Theoretical modeling and evaluation of the axial resolution of the adaptive optics scanning laser ophthalmoscope

被引:42
作者
Venkateswaran, K [1 ]
Roorda, A [1 ]
Romero-Borja, F [1 ]
机构
[1] Univ Houston, Coll Optometry, Houston, TX 77204 USA
关键词
adaptive optics; scanning laser ophthalmoscopy; resolution; axial resolution;
D O I
10.1117/1.1627775
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We present axial resolution calculated using a mathematical model of the adaptive optics scanning laser ophthalmoscope (AOSLO). The peak intensity and the width of the axial intensity response are computed with the residual Zernike coefficients after the aberrations are corrected using adaptive optics for eight subjects and compared with the axial resolution of a diffraction-limited eye. The AOSLO currently uses a confocal pinhole that is 80 mum, or 3.48 times the width of the Airy disk radius of the collection optics, and projects to 7.41 mum on the retina. For this pinhole, the axial resolution of a diffraction-limited system is 114 mum and the computed axial resolution varies between 120 and 146 mum for the human subjects included in this study. The results of this analysis indicate that to improve axial resolution, it is best to reduce the pinhole size. The resulting reduction in detected light may demand, however, a more sophisticated adaptive optics system. The study also shows that imaging systems with large pinholes are relatively insensitive to misalignment in the lateral positioning of the confocal pinhole. However, when small pinholes are used to maximize resolution, alignment becomes critical. (C) 2004 Society of Photo-Optical Instrumentation Engineers.
引用
收藏
页码:132 / 138
页数:7
相关论文
共 16 条
[1]  
*AM NAT STAND I, 1993, Z13612000 ANSI
[2]   ODD ABERRATIONS AND DOUBLE-PASS MEASUREMENTS OF RETINAL IMAGE QUALITY [J].
ARTAL, P ;
MARCOS, S ;
NAVARRO, R ;
WILLIAMS, DR .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1995, 12 (02) :195-201
[3]  
BARTSCH D, 1994, VISION SCI ITS APPL, P134
[4]  
BENNETT AG, 1989, CLIN VISUAL OPTICS, V2
[5]  
BILLE JF, 1990, NONINVASIVE DIAGNOST, P528
[6]   Confocal laser scanning fluorescence topography: a new method for three-dimensional functional imaging of vascular structures [J].
Birngruber, R ;
Schmidt-Erfurth, U ;
Teschner, S ;
Noack, J .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2000, 238 (07) :559-565
[7]   Improved axial resolution by point-spread autocorrelation function imaging [J].
Brakenhoff, GJ ;
Muller, M .
OPTICS LETTERS, 1996, 21 (21) :1721-1723
[8]   SPECTRAL REFLECTANCE OF THE HUMAN OCULAR FUNDUS [J].
DELORI, FC ;
PFLIBSEN, KP .
APPLIED OPTICS, 1989, 28 (06) :1061-1077
[9]  
Diaz Santana Haro L, 1999, Opt Lett, V24, P61
[10]   ACTIVE OPTICAL DEPTH RESOLUTION IMPROVEMENT OF THE LASER TOMOGRAPHIC SCANNER [J].
DREHER, AW ;
BILLE, JF ;
WEINREB, RN .
APPLIED OPTICS, 1989, 28 (04) :804-808