Noninvasive and minimally-invasive optical monitoring technologies

被引:53
作者
Coté, GL [1 ]
机构
[1] Texas A&M Univ, Biomed Engn Program, College Stn, TX 77843 USA
关键词
polarimetry; spectroscopy; fluorescence; micronutrients; glucose;
D O I
10.1093/jn/131.5.1596S
中图分类号
R15 [营养卫生、食品卫生]; TS201 [基础科学];
学科分类号
100403 ;
摘要
With recent advancements in micro-fabrication and nano-fabrication techniques as well as advancements in the photonics industry, there is now the potential to develop less invasive portable sensors for monitoring micronutrients and other substances used to assess overall health. There have been many technology innovations in the central laboratory for these substances for overall health status but the primary motivation for the research and development of a portable field instrument has come from a diabetic patient and market-driven desire to minimally invasively or noninvasively monitor glucose concentrations in vivo. Such a sensor system has the potential to significantly improve the quality of life for the estimated 16 million diabetics in this country by making routine glucose measurements less painful and more convenient. In addition, there is a critical need for the development of less invasive portable technologies to assess micronutrient status (iron, vitamin A, iodine and folate), environmental hazards (lead) and for other disease-related substances, such as billirubin for infant jaundice. Currently, over 100 small companies and universities are working to develop improved monitoring devices, primarily for glucose, and optical methods are a big part of these efforts. in this article many of these potentially less invasive and portable optical sensing technologies, which are currently under investigation, will be reviewed including optical absorption spectroscopy, polarimetry, Raman spectroscopy and fluorescence.
引用
收藏
页码:1596S / 1604S
页数:9
相关论文
共 107 条
[1]  
*AN CORP, 2000, GLUC SENS
[2]  
[Anonymous], 1991, Lancet, V338, P131, DOI 10.1016/0140-6736(91)90133-A
[3]  
[Anonymous], 1989, MULTIVARIATE CALIBRA
[4]  
[Anonymous], 1996, Vitamin A deficiency
[5]   DETERMINATION OF PHYSIOLOGICAL LEVELS OF GLUCOSE IN AN AQUEOUS MATRIX WITH DIGITALLY FILTERED FOURIER-TRANSFORM NEAR-INFRARED SPECTRA [J].
ARNOLD, MA ;
SMALL, GW .
ANALYTICAL CHEMISTRY, 1990, 62 (14) :1457-1464
[6]   Competitive-binding assay method based on fluorescence quenching of ligands held in close proximity by a multivalent receptor [J].
Ballerstadt, R ;
Schultz, JS .
ANALYTICA CHIMICA ACTA, 1997, 345 (1-3) :203-212
[7]   Feasibility of measuring blood glucose concentration by near-infrared Raman spectroscopy [J].
Berger, AJ ;
Itzkan, I ;
Feld, MS .
SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 1997, 53 (02) :287-292
[8]  
Botto LD, 1996, PEDIATRICS, V98, P911
[9]   A QUANTITATIVE ASSESSMENT OF PLASMA HOMOCYSTEINE AS A RISK FACTOR FOR VASCULAR-DISEASE - PROBABLE BENEFITS OF INCREASING FOLIC-ACID INTAKES [J].
BOUSHEY, CJ ;
BERESFORD, SAA ;
OMENN, GS ;
MOTULSKY, AG .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1995, 274 (13) :1049-1057
[10]  
Burmeister JJ, 1999, CLIN CHEM, V45, P1621