Evaluation of an immunomagnetic separation assay in combination with cultivation to improve Legionella pneumophila serogroup 1 recovery from environmental samples

被引:17
作者
Allegra, S. [1 ]
Girardot, F. [1 ]
Grattard, F. [1 ]
Berthelot, P. [1 ]
Helbig, J. H. [2 ]
Pozzetto, B. [1 ]
Riffard, S. [1 ]
机构
[1] Univ St Etienne, Grp Immunite Muqueuses & Agents Pathogenes, EA 3064, Fac Med,Univ Lyon, F-42023 St Etienne 02, France
[2] Tech Univ Dresden, Inst Med Microbiol & Hyg, Fac Med, Dresden, Germany
关键词
culture; environmental samples; immunomagnetic separation; Legionella; monoclonal antibody; ESCHERICHIA-COLI O157-H7; CRYPTOSPORIDIUM-PARVUM OOCYSTS; SOLID-PHASE CYTOMETRY; HOT-WATER SYSTEMS; RAPID DETECTION; FLOW-CYTOMETRY; MONOCLONAL-ANTIBODIES; TIME PCR; QUANTITATIVE DETECTION; MYCOBACTERIUM-AVIUM;
D O I
10.1111/j.1365-2672.2011.04955.x
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 [微生物学]; 090105 [作物生产系统与生态工程];
摘要
Aims: Legionella isolation from environmental samples is often difficult because of the presence of heterotrophic-associated bacteria that frequently overgrow when using standard culture (ISO 11731, 1998; NF T90-431, 2003) methods. To improve Legionella pneumophila recovery from complex water samples (water from cooling towers, biofilms), we evaluated an immunomagnetic separation (IMS) assay using a monoclonal antibody raised against the lipopolysaccharide of Leg. pneumophila sg1 in combination with culture. Methods and Results: This study was conducted on 51 environmental specimens. The comparison between IMS-culture and standard culture (ISO 11731, 1998; NF T90-431, 2003) methods was made using ISO 17994, 2004 criteria for establishing equivalence between microbiological methods based on the upper and lower (X-H and X-L) values of the relative difference (95% confidence limit) and D as maximum acceptable deviation (value of the confidence limit). Conclusions: We found that the average performance of IMS culture was higher than the reference method. Significance and Impact of the Study: Thus, this IMS-culture assay is particularly well adapted to the detection of Leg. pneumophila sg1 in environmental samples with high levels of interfering microflora.
引用
收藏
页码:952 / 961
页数:10
相关论文
共 54 条
[1]
Rapid detection and enumeration of Legionella pneumophila in hot water systems by solid-phase cytometry [J].
Aurell, H ;
Catala, P ;
Farge, P ;
Wallet, F ;
Le Brun, M ;
Helbig, JH ;
Jarraud, S ;
Lebaron, P .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 2004, 70 (03) :1651-1657
[2]
Identification methods for Legionella from environmental samples [J].
Bartie, C ;
Venter, SN ;
Nel, LH .
WATER RESEARCH, 2003, 37 (06) :1362-1370
[3]
Development and evaluation of a Taqman duplex real-time PCR quantification method for reliable enumeration of Legionella pneumophila in water samples [J].
Behets, Jonas ;
Dederck, Priscilla ;
Delaedt, Yasmine ;
Creemers, Bart ;
Ollevier, Frans .
JOURNAL OF MICROBIOLOGICAL METHODS, 2007, 68 (01) :137-144
[4]
Salmonella and Escherichia coli O157:H7 contamination on hides and carcasses of cull cattle presented for slaughter in the United States:: an evaluation of prevalence and bacterial loads by Immunomagnetic separation and direct plating methods [J].
Brichta-Harhay, Dayna M. ;
Guerini, Michael N. ;
Arthur, Terrance M. ;
Bosilevac, Joseph M. ;
Kalchayanand, Norasak ;
Shackelford, Steven D. ;
Wheeler, Tommy L. ;
Koohmaraie, Mohammad .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 2008, 74 (20) :6289-6297
[5]
Evaluation of detection of Legionella spp. in water samples by fluorescence in situ hybridization, PCR amplification and bacterial culture [J].
Buchbinder, S ;
Trebesius, K ;
Heesemann, J .
INTERNATIONAL JOURNAL OF MEDICAL MICROBIOLOGY, 2002, 292 (3-4) :241-245
[6]
Specific Detection of Viable Legionella Cells by Combined Use of Photoactivated Ethidium Monoazide and PCR/Real-Time PCR [J].
Chang, Bin ;
Sugiyama, Kanji ;
Taguri, Toshitsugu ;
Amemura-Maekawa, Junko ;
Kura, Fumiaki ;
Watanabe, Haruo .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 2009, 75 (01) :147-153
[7]
Development of an immunomagnetic bead-immunoliposome fluorescence assay for rapid detection of Escherichia coli O157:H7 in aqueous samples and comparison of the assay with a standard microbiological method [J].
DeCory, TR ;
Durst, RA ;
Zimmerman, SJ ;
Garringer, LA ;
Paluca, G ;
DeCory, HH ;
Montagna, RA .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 2005, 71 (04) :1856-1864
[8]
Immunomagnetic separation of Cryptosporidium parvum oocysts using MACS MicroBeads and high gradient separation columns [J].
Deng, MQ ;
Lam, KM ;
Cliver, DO .
JOURNAL OF MICROBIOLOGICAL METHODS, 2000, 40 (01) :11-17
[9]
*DRINK WAT INSP, 2000, COMP METH DRINK WAT
[10]
Preparation of immunomagnetic iron-dextran nanoparticles and application in rapid isolation of E.coli O157:H7 from foods [J].
Duan, Hui-Li ;
Shen, Zhi-Qiang ;
Wang, Xin-Wei ;
Chao, Fu-Huan ;
Li, Jun-Wen .
WORLD JOURNAL OF GASTROENTEROLOGY, 2005, 11 (24) :3660-3664