Differential response of delayed healing and persistent inflammation at sites of overlapping sirolimus- or paclitaxel-eluting stents

被引:444
作者
Finn, AV
Kolodgie, FD
Harnek, J
Guerrero, LJ
Acampado, E
Tefera, K
Skorija, K
Weber, DK
Gold, HK
Virmani, R
机构
[1] CVPath, Int Registry Pathol, Gaithersburg, MD 20878 USA
[2] Massachusetts Gen Hosp, Cardiac Unit, Dept Internal Med, Boston, MA 02114 USA
[3] Univ Lund Hosp, Heart Lung Div, S-22185 Lund, Sweden
关键词
drugs; pathology; restenosis; stents;
D O I
10.1161/CIRCULATIONAHA.104.508937
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background - Although effective coverage of challenging coronary lesions has warranted the use of overlapping drug-eluting stents, the histopathological response to stent overlap is unknown. Methods and Results - The arterial reaction to overlapping Cypher or Taxus drug-eluting stents was examined in rabbits with bare metal stents, BxVelocity or Express, serving as controls. Single iliac artery balloon injury was followed by placement of 2 overlapping 3.0-mm-diameter drug-eluting stents or bare metal stents in 60 animals ( mean length of overlap, 9.8 +/- 3.6 mm). Stented arteries were harvested at 28 and 90 days for histology. Overlapped segments exhibited delayed healing compared with proximal and distal nonoverlapping sites at 28 days. Overlapped segments in Taxus stents induced significantly more luminal heterophils/eosinophils and fibrin deposition than Cypher; peristrut giant cell infiltration, however, was more frequent in the latter. Overlapping bare metal stents also showed mild delayed healing compared with nonoverlapped segments, but not to the same extent as drug-eluting stents. Although neointimal thickness within the overlap was similar in 28- and 90-day Cypher stents, there was a significant increase with Taxus (P = 0.03). Conclusions - Compared with bare metal stents, drug-eluting stents further delay arterial healing and promote inflammation at sites of overlap. Taxus stents induced greater fibrin deposition, medial cell loss, heterophils/eosinophils, and late neointimal hyperplasia. Patients receiving overlapping drug-eluting stents need more frequent follow-up than patients with nonoverlapping stents.
引用
收藏
页码:270 / 278
页数:9
相关论文
共 27 条
  • [1] Edge restenosis after implantation of high activity 32P radioactive β-emitting stents
    Albiero, R
    Nishida, T
    Adamian, M
    Amato, A
    Vaghetti, M
    Corvaja, N
    Di Mario, C
    Colombo, A
    [J]. CIRCULATION, 2000, 101 (21) : 2454 - 2457
  • [2] Pressure rinsing of coronary stents immediately before implantation reduces inflammation and neointimal hyperplasia
    Bayes-Genis, A
    Camrud, AR
    Jorgenson, M
    Donovan, J
    Shogren, KL
    Holmes, DR
    Schwartz, RS
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 38 (02) : 562 - 568
  • [3] Long-term effects of polymer-based, slow-release, sirolimus-eluting stents in a porcine coronary model
    Carter, AJ
    Aggarwal, M
    Kopia, GA
    Tio, F
    Tsao, PS
    Kolata, R
    Yeung, AC
    Llanos, G
    Dooley, L
    Falotico, R
    [J]. CARDIOVASCULAR RESEARCH, 2004, 63 (04) : 617 - 624
  • [4] Preliminary observations regarding angiographic pattern of restenosis after rapamycin-eluting stent implantation
    Colombo, A
    Orlic, D
    Stankovic, G
    Corvaja, N
    Spanos, V
    Montorfano, M
    Liistro, F
    Carlino, M
    Airoldi, F
    Chieffo, A
    Di Mario, C
    [J]. CIRCULATION, 2003, 107 (17) : 2178 - 2180
  • [5] DAWKINS K, 2004, MAJOR TAXUS 6 RESULT
  • [6] Very long sirolimus-eluting stent implantation for de novo coronary lesions
    Degertekin, M
    Arampatzis, CA
    Lemos, PA
    Saia, F
    Hoye, A
    Daemen, J
    Tanabe, K
    Lee, CH
    Hofma, SJ
    Sianos, G
    McFadden, E
    van der Giessen, W
    Smits, PC
    De Feyter, PJ
    van Domburg, RT
    Serruys, PW
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2004, 93 (07) : 826 - 829
  • [7] Neointimal thickening after stent delivery of paclitaxel: Change in composition and arrest of growth over six months
    Drachman, DE
    Edelman, ER
    Seifert, P
    Groothuis, AR
    Bornstein, DA
    Kamath, KR
    Palasis, M
    Yang, DC
    Nott, SH
    Rogers, C
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 36 (07) : 2325 - 2332
  • [8] Neointimal responses 3 months after 32P β-emitting stent placement
    Farb, A
    Tang, AL
    Shroff, S
    Sweet, W
    Virmani, R
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2000, 48 (03): : 889 - 898
  • [9] Pathological analysis of local delivery of paclitaxel via a polymer-coated stent
    Farb, A
    Heller, PF
    Shroff, S
    Cheng, L
    Kolodgie, FD
    Carter, AJ
    Scott, DS
    Froehlich, J
    Virmani, R
    [J]. CIRCULATION, 2001, 104 (04) : 473 - 479
  • [10] GOODE J, 2003, FDA SUMMARY TAXUS EX, P1