Biocompatibility and biodegradation of intravitreal hyaluronan implants in rabbits

被引:52
作者
Avitabile, T
Marano, F
Castiglione, F
Bucolo, C
Cro, M
Ambrosio, L
Ferrauto, C
Reibaldi, A
机构
[1] Fidia Oftal, Res Labs, I-95127 Catania, Italy
[2] Univ Catania, Inst Ophthalmol, I-95124 Catania, Italy
[3] CNR, Inst Composite Mat Technol, I-80125 Naples, Italy
[4] Univ Catania, Chair Stat, I-95124 Catania, Italy
关键词
hyaluronan esters; scleral implant; biocompatibility; biodegradation; ultrasound biomicroscopy;
D O I
10.1016/S0142-9612(00)00169-1
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
To study the biocompatibility and the biodegradation rate in vivo of new intravitreal implants made with three different hyaluronic acid esters: Hyaff7, Hyaff11 and Hyaff11p75 (100% ethyl ester, 100 and 75% benzyl esters, respectively), the plugs were implanted through a sclerotomy at 3.5 mm from the limbus of rabbit eyes. In order to evaluate the in vivo biodegradation the shaft diameter of the plugs was measured by ultrasound biomicroscopy. Slit lamp microscopy, ophthalmoscopy and ERG were performed periodically. The effects of the implants on ocular tissues were also evaluated histologically. All the plugs showed a good biocompatibility. Plugs of both the total esters, Hyaff7 and Hyaff11, were found to undergo a slow dissolution process for 60 and 150 days, respectively. The partial benzyl ester, Hyaff11p75, was completely reabsorbed after 15 days. Analysis of variance showed a high correlation between biodegradation rate and the time of resorption (F = 90.5; p < 0.001). The biodegradation rate of each implant is related to the chemical structure of the three types of Hyaff (F = 4.51; p = 0.005). The present data suggest that intravitreal implants based on hyaluronic acid esters represent useful biocompatible and biodegradable devices for a potential drug delivery system in the treatment of posterior segment ocular diseases. (C) 2000 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:195 / 200
页数:6
相关论文
共 20 条
[1]  
Avitabile T., 1996, Investigative Ophthalmology and Visual Science, V37, pS396
[2]   Biocompatibility and biodegradation of different hyaluronan derivatives (Hyaff) implanted in rats [J].
Benedetti, L. ;
Cortivo, R. ;
Berti, T. ;
Berti, A. ;
Pea, F. ;
Mazzo, M. ;
Moras, M. ;
Abatangelo, G. .
Biomaterials, 1993, 14 (15) :1154-1160
[3]   Quantitative assessment of the tissue response to films of hyaluronan derivatives [J].
Campoccia, D ;
Hunt, JA ;
Doherty, PJ ;
Zhong, SP ;
ORegan, M ;
Benedetti, L ;
Williams, DF .
BIOMATERIALS, 1996, 17 (10) :963-975
[4]   INVITRO STUDIES ON BIOCOMPATIBILITY OF HYALURONIC-ACID ESTERS [J].
CORTIVO, R ;
BRUN, P ;
RASTRELLI, A ;
ABATANGELO, G .
BIOMATERIALS, 1991, 12 (08) :727-730
[5]   An intravitreal device providing sustained release of cyclosporine and dexamethasone [J].
Enyedi, LB ;
Pearson, PA ;
Ashton, P ;
Jaffe, GJ .
CURRENT EYE RESEARCH, 1996, 15 (05) :549-557
[6]  
FISHMAN PH, 1986, INVEST OPHTH VIS SCI, V27, P1103
[7]   Biodegradable polymeric device for sustained intravitreal release of ganciclovir in rabbits [J].
Hashizoe, M ;
Ogura, Y ;
Takanashi, T ;
Kunou, N ;
Honda, Y ;
Ikada, Y .
CURRENT EYE RESEARCH, 1997, 16 (07) :633-639
[8]   IMPLANTABLE BIODEGRADABLE POLYMERIC DEVICE IN THE TREATMENT OF EXPERIMENTAL PROLIFERATIVE VITREORETINOPATHY [J].
HASHIZOE, M ;
OGURA, Y ;
TAKANASHI, T ;
KUNOU, N ;
HONDA, Y ;
IKADA, Y .
CURRENT EYE RESEARCH, 1995, 14 (06) :473-477
[9]  
JOOHNDEPH BC, 1988, OPHTHALMIC SURG, V19, P252
[10]  
KIMURA H, 1994, INVEST OPHTH VIS SCI, V35, P2815