Comparison of surfactants for dynamic surface modification of poly(dimethylsiloxane) microchips

被引:80
作者
Garcia, CD [1 ]
Dressen, BM [1 ]
Henderson, A [1 ]
Henry, CS [1 ]
机构
[1] Colorado State Univ, Dept Chem, Ft Collins, CO 80523 USA
关键词
biomolecules; electrochemical detection; microchip capillary electrophoresis; miniaturization; pulsed amperometric detection; surfactants;
D O I
10.1002/elps.200410290
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In the present report, the use of negatively charged surfactants as modifiers of the background electrolyte is reported using poly(dimethylsiloxane) (PDMS) microchips. In particular, the use of anionic surfactants, such as sodium dodecyl sulfate, phosphatidic acid, and deoxycholate, was studied. When surfactants were present in the run buffer, an increase in the electroosmotic flow (EOF) was observed. Two additional effects were also observed: (i) stabilization of the run-to-run EOF, (ii) an improvement in the electrochemical response for several biomolecules. In order to characterize the analysis conditions, the effects of different surfactant, electrolyte, and pH were studied. EOF measurements were performed using either the current monitoring method or by detection of a neutral molecule. The first adsorption/desorption kinetics studies are also reported for different surfactants onto PDMS. The separation of biologically important analytes (glucose, penicillin, phenol, and homovanillic acid) was improved decreasing the analysis time from 200 to 125 s. However, no significant changes in the number of theoretical plates were observed.
引用
收藏
页码:703 / 709
页数:7
相关论文
共 37 条
[31]  
Ocvirk G, 2000, ELECTROPHORESIS, V21, P107, DOI 10.1002/(SICI)1522-2683(20000101)21:1<107::AID-ELPS107>3.0.CO
[32]  
2-Y
[33]   Experimental studies of electroosmotic flow dynamics in microfabricated devices during current monitoring experiments [J].
Pittman, JL ;
Henry, CS ;
Gilman, SD .
ANALYTICAL CHEMISTRY, 2003, 75 (03) :361-370
[34]   Carbohydrate analysis of bacterial polysaccharides by high-pH anion-exchange chromatography and online polarimetric determination of absolute configuration [J].
Stroop, CJM ;
Bush, CA ;
Marple, RL ;
LaCourse, WR .
ANALYTICAL BIOCHEMISTRY, 2002, 303 (02) :176-185
[35]   AMPEROMETRIC DETECTION OF CATECHOLS IN CAPILLARY ZONE ELECTROPHORESIS WITH NORMAL AND MICELLAR SOLUTIONS [J].
WALLINGFORD, RA ;
EWING, AG .
ANALYTICAL CHEMISTRY, 1988, 60 (03) :258-263
[36]   Microchip capillary electrophoresis with electrochemical detector for fast measurements of aromatic amino acids [J].
Wang, J ;
Chen, G .
TALANTA, 2003, 60 (06) :1239-1244
[37]   Electrochemical detection for microscale analytical systems: a review [J].
Wang, J .
TALANTA, 2002, 56 (02) :223-231