Reliability of intraocular pressure measurements after myopic excimer photorefractive keratectomy

被引:56
作者
Abbasoglu, KE [1 ]
Bowman, RW [1 ]
Cavanagh, HD [1 ]
McCulley, JP [1 ]
机构
[1] Univ Texas, SW Med Ctr, Dept Ophthalmol, Dallas, TX 75235 USA
关键词
D O I
10.1016/S0161-6420(98)91215-5
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Objective: To determine the reliability of intraocular pressure (IOP) measurements by Goldmann applanation tonometry and pneumotonometry in eyes treated with excimer myopic photorefractive keratectomy (PRK), Design: A prospective case series. Participants: Forty consecutive eyes treated with PRK were evaluated. Intervention and Main Outcome Measures: Central and peripheral corneal Goldmann tonometry and pneumotonometry measurements were done before surgery, at 1 week, and at I and 3 months after surgery. Results: The IOP by Goldmann tonometry from the central cornea was significantly lower than the peripheral IOP; however, there was no difference between IOP measured from central and peripheral corneas by pneumotonometry, which, in turn, correlated with peripheral Goldmann measurements. There was a trend, but not a statistically significant correlation, between the spherical equivalent of the treatment and the amount of decrease in central Goldmann IOP. Conclusions: Pneumotonometry measures the IOP reliably after PRK from all parts of the cornea, whereas central Goldmann tonometry underestimates the IOP by 2.40 +/- 1.23 mmHg.
引用
收藏
页码:2193 / 2196
页数:4
相关论文
共 25 条
[1]   TOPICAL CORTICOSTEROIDS + HEREDITY IN PRIMARY OPEN-ANGLE GLAUCOMA [J].
BECKER, B ;
HAHN, KA .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1964, 57 (04) :543-&
[2]   Reduction in intraocular pressure after excimer laser photorefractive keratectomy - Correlation with pretreatment myopia [J].
Chatterjee, A ;
Shah, S ;
Bessant, DA ;
Naroo, SA ;
Doyle, SJ .
OPHTHALMOLOGY, 1997, 104 (03) :355-359
[3]  
EHLERS N, 1975, ACTA OPHTHALMOL, V53, P34
[4]  
HANSEN FK, 1971, ACTA OPHTHALMOL, V49, P82
[5]  
HJORTDAL JO, 1995, ACTA OPHTHALMOL SCAN, V73, P18
[6]  
Hjortdal JO, 1996, J REFRACT SURG, V12, P459
[7]   VALIDITY OF MACKAY-MARG ELECTRONIC APPLANATION TONOMETER IN PATIENTS WITH SCARRED IRREGULAR CORNEAS [J].
KAUFMAN, HE ;
WIND, CA ;
WALTMAN, SR .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1970, 69 (06) :1003-&
[8]  
Kwitko M L, 1996, Ophthalmic Surg Lasers, V27, pS454
[9]  
LEIBOWITZ HM, 1984, CORNEAL DISORDERS CL, P14
[10]   INTRAOCULAR-PRESSURE MEASUREMENT AFTER PENETRATING KERATOPLASTY - MINIFIED GOLDMANN APPLANATION TONOMETER, PNEUMATONOMETER, AND TONO-PEN VERSUS MANOMETRY [J].
MENAGE, MJ ;
KAUFMAN, PL ;
CROFT, MA ;
LANDAY, SP .
BRITISH JOURNAL OF OPHTHALMOLOGY, 1994, 78 (09) :671-676