NIST-F1: recent improvements and accuracy evaluations

被引:167
作者
Heavner, TP [1 ]
Jefferts, SR [1 ]
Donley, EA [1 ]
Shirley, JH [1 ]
Parker, TE [1 ]
机构
[1] Natl Inst Stand & Technol, Div Time & Frequency, Boulder, CO 80305 USA
关键词
D O I
10.1088/0026-1394/42/5/012
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In the last several years we have made many improvements to NIST-Fl (a laser-cooled Cs fountain primary frequency standard at the National Institute of Standards and Technology (NIST) in Boulder, Colorado) resulting in a reduction by over a factor of 2 in the uncertainty of the realization of the SI second. The two most recent accuracy evaluations of NIST-FI had combined standard fractional uncertainties of 0.61 x 10(-15) (June 2004) and 0.53 x 10(-15) (January 2005), which were Submitted to the Bureau International des Poids et Mesures with total fractional uncertainties (including time-transfer contributions) of, respectively, 0.88 X 10(-15) and 0.97 x 10(-15). Here we discuss the improvements and evaluation methods and present an updated uncertainty budget.
引用
收藏
页码:411 / 422
页数:12
相关论文
共 25 条
[1]   PRESSURE, LIGHT, AND TEMPERATURE SHIFTS IN OPTICAL DETECTION OF 0-0 HYPERFINE RESONANCE OF ALKALI METALS [J].
ARDITI, M ;
CARVER, TR .
PHYSICAL REVIEW, 1961, 124 (03) :800-&
[2]   HYPERFINE PRESSURE SHIFT OF CS-133-ATOMS IN NOBLE AND MOLECULAR BUFFER GASES [J].
BEER, CW ;
BERNHEIM, RA .
PHYSICAL REVIEW A, 1976, 13 (03) :1052-1057
[3]   Cavity frequency pulling in cold atom fountains [J].
Bize, S ;
Sortais, Y ;
Mandache, C ;
Clairon, A ;
Salomon, C .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2001, 50 (02) :503-506
[4]   Controlling the cold collision shift in high precision atomic interferometry [J].
Dos Santos, FP ;
Marion, H ;
Bize, S ;
Sortais, Y ;
Clairon, A ;
Salomon, C .
PHYSICAL REVIEW LETTERS, 2002, 89 (23) :1-233004
[5]   Measurement and cancellation of the cold collision frequency shift in an 87Rb fountain clock [J].
Fertig, C ;
Gibble, K .
PHYSICAL REVIEW LETTERS, 2000, 85 (08) :1622-1625
[6]  
Howe DA, 2003, P IEEE INT FREQ CONT, P233
[7]   Measurement of dynamic end-to-end cavity phase shifts in cesium-fountain frequency standards [J].
Jefferts, SR ;
Heavner, TP ;
Donley, EA ;
Parker, TE .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2004, 51 (06) :652-653
[8]   Accuracy evaluation of NIST-F1 [J].
Jefferts, SR ;
Shirley, J ;
Parker, TE ;
Heavner, TP ;
Meekhof, DM ;
Nelson, C ;
Levi, F ;
Costanzo, G ;
De Marchi, A ;
Drullinger, R ;
Hollberg, L ;
Lee, WD ;
Walls, FL .
METROLOGIA, 2002, 39 (04) :321-336
[9]  
JEFFERTS SR, 2005, IN PRESS P 19 EUR TI
[10]  
JEFFERTS SR, 2005, IN PRESS IEEE T ULTR