Recovery, visualization, and analysis of actin and tubulin polymer flow in live cells: A fluorescent speckle microscopy study

被引:77
作者
Vallotton, P
Ponti, A
Waterman-Storer, CM
Salmon, ED
Danuser, G [1 ]
机构
[1] Swiss Fed Inst Technol, Biomech Lab, BioMicroMetr Grp, CH-8952 Schlieren, Switzerland
[2] Scripps Res Inst, Dept Cell Biol, La Jolla, CA 92037 USA
[3] Scripps Res Inst, Inst Childhood & Neglected Dis, La Jolla, CA 92037 USA
[4] Univ N Carolina, Dept Biol, Chapel Hill, NC 27599 USA
基金
美国国家卫生研究院;
关键词
D O I
10.1016/S0006-3495(03)74564-0
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Fluorescent speckle microscopy (FSM) is becoming the technique of choice for analyzing in vivo the dynamics of polymer assemblies, such as the cytoskeleton. The massive amount of data produced by this method calls for computational approaches to recover the quantities of interest; namely, the polymerization and depolymerization activities and the motions undergone by the cytoskeleton over time. Attempts toward this goal have been hampered by the limited signal-to-noise ratio of typical FSM data, by the constant appearance and disappearance of speckles due to polymer turnover, and by the presence of flow singularities characteristic of many cytoskeletal polymer assemblies. To deal with these problems, we present a particle-based method for tracking fluorescent speckles in time-lapse FSM image series, based on ideas from operational research and graph theory. Our software delivers the displacements of thousands of speckles between consecutive frames, taking into account that speckles may appear and disappear. In this article we exploit this information to recover the speckle flow field. First, the software is tested on synthetic data to validate our methods. We then apply it to mapping filamentous actin retrograde flow at the front edge of migrating newt lung epithelial cells. Our results confirm findings from previously published kymograph analyses and manual tracking of such FSM data and illustrate the power of automated tracking for generating complete and quantitative flow measurements. Third, we analyze microtubule poleward flux in mitotic metaphase spindles assembled in Xenopus egg extracts, bringing new insight into the dynamics of microtubule assemblies in this system.
引用
收藏
页码:1289 / 1306
页数:18
相关论文
共 61 条
  • [1] Alberts B., 2008, MOL BIOL CELL
  • [2] [Anonymous], 1997, FRONT BIOSCI LANDMAR, DOI DOI 10.2741/A189
  • [4] Cytoskeletal mechanisms of neuronal degeneration
    Brandt, R
    [J]. CELL AND TISSUE RESEARCH, 2001, 305 (02) : 255 - 265
  • [5] Bulinski JC, 2001, J CELL SCI, V114, P3885
  • [6] Speckle microscopic evaluation of microtubule transport in growing nerve processes
    Chang, SH
    Svitkina, TM
    Borisy, GG
    Popov, SV
    [J]. NATURE CELL BIOLOGY, 1999, 1 (07) : 399 - 403
  • [7] Quantitative comparison of algorithms for tracking single fluorescent particles
    Cheezum, MK
    Walker, WF
    Guilford, WH
    [J]. BIOPHYSICAL JOURNAL, 2001, 81 (04) : 2378 - 2388
  • [8] Lamellipodia in invasion
    Condeelis, JS
    Wyckoff, JB
    Bailly, M
    Pestell, R
    Lawrence, D
    Backer, J
    Segall, JE
    [J]. SEMINARS IN CANCER BIOLOGY, 2001, 11 (02) : 119 - 128
  • [9] Dense estimation of fluid flows
    Corpetti, T
    Mémin, É
    Pérez, P
    [J]. IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 2002, 24 (03) : 365 - 380
  • [10] Microcontact printing of novel co-polymers in combination with proteins for cell-biological applications
    Csucs, G
    Michel, R
    Lussi, JW
    Textor, M
    Danuser, G