Carbon fiber nanoelectrodes modified by single-walled carbon nanotubes

被引:138
作者
Chen, RS [1 ]
Huang, WH [1 ]
Tong, H [1 ]
Wang, ZL [1 ]
Cheng, JK [1 ]
机构
[1] Wuhan Univ, Dept Chem, Wuhan 430072, Peoples R China
关键词
D O I
10.1021/ac0340556
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Microelectrode voltammetry has been considered to be a powerful technique for single biological cell analysis and brain research. In this paper, we have developed a simple method to get highly sensitive carbon fiber nanoelectrodes (CFNE) modified by single-walled carbon nanotubes (SWNTs) on the basis of our previous work. The electrochemical behavior of SWNTs/CFNE was characterized by potassium ferricyanide, dopamine (DA), epinephrine (E), and norepinephrine (NE) using cyclic voltammetry (CV). Compared with CFNE, SWNTs/CFNE has a much larger available internal surface area per external geometric area, which is supported by SEM images. The modified electrodes show very high sensitivity and favorable electrochemical behavior toward these neurotransmitters. The peak current increases linearly with the concentration of DA, E, and NE in the range of 1.0 x 10(-7)-1.0 x 10(-4), 3.0 x 10(-7)-1.0 x 10(-4), and 5.0 x 10(-7)- 1.0 x 10(-4) M, respectively. The CV detection limit (S/N = 3) of DA, E, and NE is 7.7 x 10(-9), 3.8 x 10(-8), and 4.2 x 10(-8) M, respectively. The modified electrode exhibited almost the same electrochemical behavior after 15 days, indicating that SWNTs/CFNE is pretty stable and has good reproducibility.
引用
收藏
页码:6341 / 6345
页数:5
相关论文
共 41 条
[1]   ANALYTICAL APPLICATIONS OF CYLINDRICAL CARBON-FIBER MICROELECTRODES - SIMULTANEOUS VOLTAMMETRIC DETERMINATION OF PHENOLIC ANTIOXIDANTS IN FOOD [J].
AGUI, ML ;
REVIEJO, AJ ;
YANEZSEDENO, P ;
PINGARRON, JM .
ANALYTICAL CHEMISTRY, 1995, 67 (13) :2195-2200
[2]   Nanotubes from carbon [J].
Ajayan, PM .
CHEMICAL REVIEWS, 1999, 99 (07) :1787-1799
[3]   Detection of amino acids at conducting electroactive polymer modified electrodes using flow injection analysis .2. Use of microelectrodes [J].
Akhtar, P ;
Too, CO ;
Wallace, GG .
ANALYTICA CHIMICA ACTA, 1997, 339 (03) :211-223
[4]   A chip-based electrophoresis system with electrochemical detection and hydrodynamic injection [J].
Backofen, U ;
Matysik, FM ;
Lunte, CE .
ANALYTICAL CHEMISTRY, 2002, 74 (16) :4054-4059
[5]   Fully integrated on-chip electrochemical detection for capillary electrophoresis in a microfabricated device [J].
Baldwin, RP ;
Roussel, TJ ;
Crain, MM ;
Bathlagunda, V ;
Jackson, DJ ;
Gullapalli, J ;
Conklin, JA ;
Pai, R ;
Naber, JF ;
Walsh, KM ;
Keynton, RS .
ANALYTICAL CHEMISTRY, 2002, 74 (15) :3690-3697
[6]   Carbon nanotubes - the route toward applications [J].
Baughman, RH ;
Zakhidov, AA ;
de Heer, WA .
SCIENCE, 2002, 297 (5582) :787-792
[7]   COBALT-CATALYZED GROWTH OF CARBON NANOTUBES WITH SINGLE-ATOMIC-LAYERWALLS [J].
BETHUNE, DS ;
KIANG, CH ;
DEVRIES, MS ;
GORMAN, G ;
SAVOY, R ;
VAZQUEZ, J ;
BEYERS, R .
NATURE, 1993, 363 (6430) :605-607
[8]   Microelectrodes for the measurement of catecholamines in biological systems [J].
Cahill, PS ;
Walker, QD ;
Finnegan, JM ;
Mickelson, GE ;
Travis, ER ;
Wightman, RM .
ANALYTICAL CHEMISTRY, 1996, 68 (18) :3180-3186
[9]   PEROXIDASE-MODIFIED CARBON-FIBER MICROELECTRODES IN FLOW-THROUGH DETECTION OF HYDROGEN-PEROXIDE AND ORGANIC PEROXIDES [J].
CSOREGI, E ;
GORTON, L ;
MARKOVARGA, G ;
TUDOS, AJ ;
KOK, WT .
ANALYTICAL CHEMISTRY, 1994, 66 (21) :3604-3610
[10]   Protein electrochemistry at carbon nanotube electrodes [J].
Davis, JJ ;
Coles, RJ ;
Hill, HAO .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1997, 440 (1-2) :279-282