Arthroscopic meniscal repair with an absorbable screw: results and surgical technique

被引:26
作者
Hantes, ME
Kotsovolos, ES
Mastrokalos, DS
Ammenwerth, J
Paessler, HH
机构
[1] Univ Thessalia, GR-41223 Larisa, Greece
[2] ATOS Clin, Ctr Knee Foot Surg & Sports Trauma, Heidelberg, Germany
关键词
meniscus repair; absorbable screw; Clearfix;
D O I
10.1007/s00167-004-0527-3
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The results of a new method for arthroscopic all-inside meniscus repair using a biodegradable cannulated screw (Clearfix meniscal screw) were assessed in a medium-term follow-up prospective study. The Clearfix meniscal screw system consists of delivery cannulae, screw driver, and screw implants. After tear debridement, a screw is located on the driver and passed through the cannula to the insertion site, holding the two sides of the tear together under linear compression. Forty-eight patients (48 repairs) with a mean age of 32.7 years were included in the study. Ligament stabilizing procedures were done in 39 patients (81%) who had anterior cruciate ligament deficient knees. Only longitudinal lesions in the red/red or red/white zone were repaired. Follow-up averaged 19 months, with a range from 12 to 48 months. Patients were evaluated using clinical examination, the "Orthopaedische Arbeitsgemeinschaft Knie (OAK)" knee evaluation scheme and magnetic resonance imaging (MRI). Criteria for clinical success included absence of joint-line tenderness, absence of swelling and a negative McMurray test. Postoperatively, there were no complications directly associated with the device. Twelve of 48 repaired menisci (25%) were considered failures according to the above-mentioned criteria. According to the OAK knee evaluation scheme, 38 patients (79%) had an excellent or good result. MRI, however, showed persisting grade III or IV lesions in 35 patients (73%). Analysis showed that age, length of tear, and simultaneous anterior cruciate ligament reconstruction did not affect the clinical outcome. In contrast, risk factors for failure of meniscus repair are chronicity of injury, location of tear more than 3 mm from the meniscosynovial junction and meniscus side (medial).
引用
收藏
页码:273 / 279
页数:7
相关论文
共 42 条
[1]
The arrow versus horizontal suture in arthroscopic meniscus repair - A prospective randomized study with arthroscopic evaluation [J].
Albrecht-Olsen, P ;
Kristensen, G ;
Burgaard, P ;
Joergensen, U ;
Toerholm, C .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 1999, 7 (05) :268-273
[2]
Albrecht-Olsen P, 1993, Knee Surg Sports Traumatol Arthrosc, V1, P104, DOI 10.1007/BF01565462
[3]
MICROVASCULATURE OF THE HUMAN MENISCUS [J].
ARNOCZKY, SP ;
WARREN, RF .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1982, 10 (02) :90-95
[4]
Tensile fixation strengths of absorbable meniscal repair devices as a function of hydrolysis time - An in vitro experimental study [J].
Arnoczky, SP ;
Lavagnino, M .
AMERICAN JOURNAL OF SPORTS MEDICINE, 2001, 29 (02) :118-123
[5]
MAGNETIC-RESONANCE SIGNALS IN HEALING MENISCI - AN EXPERIMENTAL-STUDY IN DOGS [J].
ARNOCZKY, SP ;
COOPER, TG ;
STADELMAIER, DM ;
HANNAFIN, JA .
ARTHROSCOPY, 1994, 10 (05) :552-557
[6]
Failure strength of repair devices versus meniscus suturing techniques [J].
Asik, M ;
Sener, N .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2002, 10 (01) :25-29
[7]
Arthroscopic meniscal repair using T-fix [J].
Asik, M ;
Sen, C ;
Erginsu, M .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2002, 10 (05) :284-288
[8]
COMPLICATIONS OF ARTHROSCOPIC MENISCAL REPAIR [J].
AUSTIN, KS ;
SHERMAN, OH ;
DEHAVEN, KE .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1993, 21 (06) :864-869
[9]
Barber F A, 1987, Arthroscopy, V3, P25, DOI 10.1016/S0749-8063(87)80006-3
[10]
Meniscus repair rehabilitation with concurrent anterior cruciate reconstruction [J].
Barber, FA ;
Click, SD .
ARTHROSCOPY, 1997, 13 (04) :433-437