Water-saturated three-dimensional balanced steady-state free precession for fast abdominal fat quantification

被引:19
作者
Peng, Q
McColl, RW
Wang, JH
Chia, JM
Weatherall, PT
机构
[1] Univ Texas, SW Med Ctr Dallas, Dept Radiol, Dallas, TX 75390 USA
[2] Philips Med Syst, Cleveland, OH USA
关键词
body composition; fat quantification; visceral adipose tissue; steady-state free precession; rapid imaging;
D O I
10.1002/jmri.20252
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare the performance of a novel water-saturated b-SSFP sequence with that of a conventional TI-weighted turbo spin echo (T1W TSE) sequence for abdominal fat quantification. Materials and Methods: A water-saturated, segmented, three-dimensional balanced steady-state free precession (b-SSFP) sequence and a traditional T1W TSE sequence were both employed on phantom and human studies. For phantom studies, a dual-layered phantom with known internal/external oil volumes was imaged using the two sequences. Images obtained by the two sequences were both processed using a computer-aided semiautomatic program for oil volume quantification. For human studies, six volunteers were scanned axially, centered at L2-L3 levels. Signal-to-noise ratio (SNR)(fat), contrast-to-noise ratio (CNR)(fat-muscle), CNRfat-large (bowel), and CNRfat-small bowel were calculated on hand-drawn regions of interest (ROIs), and averaged over all six slices for each subject. Statistical analyses were then performed to determine the SNR and CNR differences between images obtained by the two techniques. Results: The phantom studies show that water-saturated b-SSFP offers a significantly closer estimation of true oil ;volumes compared with that of T1W TSE (P < 0.0001), as well as a more accurate internal/external volume ratio (P = 0.0001). In human studies, three-dimensional water-saturated b-SSFP images demonstrated higher CNR than that of T1W TSE (P < 0.0005), and very close SNRfat (P = 0.045). Conclusion: The proposed three-dimensional water-saturated b-SSFP sequence can generate high quality fat-only abdominal images with high CNR and SNR in shorter scan duration than the conventional T1W TSE approach. As images generated by this sequence suffer from no flow artifacts, and are less sensitive to bulk, respiratory, and bowel motion, three-dimensional water-saturated b-SSFP is a faster and more robust method for improving abdominal fat quantification using MRI.
引用
收藏
页码:263 / 271
页数:9
相关论文
共 40 条
[11]   Fast proton spectroscopic imaging using steady-state free precession methods [J].
Dreher, W ;
Geppert, C ;
Althaus, M ;
Leibfritz, D .
MAGNETIC RESONANCE IN MEDICINE, 2003, 50 (03) :453-460
[12]   MR angiography using steady-state free precession [J].
Foo, TKF ;
Ho, VB ;
Marcos, HB ;
Hood, MN ;
Choyke, PL .
MAGNETIC RESONANCE IN MEDICINE, 2002, 48 (04) :699-706
[13]  
FOSTER M A, 1984, Magnetic Resonance Imaging, V2, P187, DOI 10.1016/0730-725X(84)90004-3
[14]   VALIDATION OF THE INVIVO MEASUREMENT OF ADIPOSE-TISSUE BY MAGNETIC-RESONANCE-IMAGING OF LEAN AND OBESE PIGS [J].
FOWLER, PA ;
FULLER, MF ;
GLASBEY, CA ;
CAMERON, GG ;
FOSTER, MA .
AMERICAN JOURNAL OF CLINICAL NUTRITION, 1992, 56 (01) :7-13
[15]   OVERALL BODY-FAT AND REGIONAL FAT DISTRIBUTION IN YOUNG-WOMEN - QUANTIFICATION WITH MR IMAGING [J].
GERARD, EL ;
SNOW, RC ;
KENNEDY, DN ;
FRISCH, RE ;
GUIMARAES, AR ;
BARBIERI, RL ;
SORENSEN, AG ;
EGGLIN, TK ;
ROSEN, BR .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1991, 157 (01) :99-104
[16]   MULTIPOINT DIXON TECHNIQUE FOR WATER AND FAT PROTON AND SUSCEPTIBILITY IMAGING [J].
GLOVER, GH .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1991, 1 (05) :521-530
[17]   3-POINT DIXON TECHNIQUE FOR TRUE WATER FAT DECOMPOSITION WITH BO INHOMOGENEITY CORRECTION [J].
GLOVER, GH ;
SCHNEIDER, E .
MAGNETIC RESONANCE IN MEDICINE, 1991, 18 (02) :371-383
[18]   Fat-suppressed steady-state free precession imaging using phase detection [J].
Hargreaves, BA ;
Vasanawala, SS ;
Nayak, KS ;
Hu, BS ;
Nishimura, DG .
MAGNETIC RESONANCE IN MEDICINE, 2003, 50 (01) :210-213
[19]   Characterization and reduction of the transient response in steady-state MR imaging [J].
Hargreaves, BA ;
Vasanawala, SS ;
Pauly, JM ;
Nishimura, DG .
MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (01) :149-158
[20]   Fat and water separation in balanced steady-state free precession using the Dixon method [J].
Huang, TY ;
Chung, HW ;
Wang, FN ;
Ko, CW ;
Chen, CY .
MAGNETIC RESONANCE IN MEDICINE, 2004, 51 (02) :243-247