Long-distance oxygen plasma sterilization: Effects and mechanisms

被引:65
作者
Liu, Hongxia [1 ,2 ]
Chen, Jierong [2 ]
Yang, Liqing [2 ]
Zhou, Yuan [2 ]
机构
[1] Xian Jiaotong Univ, Sch Life Sci & Technol, Xian 710049, Peoples R China
[2] Xian Jiaotong Univ, Dept Environm Sci & Engn, Xian 710049, Peoples R China
关键词
remote oxygen plasma; poly(tetrafluoroethylene); Escherichia coli; sterilization;
D O I
10.1016/j.apsusc.2007.07.152
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The distribution of electrons, ions and oxygen radicals in long-distance oxygen plasma and the germicidal effect (GE) of Escherichia coli on the surface of medical poly(tetrafluoroethylene) (PTFE) film were studied. The quantity of protein leakage and the production of lipid peroxide in bacterial suspension as well as the state of DNA were measured after sterilization to analyse the inactivation mechanisms. The results showed that the concentration of electrons and ions decreased rapidly with increasing the distance from the center of induction coil, which approximated to 0 at 30 cm, whereas the concentration of oxygen radicals reduced slowly, i.e. decreased 30% within 40 cm. GE value reached 3.42 in the active discharge zone (0 cm) and exceeded 3.32 within 40 cm when plasma treatment parameters were set as follows: plasma rf power at 100 W, treatment time at 60 s and oxygen flux at 40 cm(3)/min. Fast etching action on cell membrane by electrons, ions and attacking polyunsaturation fatty acid (PUFA) in cell membrane by oxygen radicals are primary reasons of oxygen plasma sterilization in the active discharge and the afterglow zone, respectively. The GE of UV radiation in long-distance oxygen plasma is feebleness. (C) 2007 Published by Elsevier B.V.
引用
收藏
页码:1815 / 1821
页数:7
相关论文
共 29 条
[1]   Plasma sterilization using glow discharge at atmospheric pressure [J].
Akitsu, T ;
Ohkawa, H ;
Tsuji, M ;
Kimura, H ;
Kogoma, M .
SURFACE & COATINGS TECHNOLOGY, 2005, 193 (1-3) :29-34
[2]   Chlorination and ozonation of waste-water:: comparative analysis of efficacy through the effect on Escherichia coli membranes [J].
Arana, I ;
Santorum, P ;
Muela, A ;
Barcina, I .
JOURNAL OF APPLIED MICROBIOLOGY, 1999, 86 (05) :883-888
[3]   Ontogeny of nitric oxide synthase activity and endotoxin-mediated damage in the neonatal rat colon [J].
Brown, JF ;
Tepperman, BL .
PEDIATRIC RESEARCH, 1997, 41 (05) :635-640
[4]  
CHANTAL EH, 2001, BIOMATERIALS, V22, P25
[5]  
CHEN JH, 2003, BIOCH EXPT, P63
[6]  
Chen JR, 2004, COMPOS INTERFACE, V11, P123
[7]  
CHEN QG, 2002, MED STAT, P104
[8]   Analysis of sterilization effect by pulsed dielectric barrier discharge [J].
Choi, JH ;
Han, I ;
Baik, HK ;
Lee, MH ;
Han, DW ;
Park, JC ;
Lee, IS ;
Song, KM ;
Lim, YS .
JOURNAL OF ELECTROSTATICS, 2006, 64 (01) :17-22
[9]   The influence of substrate material on bacteria sterilization in an oxygen plasma glow discharge [J].
Cvelbar, U. ;
Vujosevic, D. ;
Vratnica, Z. ;
Mozetic, M. .
JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2006, 39 (16) :3487-3493
[10]  
FANG YZ, 1989, RADICALS ENZYME, P63