Micropillar array chip for integrated white blood cell isolation and PCR

被引:55
作者
Panaro, NJ
Lou, XJ
Fortina, P
Kricka, LJ
Wilding, P
机构
[1] Hosp Univ Penn, Dept Pathol & Lab Med, Philadelphia, PA 19104 USA
[2] Univ Penn, Dept Pathol & Lab Med, Philadelphia, PA 19104 USA
[3] Thomas Jefferson Univ, Jefferson Med Coll, Dept Med, Ctr Translat Med, Philadelphia, PA 19107 USA
来源
BIOMOLECULAR ENGINEERING | 2005年 / 21卷 / 06期
关键词
micropillars; blood cell isolation; polymerase chain reaction; microfluidic modeling;
D O I
10.1016/j.bioeng.2004.11.001
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We report the fabrication of silicon chips containing a row of 667 pillars, 10 by 20 mu m in cross-section, etched to a depth of 80 mu m with adjacent pillars being separated by 3.5 mu m. The chips were used to separate white blood cells from whole blood in less than 2 min and for subsequent PCR of a genomic target (eNOS). Chip fluid dynamics were validated experimentally using CoventorWare (TM) microfluidic simulation software. The amplicon concentrations were determined using microchip capillary electrophoresis and were > 40% of that observed in conventional PCR tubes for chips with and without pillars. Reproducible on-chip PCR was achieved using white blood cell preparations isolated from whole human blood pumped through the chip. (c) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:157 / 162
页数:6
相关论文
共 24 条
[1]   Purification and characterization of PCR-inhibitory components in blood cells [J].
Abu al-Soud, W ;
Rådström, P .
JOURNAL OF CLINICAL MICROBIOLOGY, 2001, 39 (02) :485-493
[2]   A miniature integrated device for automated multistep genetic assays [J].
Anderson, Rolfe C. ;
Su, Xing ;
Bogdan, Gregory J. ;
Fenton, Jeffery .
NUCLEIC ACIDS RESEARCH, 2000, 28 (12)
[3]  
[Anonymous], 2001, BIOCHIP TECHNOLOGY
[4]  
BEUTLER E, 1990, BIOTECHNIQUES, V9, P166
[5]   Microfabricated structures for integrated DNA analysis [J].
Burns, MA ;
Mastrangelo, CH ;
Sammarco, TS ;
Man, FP ;
Webster, JR ;
Johnson, BN ;
Foerster, B ;
Jones, D ;
Fields, Y ;
Kaiser, AR ;
Burke, DT .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1996, 93 (11) :5556-5561
[6]  
CAO T, 2002, AM BIOTECHNOL LAB
[7]   Self-sorting of white blood cells in a lattice [J].
Carlson, RH ;
Gabel, CV ;
Chan, SS ;
Austin, RH ;
Brody, JP ;
Winkelman, JW .
PHYSICAL REVIEW LETTERS, 1997, 79 (11) :2149-2152
[8]   Chip PCR .2. Investigation of different PCR amplification systems in microfabricated silicon-glass chips [J].
Cheng, J ;
Shoffner, MA ;
Hvichia, GE ;
Kricka, LJ ;
Wilding, P .
NUCLEIC ACIDS RESEARCH, 1996, 24 (02) :380-385
[9]   Analysis of ligase chain reaction products amplified in a silicon-glass chip using capillary electrophoresis [J].
Cheng, J ;
Shoffner, MA ;
Mitchelson, KR ;
Kricka, LJ ;
Wilding, P .
JOURNAL OF CHROMATOGRAPHY A, 1996, 732 (01) :151-158
[10]   A microfabricated fluorescence-activated cell sorter [J].
Fu, AY ;
Spence, C ;
Scherer, A ;
Arnold, FH ;
Quake, SR .
NATURE BIOTECHNOLOGY, 1999, 17 (11) :1109-1111