Ultrasensitive electrochemical immunoassay for BRCA1 using BMIM•BF4-coated SBA-15 as labels and functionalized graphene as enhancer

被引:100
作者
Cai, Yanyan [1 ]
Li, He [1 ,2 ]
Du, Bin [1 ]
Yang, Minghui [1 ]
Li, Yan [1 ]
Wu, Dan [1 ]
Zhao, Yanfang [1 ]
Dai, Yuxue [1 ]
Wei, Qin [1 ]
机构
[1] Univ Jinan, Sch Chem & Chem Engn, Jinan 250022, Peoples R China
[2] Univ Jinan, Sch Med & Life Sci, Jinan 250022, Peoples R China
关键词
SBA-15; Horseradish peroxidase; Amperometric immunosensor; Ionic liquid; Graphene nanocomposites; Breast cancer susceptibility gene; AMPEROMETRIC GLUCOSE BIOSENSOR; TEMPERATURE IONIC LIQUID; MESOPOROUS SILICA; ENZYME IMMOBILIZATION; AQUEOUS DISPERSIONS; MODIFIED ELECTRODE; GRAPHITE OXIDE; OVARIAN-CANCER; NANOPARTICLES; ENCAPSULATION;
D O I
10.1016/j.biomaterials.2010.11.058
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
BRCA1 is an anti-oncogene in women, who are genetically predisposed to breast and ovary cancer. The detection of BRCA1 can offer an opportunity to characterize the function of genetic features in breast and ovarian cancer and to screen breast or ovarian cancer patients. In this study, we designed a new label and fabricated a novel sandwich-type electrochemical immunoassay for the ultrasensitive detection of BRCA1 Horseradish peroxidase (HRP) was entrapped in the pores of amino-group functionalized SBA-15 and the secondary antibody (Ab(2)) combined with SBA-15 by covalent bond. Ionic liquid (IL) was added into the mixed solution of SBA-15/HRP/Ab(2) and application of IL increased the electrochemical activity of HRP and promoted electron transport. The synergistic effect between IL SBA-15, Ab(2) and HRP could retain the bioactivity of HRP and Ab(2). The sensitivity of the sandwich-type immunosensor using SBA-15/HRP/Ab(2)/BMIM. BF4 as labels for BRCA1 detection was much higher than that using either SBA-15/HRP/Ab(2) or SBA-15/Ab(2) as labels. Under optimal conditions, the electrochemical immunoassay exhibited a wide working range from 0.01 to 15 ng/mL with a detection limit of 4.86 pg/mL BRCA1. The precision, reproducibility, and stability of the immunoassay were acceptable. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2117 / 2123
页数:7
相关论文
共 46 条
[41]   Ultrasensitive potentiometric immunosensor based on SA and OCA techniques for immobilization of HBsAb with colloidal Au and polyvinyl butyral as matrixes [J].
Yuan, R ;
Tang, DP ;
Chai, YQ ;
Zhong, X ;
Liu, Y ;
Dai, JY .
LANGMUIR, 2004, 20 (17) :7240-7245
[42]   Design and Implementation of Electrochemical Cytosensor for Evaluation of Cell Surface Carbohydrate and Glycoprotein [J].
Zhang, Jing-Jing ;
Cheng, Fang-Fang ;
Zheng, Ting-Ting ;
Zhu, Jun-Jie .
ANALYTICAL CHEMISTRY, 2010, 82 (09) :3547-3555
[43]   Triblock copolymer syntheses of mesoporous silica with periodic 50 to 300 angstrom pores [J].
Zhao, DY ;
Feng, JL ;
Huo, QS ;
Melosh, N ;
Fredrickson, GH ;
Chmelka, BF ;
Stucky, GD .
SCIENCE, 1998, 279 (5350) :548-552
[44]   Nonionic triblock and star diblock copolymer and oligomeric surfactant syntheses of highly ordered, hydrothermally stable, mesoporous silica structures [J].
Zhao, DY ;
Huo, QS ;
Feng, JL ;
Chmelka, BF ;
Stucky, GD .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1998, 120 (24) :6024-6036
[45]   Direct electrochemistry of hemoglobin on a room temperature ionic liquid modified electrode and its electrocatalytic activity for the reduction of oxygen [J].
Zhao, Guang-Chao ;
Xu, Miao-Qing ;
Ma, Juan ;
Wei, Xian-Wen .
ELECTROCHEMISTRY COMMUNICATIONS, 2007, 9 (05) :920-924
[46]   The direct electrochemistry behavior of Cyt c on the modified glassy carbon electrode by SBA-15 with a high-redox potential [J].
Zhu, Lin ;
Wang, Kunqi ;
Lu, Tianhong ;
Xing, Wei ;
Li, Jing ;
Yang, Xiangguang .
JOURNAL OF MOLECULAR CATALYSIS B-ENZYMATIC, 2008, 55 (1-2) :93-98