Choice of prosthetic heart valves: Update for the next generation

被引:21
作者
Bach, DS [1 ]
机构
[1] Univ Michigan, Div Cardiol, Dept Med, Ann Arbor, MI 48109 USA
关键词
D O I
10.1016/j.jacc.2003.06.009
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Intervention for valvular heart disease poses unique clinical challenges in cardiology because the diseases are of relatively low prevalence, the interventions do not lend themselves to randomized comparative trials, and important clinical end points are assessed only after decades of follow-up. In addition, continuing advances in prosthetic heart valve technology make follow-up a moving target because long-term data by definition are available only for older prostheses. Newer tissue and mechanical prostheses afford superior hemodynamics compared with their older counterparts, and data suggest that durability and patient mortality are superior with newer compared with older bioprostheses. Arbitrary cutoffs dictating valve choice based predominantly on patient age may not give appropriate weight to individual patient perspectives. In educating and counseling patients regarding choices in heart Valve prostheses, the clinician should help the patient weigh the relative merits for the individual patient of projected mortality, valve durability, and requirement for anticoagulation, with associated freedom from re-operation, hemorrhagic and thromboembolic risk, and impact on lifestyle. (C) 2003 by the American College of Cardiology Foundation.
引用
收藏
页码:1717 / 1719
页数:3
相关论文
共 18 条
[1]  
Bach D S, 2001, Semin Thorac Cardiovasc Surg, V13, P173
[2]   Hemodynamics and early clinical performance of the St. Jude Medical Regent mechanical aortic valve [J].
Bach, DS ;
Sakwa, MP ;
Goldbach, M ;
Petracek, MR ;
Emery, RW ;
Mohr, FW .
ANNALS OF THORACIC SURGERY, 2002, 74 (06) :2003-2009
[3]   Age and valve size effect on the long-term durability of the Carpentier-Edwards aortic pericardial bioprosthesis [J].
Banbury, MK ;
Cosgrove, DM ;
White, JA ;
Blackstone, EH ;
Frater, RWM ;
Okies, JE .
ANNALS OF THORACIC SURGERY, 2001, 72 (03) :753-757
[4]   12-YEAR COMPARISON OF A BJORK-SHILEY MECHANICAL HEART-VALVE WITH PORCINE BIOPROSTHESES [J].
BLOOMFIELD, P ;
WHEATLEY, DJ ;
PRESCOTT, RJ ;
MILLER, HC .
NEW ENGLAND JOURNAL OF MEDICINE, 1991, 324 (09) :573-579
[5]   Twenty-year follow-up of the Hancock modified orifice porcine aortic valve [J].
Cohn, LH ;
Collins, JJ ;
Rizzo, RJ ;
Adams, DH ;
Couper, GS ;
Aranki, SF .
ANNALS OF THORACIC SURGERY, 1998, 66 (06) :S30-S34
[6]   Aortic valve replacement with stentless and stented porcine valves: A case-match study [J].
David, TE ;
Puschmann, R ;
Ivanov, J ;
Bos, J ;
Armstrong, S ;
Feindel, CM ;
Scully, HE .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1998, 116 (02) :236-241
[7]   Late results of heart valve replacement with the Hancock II bioprosthesis [J].
David, TE ;
Ivanov, J ;
Armstrong, S ;
Feindel, CM ;
Cohen, G .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2001, 121 (02) :268-278
[8]  
Del Rizzo D F, 1999, Semin Thorac Cardiovasc Surg, V11, P1
[9]  
Doty D B, 1999, Semin Thorac Cardiovasc Surg, V11, P35
[10]   Refinement of the alpha aminooleic acid bioprosthetic valve anticalcification technique [J].
Gott, JP ;
Girardot, MN ;
Girardot, JMD ;
Hall, JD ;
Whitlark, JD ;
Horsley, WS ;
Dorsey, LMA ;
Levy, RJ ;
Chen, WL ;
Schoen, FJ ;
Guyton, RA .
ANNALS OF THORACIC SURGERY, 1997, 64 (01) :50-58