Quantification of meropenem in plasma and cerebrospinal. fluid by micellar electrokinetic capillary chromatography and application in bacterial meningitis patients

被引:32
作者
Chou, Yu-Wei
Yang, Yuan-Han
Chen, Jin-Hon
Kuo, Chen-Chun
Chen, Su-Hwei [1 ]
机构
[1] Kaohsiung Med Univ, Sch Pharm, Grad Inst Pharmaceut Sci, Kaohsiung 807, Taiwan
[2] Kaohsiung Med Univ Hosp, Dept Neurol, Kaohsiung 807, Taiwan
[3] Kaohsiung Med Univ Hosp, Dept Pharm, Kaohsiung 807, Taiwan
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2007年 / 856卷 / 1-2期
关键词
meropenem; plasma and cerebrospinal fluid; MEKC; bacterial meningitis;
D O I
10.1016/j.jchromb.2007.06.015
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A high-performance micellar electrokinetic capillary chromatography (MEKC) has been demonstrated for the determination of meropenem in human plasma and in cerebrospinal fluid (CSF) and application in meningitis patients after intravenous (IV) administration. Plasma sample was pretreated by means of solid-phase extraction (SPE) on C-18 cartridge and CSF sample was by direct injection without sample pretreatment, with subsequent quantitation by MEKC. The separation of meropenem was carried out in an untreated fused-silica capillary (40.2 cm x 50 mu m I.D., effective length 30 cm) and was performed at 25 degrees C using a background electrolyte consisting of Tris buffer (40 mM, pH 8.0) solution with sodium dodecyl sulfate (SDS) as the running buffer and on-column detection at 300 nm. Several parameters affecting the separation and sensitivity of the drug were studied, including pH, the concentrations of Tris buffer and surfactant. Using cefotaxime as an internal standard (IS), the linear ranges of the method for the determination of meropenem in plasma and in CSF were all over 0.5-50 mu g/mL; the detection limits (signal-to-noise ratio = 3) of meropenem in plasma and in CSF were 0.2 mu g/mL and 0.3 mu g/mL, respectively. (C) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:294 / 301
页数:8
相关论文
共 20 条
[1]  
ALTRIA KD, 1996, CAPILLARY ELECTROPHO, P7
[2]   Determination and pharmacokinetic study of meropenem in rat bile using on-line microdialysis and liquid chromatography [J].
Chang, YL ;
Chou, MH ;
Lin, MF ;
Chen, CF ;
Tsai, TH .
JOURNAL OF CHROMATOGRAPHY A, 2002, 961 (01) :119-124
[3]   PHARMACOKINETICS OF MEROPENEM IN SUBJECTS WITH VARIOUS DEGREES OF RENAL IMPAIRMENT [J].
CHRISTENSSON, BA ;
NILSSONEHLE, I ;
HUTCHISON, M ;
HAWORTH, SJ ;
OQVIST, B ;
NORRBY, SR .
ANTIMICROBIAL AGENTS AND CHEMOTHERAPY, 1992, 36 (07) :1532-1537
[4]  
EDWARDS JR, 1995, J INFECT DIS S, V96, P5
[5]   Rapid antibiotic drug monitoring:: Meropenem and ceftazidime determination in serum and bronchial secretions by high-performance liquid chromatography-integrated sample preparation [J].
Ehrlich, M ;
Daschner, FD ;
Kümmerer, K .
JOURNAL OF CHROMATOGRAPHY B, 2001, 751 (02) :357-363
[6]   High-performance liquid chromatographic assay for meropenem in serum [J].
Elkhaili, H ;
Niedergang, S ;
Pompei, D ;
Linger, L ;
Leveque, D ;
Jehl, F .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 1996, 686 (01) :19-26
[7]   High performance liquid chromatography method for the determination of meropenem in human plasma [J].
Farin, D ;
Kitzes-Cohen, R ;
Piva, G ;
Gozlan, I .
CHROMATOGRAPHIA, 1999, 49 (5-6) :253-255
[8]  
HARDMAN JG, 2001, GOODMAN GILMANS PHAR, P1214
[9]   Determination of meropenem by capillary electrophoresis using direct injection of serum [J].
Kitahashi, T ;
Furuta, I .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2005, 43 (08) :430-433
[10]   Pharmacokinetics of meropenem in critically ill patients with acute renal failure treated by continuous hemodiafiltration [J].
Krueger, WA ;
Schroeder, TH ;
Hutchison, M ;
Hoffmann, E ;
Dieterich, HJ ;
Heininger, A ;
Erley, C ;
Wehrle, A ;
Unertl, K .
ANTIMICROBIAL AGENTS AND CHEMOTHERAPY, 1998, 42 (09) :2421-2424