Noninvasive and minimally-invasive optical monitoring technologies

被引:53
作者
Coté, GL [1 ]
机构
[1] Texas A&M Univ, Biomed Engn Program, College Stn, TX 77843 USA
关键词
polarimetry; spectroscopy; fluorescence; micronutrients; glucose;
D O I
10.1093/jn/131.5.1596S
中图分类号
R15 [营养卫生、食品卫生]; TS201 [基础科学];
学科分类号
100403 ;
摘要
With recent advancements in micro-fabrication and nano-fabrication techniques as well as advancements in the photonics industry, there is now the potential to develop less invasive portable sensors for monitoring micronutrients and other substances used to assess overall health. There have been many technology innovations in the central laboratory for these substances for overall health status but the primary motivation for the research and development of a portable field instrument has come from a diabetic patient and market-driven desire to minimally invasively or noninvasively monitor glucose concentrations in vivo. Such a sensor system has the potential to significantly improve the quality of life for the estimated 16 million diabetics in this country by making routine glucose measurements less painful and more convenient. In addition, there is a critical need for the development of less invasive portable technologies to assess micronutrient status (iron, vitamin A, iodine and folate), environmental hazards (lead) and for other disease-related substances, such as billirubin for infant jaundice. Currently, over 100 small companies and universities are working to develop improved monitoring devices, primarily for glucose, and optical methods are a big part of these efforts. in this article many of these potentially less invasive and portable optical sensing technologies, which are currently under investigation, will be reviewed including optical absorption spectroscopy, polarimetry, Raman spectroscopy and fluorescence.
引用
收藏
页码:1596S / 1604S
页数:9
相关论文
共 107 条
[41]   MULTIVARIATE DETERMINATION OF GLUCOSE IN WHOLE-BLOOD BY ATTENUATED TOTAL REFLECTION INFRARED-SPECTROSCOPY [J].
HEISE, HM ;
MARBACH, R ;
JANATSCH, G ;
KRUSEJARRES, JD .
ANALYTICAL CHEMISTRY, 1989, 61 (18) :2009-2015
[42]  
Heise HM, 1998, JOURNAL OF NEAR INFRARED SPECTROSCOPY, VOL 6 1998, P349
[43]   MULTISPECTRAL POLARIMETRIC GLUCOSE DETECTION USING A SINGLE POCKELS CELL [J].
KING, TW ;
COTE, GL ;
MCNICHOLS, R ;
GOETZ, MJ .
OPTICAL ENGINEERING, 1994, 33 (08) :2746-2753
[44]  
Klonoff David C., 1998, Clinical Diabetes, V16, P43
[45]   INFLUENCE OF GLUCOSE-CONCENTRATION ON LIGHT-SCATTERING IN TISSUE-SIMULATING PHANTOMS [J].
KOHL, M ;
COPE, M ;
ESSENPREIS, M ;
BOCKER, D .
OPTICS LETTERS, 1994, 19 (24) :2170-2172
[46]   OPTICAL SENSING OF GLUCOSE USING PHASE-MODULATION FLUOROMETRY [J].
LAKOWICZ, JR ;
MALIWAL, B .
ANALYTICA CHIMICA ACTA, 1993, 271 (01) :155-164
[47]  
Lambert J, 1998, IEEE LEOS NEWSLETTER, V12, P19
[48]   APPLICATION FOR NEAR-INFRARED SPECTROSCOPY FOR PREDICTING THE SUGAR CONTENT OF FRUIT JUICES [J].
LANZA, E ;
LI, BW .
JOURNAL OF FOOD SCIENCE, 1984, 49 (04) :995-998
[49]   PERICONCEPTIONAL MULTIVITAMIN USE IN RELATION TO THE RISK OF CONGENITAL URINARY-TRACT ANOMALIES [J].
LI, DK ;
DALING, JR ;
MUELLER, BA ;
HICKOK, DE ;
FANTEL, AG ;
WEISS, NS .
EPIDEMIOLOGY, 1995, 6 (03) :212-218
[50]  
Long D.A., 1977, Raman spectroscopy, P1