Rationale and Objectives. MRI has shown promise in assessing breast cancer patients undergoing neoadjuvant chemotherapy. Computer-aided detection (CAD) for MRI can automatically display tumor enhancement parameters. This study was performed to determine the utility of CAD applied to breast MRI in this patient population. Materials and Methods. Fifteen patients with 16 newly diagnosed locally advanced breast cancers were evaluated with MRI before and after neoadjuvant chemotherapy. CAD assessments, including presence or absence of significant enhancement, enhancement profiles, and maximum sizes, were recorded. Pre-chemotherapy and post-chemotherapy enhancement profiles were compared. Sizes were compared to those measured by the radiologist and at final pathology. Results. Prior to chemotherapy, all tumors demonstrated CAD-assessed significant enhancement. Following chemotherapy, 7/16 tumors showed no residual significant enhancement, but all had residual disease at pathology. In those patients with residual enhancement, comparison of the post-chemotherapy to pre-chemotherapy CAD enhancement profiles showed a significant decrease in percentage of washout enhancement (P = 0.0147) in patients with less than 5 mm of residual microscopic disease. Radiologist-measured tumor sizes demonstrated better correlation with sizes at pathology (r = 0.60) than did CAD-generated tumor sizes (r = 0.32). Conclusion. CAD may be helpful in assessing changes in MRI enhancement profiles of tumors following chemotherapy. However, CAD-assessed significant enhancement following chemotherapy can be falsely negative for residual malignancy, and CAD tumor sizes are less accurate than those measured by the radiologist in predicting size of residual malignancy. CAD may complement but should not replace the radiologist's assessment of tumors in this patient population.
引用
收藏
页码:806 / 814
页数:9
相关论文
共 33 条
[1]  
Abraham DC, 1996, CANCER, V78, P91, DOI 10.1002/(SICI)1097-0142(19960701)78:1<91::AID-CNCR14>3.0.CO
[2]  
2-2
[3]  
American College of Radiology (ACR), 2003, BREAST IM ATL
[4]   Imaging in evaluation of response to neoadjuvant breast cancer treatment benefits of MRI [J].
Balu-Maestro, C ;
Chapellier, C ;
Bleuse, A ;
Chanalet, I ;
Chauvel, C ;
Largillier, R .
BREAST CANCER RESEARCH AND TREATMENT, 2002, 72 (02) :145-152
[5]  
Chen X, 2004, AM J ROENTGENOL, V182, P33
[6]   Combined use of MRI and PET to monitor response and assess residual disease for locally advanced breast cancer treated with neoadjuvant chemotherapy [J].
Chen, XM ;
Moore, MO ;
Lehman, CD ;
Mankoff, DA ;
Lawton, TJ ;
Peacock, S ;
Schubert, EK ;
Livingston, RB .
ACADEMIC RADIOLOGY, 2004, 11 (10) :1115-1124
[7]   Monitoring the size and response of locally advanced breast cancers to neoadjuvant chemotherapy (weekly paclitaxel and epirubicin) with serial enhanced MRI [J].
Cheung, YC ;
Chen, SC ;
Su, MY ;
See, LC ;
Hsueh, S ;
Chang, HK ;
Lin, YC ;
Tsai, CS .
BREAST CANCER RESEARCH AND TREATMENT, 2003, 78 (01) :51-58
[8]   Utility of magnetic resonance imaging in the management of breast cancer: Evidence for improved preoperative staging [J].
Esserman, L ;
Hylton, N ;
Yassa, L ;
Barclay, J ;
Frankel, S ;
Sickles, E .
JOURNAL OF CLINICAL ONCOLOGY, 1999, 17 (01) :110-119
[9]   MRI phenotype is associated with response to doxorubicin and cyclophosphamide neoadjuvant chemotherapy in stage III breast cancer [J].
Esserman, L ;
Kaplan, E ;
Partridge, S ;
Tripathy, D ;
Rugo, H ;
Park, J ;
Hwang, S ;
Kuerer, H ;
Sudilovsky, D ;
Lu, Y ;
Hylton, N .
ANNALS OF SURGICAL ONCOLOGY, 2001, 8 (06) :549-559
[10]  
Harms SE, 1999, JMRI-J MAGN RESON IM, V10, P991, DOI 10.1002/(SICI)1522-2586(199912)10:6<991::AID-JMRI16>3.0.CO