An experimental investigation of effusivity as an indicator of powder blend uniformity

被引:36
作者
Leonard, G. [1 ]
Bertrand, F. [1 ]
Chaouki, J. [1 ]
Gosselin, P. M. [2 ]
机构
[1] Ecole Polytech, Dept Chem Engn, Montreal, PQ H3C 3A7, Canada
[2] Ratiopharm Operat, Ctr Res & Dev, Mirabel, PQ J7J 1P3, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
effusivity; process analytical technology; blend uniformity; density; powder mixing;
D O I
10.1016/j.powtec.2006.12.007
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Effusivity has recently been proposed as a process analytical technology (PAT) for monitoring the uniformity of powder blends resulting from pharmaceutical mixing processes. The objective of this work is to gain insight into the accuracy, sensitivity and limitations of effusivity as an indicator of blend uniformity. Two series of experiments were carried out. First, monitoring experiments were used to determine and compare the optimal blending times of a pharmaceutical mixture obtained by three different methods: effusivity, density and UV spectroscopy. A second series of experiments was conducted to quantify the influence of density on effusivity measurements. The potential of effusivity to be used as a tool for assessing blend uniformity is discussed. In particular, the results from these experiments reveal that the accuracy of effusivity in determining optimum blending times depends on the blend physical characteristics and is significantly influenced by density. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:149 / 159
页数:11
相关论文
共 40 条
[1]   USE OF A LIGHT PROBE FOR ASSESSING HOMOGENEITY OF POWDER MIXTURES [J].
ASHTON, MD ;
SCHOFIEL.C ;
VALENTIN, FH .
CHEMICAL ENGINEERING SCIENCE, 1966, 21 (10) :843-&
[2]  
Berman J, 2001, PDA J PHARM SCI TECH, V55, P209
[3]   BLEND UNIFORMITY AND UNIT DOSE SAMPLING [J].
BERMAN, J ;
PLANCHARD, JA .
DRUG DEVELOPMENT AND INDUSTRIAL PHARMACY, 1995, 21 (11) :1257-1283
[4]   Quantitative in-line monitoring of powder blending by near infrared reflection spectroscopy [J].
Berntsson, O ;
Danielsson, LG ;
Lagerholm, B ;
Folestad, S .
POWDER TECHNOLOGY, 2002, 123 (2-3) :185-193
[5]   Monitoring powder blending in pharmaceutical processes by use of near infrared spectroscopy [J].
Blanco, M ;
Bañó, RG ;
Bertran, E .
TALANTA, 2002, 56 (01) :203-212
[6]  
CARTENSEN JT, 1996, DRUG DEV IND PHARM, V22, P285
[7]   Effective mass sampled by NIR fiber-optic reflectance probes in blending processes [J].
Cho, J ;
Gemperline, PJ ;
Aldridge, PK ;
Sekulic, SS .
ANALYTICA CHIMICA ACTA, 1997, 348 (1-3) :303-310
[8]  
CLOSS S, 2004, AAPS CONV
[9]   A homogeneity study using NIR spectroscopy: Tracking magnesium stearate in Bohle bin-blender [J].
Duong, NH ;
Arratia, P ;
Muzzio, F ;
Lange, A ;
Timmermans, J ;
Reynolds, S .
DRUG DEVELOPMENT AND INDUSTRIAL PHARMACY, 2003, 29 (06) :679-687
[10]   Near-infrared spectroscopy and imaging for the monitoring of powder blend homogeneity [J].
El-Hagrasy, AS ;
Morris, HR ;
D'Amico, F ;
Lodder, RA ;
Drennen, JK .
JOURNAL OF PHARMACEUTICAL SCIENCES, 2001, 90 (09) :1298-1307