Determination of the solute removal index for urea by using a partial spent dialysate collection method

被引:16
作者
Cheng, YL
Shek, CC
Wong, FKM
Choi, KS
Chau, KF
Ing, TS
Li, CS
机构
[1] Queen Elizabeth Hosp, Dept Med, Hong Kong, Peoples R China
[2] Queen Elizabeth Hosp, Dept Pathol, Hong Kong, Peoples R China
[3] Vet Affairs Hosp, Dept Med, Hines, IL USA
[4] Loyola Univ, Stritch Sch Med, Chicago, IL 60611 USA
关键词
solute removal index; urea; hemodialysis; partial spent dialysate collection;
D O I
10.1053/ajkd.1998.v31.pm9631843
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
In 22 hemodialysis patients, during a dialysis session, the solute removal index (SRI) for urea obtained from the use of a partial spent dialysate collection method was compared with that derived from the use of a total spent dialysate collection technique. The partial spent dialysate collection method was used to harvest a small representative sample of the fetal spent dialysate, The volumes of spent dialysate collected by the partial and the total spent dialysate collection methods were 1.7 +/- 0.4 L and 129.6 +/- 15.3 L, respectively, The total amount of urea nitrogen removed by dialysis as estimated by the partial spent dialysate collection method was similar to that determined by the total spent dialysate collection approach. As a result, the SRI value for urea obtained by the partial spent dialysate collection method (namely, 63% +/- 8%) correlated very well (r = 0.95, P < 0.001) with that derived by the total spent dialysate collection technique (namely, 62% +/- 8%). Our data suggest that it is feasible to use a simple partial spent dialysate collection method to obtain SRI results in patients treated with hemodialysis. (C) 1998 by the National Kidney Foundation, Inc.
引用
收藏
页码:986 / 990
页数:5
相关论文
共 26 条
  • [1] BANKHEAD MM, 1995, KIDNEY INT, V48, P785, DOI 10.1038/ki.1995.351
  • [2] Variation in blood sample collection for determination of hemodialysis adequacy
    Beto, JA
    Bansal, VK
    Ing, TS
    Daugirdas, JT
    [J]. AMERICAN JOURNAL OF KIDNEY DISEASES, 1998, 31 (01) : 135 - 141
  • [3] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [4] A partial dialysate collection method
    Cheng, YL
    Shek, CC
    Wong, AKW
    Wong, FKM
    Chau, KF
    Li, CS
    [J]. INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1997, 20 (01) : 14 - 17
  • [5] Daugirdas JT, 1994, HDB DIALYSIS, P92
  • [6] Depner TA, 1996, J AM SOC NEPHROL, V7, P464
  • [7] Garred L J, 1993, ASAIO J, V39, pM337
  • [8] KT/V AND PROTEIN CATABOLIC RATE DETERMINATION FROM SERIAL UREA MEASUREMENT IN THE DIALYSATE EFFLUENT STREAM
    GARRED, LJ
    DIGIUSEPPE, B
    CHAND, W
    MCCREADY, W
    CANAUD, B
    [J]. ARTIFICIAL ORGANS, 1992, 16 (03) : 248 - 255
  • [9] A MECHANISTIC ANALYSIS OF THE NATIONAL COOPERATIVE DIALYSIS STUDY (NCDS)
    GOTCH, FA
    SARGENT, JA
    [J]. KIDNEY INTERNATIONAL, 1985, 28 (03) : 526 - 534
  • [10] COLLECTION OF A REPRESENTATIVE FRACTION OF TOTAL SPENT HEMODIALYSATE
    ING, TS
    YU, AW
    WONG, FKM
    RAFIQ, M
    ZHOU, FQ
    DAUGIRDAS, JT
    [J]. AMERICAN JOURNAL OF KIDNEY DISEASES, 1995, 25 (05) : 810 - 812