JP ;
SIMS, EAH ;
SYLWESTER, D ;
ABRAHAM, S .
AMERICAN JOURNAL OF EPIDEMIOLOGY, 1984, 119 (04) :526-540
[6]   MR quantification of muscle fatty replacement in McArdle's disease [J].
deKerviler, E ;
LeroyWillig, A ;
Duboc, D ;
Eymard, B ;
Syrota, A .
MAGNETIC RESONANCE IMAGING, 1996, 14 (10) :1137-1141
[7]   Breath-hold three-dimensional true-FISP imaging of coronary arteries using asymmetric sampling [J].
Deshpande, VS ;
Shea, SM ;
Chung, YC ;
McCarthy, RM ;
Finn, JP ;
Li, DB .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2002, 15 (04) :473-478
[8]   3D magnetization-prepared true-FISP: A new technique for imaging coronary arteries [J].
Deshpande, VS ;
Shea, SM ;
Laub, G ;
Simonetti, OP ;
Finn, JP ;
Li, DB .
MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (03) :494-502
[9]   SIMPLE PROTON SPECTROSCOPIC IMAGING [J].
DIXON, WT .
RADIOLOGY, 1984, 153 (01) :189-194
[10]   Using a phantom to compare MR techniques for determining the ratio of intraabdominal to subcutaneous adipose tissue. [J].
Donnelly, LF ;
O'Brien, KJ ;
Dardzinski, BJ ;
Poe, SA ;
Bean, JA ;
Holland, SK ;
Daniels, SR .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2003, 180 (04) :993-998