PEEK biomaterials in trauma, orthopedic, and spinal implants

被引:2146
作者
Kurtz, Steven M.
Devine, John N.
机构
[1] Exponent Inc, Philadelphia, PA 19104 USA
[2] Drexel Univ, Sch Biomed Engn Sci & Hlth Syst, Philadelphia, PA 19104 USA
关键词
PEEK; polyetheretherketone; composites; hip resurfacing; spine; fracture fixation;
D O I
10.1016/j.biomaterials.2007.07.013
中图分类号
R318 [生物医学工程];
学科分类号
0831 [生物医学工程];
摘要
Since the 1980s, polyaryletherketones (PAEKs) have been increasingly employed as biomaterials for trauma, orthopedic, and spinal implants. We have synthesized the extensive polymer science literature as it relates to structure, mechanical properties, and chemical resistance of PAEK biomaterials. With this foundation, one can more readily appreciate why this family of polymers will be inherently strong, inert, and biocompatible. Due to its relative inertness, PEEK biotnaterials are an attractive platform upon which to develop novel bioactive materials, and some steps have already been taken in that direction, with the blending of HA and TCP into sintered PEEK. However, to date, blended HA-PEEK composites have involved a trade-off in mechanical properties in exchange for their increased bioactivity. PEEK has had the greatest clinical impact in the field of spine implant design, and PEEK is now broadly accepted as a radiolucent alternative to metallic biomaterials in the spine community. For mature fields, such as total joint replacements and fracture fixation implants, radiolucency is an attractive but not necessarily critical material feature. (c) 2007 Elsevier Ltd. All rights reserved.
引用
收藏
页码:4845 / 4869
页数:25
相关论文
共 200 条
[1]
Mechanical properties of injection molded hydroxyapatite-polyetheretherketone biocomposites [J].
Abu Bakar, MS ;
Cheang, P ;
Khor, KA .
COMPOSITES SCIENCE AND TECHNOLOGY, 2003, 63 (3-4) :421-425
[2]
Tensile properties, tension-tension fatigue and biological response of polyetheretherketone-hydroxyapatite composites for load-bearing orthopedic implants [J].
Abu Bakar, MS ;
Cheng, MHW ;
Tang, SM ;
Yu, SC ;
Liao, K ;
Tan, CT ;
Khor, KA ;
Cheang, P .
BIOMATERIALS, 2003, 24 (13) :2245-2250
[3]
Tensile properties and microstructural analysis of spheroidized hydroxyapatite-poly (etheretherketone) biocomposites [J].
Abu Bakar, MS ;
Cheang, P ;
Khor, KA .
MATERIALS SCIENCE AND ENGINEERING A-STRUCTURAL MATERIALS PROPERTIES MICROSTRUCTURE AND PROCESSING, 2003, 345 (1-2) :55-63
[4]
Akay M, 1995, Proc Inst Mech Eng H, V209, P93, DOI 10.1243/PIME_PROC_1995_209_325_02
[5]
Akay M, 1996, J BIOMED MATER RES, V31, P167
[6]
Clinical and histologic results related to a low-modulus composite total hip replacement stem [J].
Akhavan, Sam ;
Matthiesen, Mary M. ;
Schulte, Leah ;
Penoyar, Tom ;
Kraay, Matthew J. ;
Rimnac, Clare M. ;
Goldberg, Victor M. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2006, 88A (06) :1308-1314
[7]
Early failure of a carbon-fiber composite femoral component [J].
Allcock, S ;
Ali, MA .
JOURNAL OF ARTHROPLASTY, 1997, 12 (03) :356-358
[8]
ANDREW TA, 1986, CLIN ORTHOP RELAT R, P127
[9]
[Anonymous], 1988, Encyclopedia of Polymer Science and Engineering
[10]
[Anonymous], 1985, Engineering Thermoplastics: Properties and Applications