Detection of volatile compounds emitted by Pseudomonas aeruginosa using selected ion flow tube mass spectrometry

被引:122
作者
Carroll, W
Lenney, W
Wang, TS
Spanel, P
Alcock, A
Smith, D
机构
[1] Univ Hosp N Staffordshire, Acad Dept Paediat, Dept Microbiol, Stoke On Trent ST4 6QG, Staffs, England
[2] Keele Univ, Sch Med, Inst Sci & Technol Med, Stoke On Trent, Staffs, England
[3] Acad Sci Czech Republ, J Heyrovsky Inst Phys Chem, V Cermak Lab, Prague, Czech Republic
关键词
Pseudomonas aeruginosa; hydrogen cyanide; biomarkers; SIFT-MS;
D O I
10.1002/ppul.20170
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Pseudomonas aeruginosa (PA) is associated with a distinctive smell produced by a combination of volatile compounds (VCs). Selected ion flow tube mass spectrometry (SIFT-MS) provides a novel and rapid methodology for rapid, accurate detection of trace quantities (parts per billion; ppb) of VCs in air. We studied the VCs produced by different isolates of PA cultures in vitro from patients with cystic fibrosis. Twenty-one patients with cystic fibrosis provided sputum and cough swab samples for culture. These were used to inoculate blood agar (BA) and Pseudomonas-selective media (PSM). These plates were incubated for 48 hr at 37 degrees C inside sealed plastic bags. The air surrounding the samples after 48 hr (headspace) was analyzed using SIFT-MS. PA growth was commonly associated with the production of significant quantities of VCs, notably hydrogen cyanide gas (HCN). This was detectable in the headspace of 15/22 of PA-positive samples. In contrast, it was only seen in the headspace of 1/13 control samples (6 sterile plates and 7 plates with only mixed upper respiratory tract flora). The concentration of HCN was significantly higher above PA-positive samples than above other bacterial growth (P < 0.01), and in our study, levels of HCN greater than 100 ppb were a sensitive (68%) and highly specific (100%) biomarker of PA. SIFT-MS can detect a range of VCs from PA in vitro. HCN may be a specific indicator of PA infection in vivo, and offers promise as a biomarker for noninvasive detection of PA infection by breath analysis. (c) 2005 Wiley-Liss, Inc.
引用
收藏
页码:452 / 456
页数:5
相关论文
共 30 条
[1]   Quantification of acetonitrile in exhaled breath and urinary headspace using selected ion flow tube mass spectrometry [J].
Abbott, SM ;
Elder, JB ;
Spanel, P ;
Smith, D .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2003, 228 (2-3) :655-665
[2]   Mechanism, regulation, and ecological role of bacterial cyanide biosynthesis [J].
Blumer, C ;
Haas, D .
ARCHIVES OF MICROBIOLOGY, 2000, 173 (03) :170-177
[3]   INFLUENCE OF OXYGEN ON THE PSEUDOMONAS-AERUGINOSA HYDROGEN-CYANIDE SYNTHASE [J].
CASTRIC, P .
CURRENT MICROBIOLOGY, 1994, 29 (01) :19-21
[4]   GLYCINE METABOLISM BY PSEUDOMONAS-AERUGINOSA - HYDROGEN-CYANIDE BIOSYNTHESIS [J].
CASTRIC, PA .
JOURNAL OF BACTERIOLOGY, 1977, 130 (02) :826-831
[5]   RELATIONSHIP BETWEEN GROWTH-PHASE AND CYANOGENESIS IN PSEUDOMONAS-AERUGINOSA [J].
CASTRIC, PA ;
EBERT, RF ;
CASTRIC, KF .
CURRENT MICROBIOLOGY, 1979, 2 (05) :287-292
[6]  
COX CD, 1979, J CLIN MICROBIOL, V9, P479
[7]   Use of cough swabs in a cystic fibrosis clinic [J].
Equi, AC ;
Pike, SE ;
Davies, J ;
Bush, A .
ARCHIVES OF DISEASE IN CHILDHOOD, 2001, 85 (05) :438-439
[8]  
Frederiksen B, 1997, PEDIATR PULM, V23, P330, DOI 10.1002/(SICI)1099-0496(199705)23:5<330::AID-PPUL4>3.0.CO
[9]  
2-O
[10]   CYANIDE PRODUCTION BY PSEUDOMONAS AERUGINOSA [J].
GOLDFARB, WB ;
HARGRAF, H .
ANNALS OF SURGERY, 1967, 165 (01) :104-&