Leakage flow measurements in a bio-centrifugal ventricular assist device model

被引:11
作者
Chua, LP [1 ]
Ong, KS [1 ]
Yu, CMS [1 ]
Zhou, TM [1 ]
机构
[1] Nanyang Technol Univ, Sch Mech & Prod Engn, Singapore 639798, Singapore
关键词
ventricular assist device; bio-centrifugal pump; leakage flow; constant temperature anemometer;
D O I
10.1046/j.1525-1594.2003.00033.x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The magnetically suspended impeller centrifugal blood pump (MSCBP) has shown its superiority as compared to other artificial hearts. However, it is still plagued by hemolysis and thrombus formation in the clearance gap between the impeller shroud surface and the pump casing. In an early study, a 5 : 1 scaled up model was built in order to measure the radial and tangential velocities at the gap under the operating condition of a flow coefficient (Phi) of 0.04 using a hot wire anemometer. In this study, velocity profiles were obtained at two critical flow coefficients, Phi =0.078 (fully opened condition) and 0 (fully closed condition), to further the understanding of the flow field in the pump. Similar to the operating condition, the vector plot of the resultant velocity under these two flow coefficients showed that there were no vortices in the gap and a washout mechanism presented at the region around the starting of the splitter plate of the double volute. It was found that the washout mechanism was more obvious in the fully closed condition than in the fully opened condition. This has suggested that with real life operation, the pump could occasionally be operated at a relatively lower flow rate (e.g., under the resting condition of the patient) to obtain a good washout in the gap and thus reduce thrombus formation at the pump casing.
引用
收藏
页码:942 / 959
页数:18
相关论文
共 14 条
[1]   RECENT STUDIES OF THE CENTRIFUGAL BLOOD PUMP WITH A MAGNETICALLY SUSPENDED IMPELLER [J].
AKAMATSU, T ;
TSUKIYA, T ;
NISHIMURA, K ;
PARK, CH ;
NAKAZEKI, T .
ARTIFICIAL ORGANS, 1995, 19 (07) :631-634
[2]  
AKAMATSU T, 1997, P ASME FLUIDS ENG DI
[3]  
AKAMATSU T, 1994, P 3 JSME KSME FLUIDS, P305
[4]  
AKAMATSU T, 1992, ARTIF ORGANS, V16, P290
[5]  
BAUERMEISTER U, 1982, ASAIO ABSTR, V11, P1
[6]   CALIBRATION OF HOT FILMS FOR SKIN FRICTION MEASUREMENT [J].
BROWN, GL ;
DAVEY, RF .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1971, 42 (11) :1729-&
[7]   Preliminary measurements of an enlarged blood pump model [J].
Chua, LP ;
Akamatsu, T ;
Chan, WK .
INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 1998, 25 (08) :1055-1064
[8]   Measurements of gap pressure and wall shear stress of a blood pump model [J].
Chua, LP ;
Akamatsu, T .
MEDICAL ENGINEERING & PHYSICS, 2000, 22 (03) :175-188
[9]   Gap velocity measurements of a blood pump model [J].
Chua, LP ;
Ong, KS ;
Yu, CMS ;
Chan, WK ;
Wong, YW .
ARTIFICIAL ORGANS, 2002, 26 (08) :682-694
[10]  
GEREMIA JO, 1972, DISA INFORM, V13, P5