A microangiographic technique using synchrotron radiation to visualize dermal circulation in vivo

被引:8
作者
Ito, K
Tanaka, E
Mori, H
Nakazawa, H
Tanino, R
机构
[1] Tokai Univ, Sch Med, Dept Plast & Reconstruct Surg, Hiratsuka, Kanagawa 25912, Japan
[2] Tokai Univ, Sch Med, Dept Physiol, Hiratsuka, Kanagawa 25912, Japan
关键词
D O I
10.1097/00006534-199809040-00032
中图分类号
R61 [外科手术学];
学科分类号
摘要
Conventional angiography cannot resolve dermal small vessels with a diameter of 200 mu m or less. In vitro microangiography is currently characterized by better spatial resolution than conventional angiography but does not allow visualization of the blood stream in dermal vessels in vivo. In this study, we introduce a novel synchrotron radiation microangiographic system for visualizing the structure of and blood flow in dermal microvessels in vivo repeatedly. We used monochromatic synchrotron radiation with an energy just above the k-edge of iodine (33.3 keV) as an x-ray and a high-definition television camera system with a high-sensitivity image pick-up tube for detection. The 33.3-keV monochromatic synchrotron radiation allows detection of a small amount of iodine, and the high-definition television camera system can resolve small vessels with high-spatial resolution and no loss of sensitivity. We performed synchrotron radiation angiography of superficial inferior epigastric arteries and their branches in nine rats, and of the caudal artery in 14 rats, and compared angiographic images taken by the current system with those taken by a conventional angiographic system in seven rats. With this new microangiographic technique, we could visualize small dermal vessels with a diameter as low as 50 mu m. In addition, repeated angiograms at baseline and under increasing body temperature could be obtained. This new microangiographic approach is expected to be very useful for the assessment of dermal circulation in patients.
引用
收藏
页码:1128 / 1133
页数:6
相关论文
共 16 条
[1]   THE VASCULAR TERRITORIES OF THE SUPERIOR EPIGASTRIC AND THE DEEP INFERIOR EPIGASTRIC SYSTEMS [J].
BOYD, JB ;
TAYLOR, GI ;
CORLETT, R .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1984, 73 (01) :1-14
[2]   THE V-Y PLANTAR FLAP FOR RECONSTRUCTION OF THE FOREFOOT [J].
COLEN, LB ;
REPLOGLE, SL ;
MATHES, SJ .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1988, 81 (02) :220-227
[3]  
HALLOCK GG, 1995, PLAST RECONSTR SURG, V96, P1351, DOI 10.1097/00006534-199511000-00018
[4]  
HYODO K, 1991, SYNCHROTRON RAD HDB, P55
[5]   THE MICROCIRCULATORY PATTERN OF THE TRANSVERSE-ABDOMINAL FLAP - A CROSS-SECTIONAL XEROGRAPHIC AND CAT SCANNING STUDY [J].
KAUFMAN, T ;
HURWITZ, DJ ;
BOEHNKE, M ;
FUTRELL, JW .
ANNALS OF PLASTIC SURGERY, 1985, 14 (04) :340-345
[6]   The vascular anatomy of the inner anterior abdominal wall with special reference to the transversus and rectus abdominis musculoperitoneal (TRAMP) composite flap for vaginal reconstruction [J].
Konerding, MA ;
Gaumann, A ;
Shumsky, A ;
Schlenger, K ;
Hockel, M .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1997, 99 (03) :705-710
[7]   Small-vessel radiography in situ with monochromatic synchrotron radiation [J].
Mori, H ;
Hyodo, K ;
Tanaka, E ;
UddinMohammed, M ;
Yamakawa, A ;
Shinozaki, Y ;
Nakazawa, H ;
Tanaka, Y ;
Sekka, T ;
Iwata, Y ;
Handa, S ;
Umetani, K ;
Ueki, H ;
Yokoyama, T ;
Tanioka, K ;
Kubota, M ;
Hosaka, H ;
Ishikawa, N ;
Ando, M .
RADIOLOGY, 1996, 201 (01) :173-177
[8]   VISUALIZATION OF PENETRATING TRANSMURAL ARTERIES IN-SITU BY MONOCHROMATIC SYNCHROTRON-RADIATION [J].
MORI, H ;
HYODO, K ;
TOBITA, K ;
CHUJO, M ;
SHINOZAKI, Y ;
SUGISHITA, Y ;
ANDO, M .
CIRCULATION, 1994, 89 (02) :863-871
[9]   TOXICOLOGICAL SAFETY ASSESSMENT OF IOMEPROL, A NEW X-RAY CONTRAST AGENT [J].
MORISETTI, A ;
TIRONE, P ;
LUZZANI, F ;
DEHAEN, C .
EUROPEAN JOURNAL OF RADIOLOGY, 1994, 18 :S21-S31
[10]   A SIMPLIFIED LEAD-OXIDE CADAVER INJECTION TECHNIQUE [J].
REES, MJW ;
TAYLOR, GI .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1986, 77 (01) :141-145