A chronoamperometric method to estimate changes in the membrane composition of ion-selective membranes

被引:39
作者
Pendley, BD
Gyurcsanyi, RE
Buck, RP
Lindner, E [1 ]
机构
[1] Univ Tennessee, Hlth Sci Ctr, Herff Coll Engn, Memphis, TN 38152 USA
[2] Univ Memphis, Joint Grad Program Biomed Engn, Memphis, TN 38152 USA
[3] Rhodes Coll, Dept Chem, Memphis, TN 38112 USA
[4] Hungarian Acad Sci, Res Grp Tech Analyt Chem, H-1111 Budapest, Hungary
[5] Univ N Carolina, Dept Chem, Chapel Hill, NC 27599 USA
关键词
D O I
10.1021/ac010007e
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new chronoamperometric method is used to estimate changes in the membrane composition of mobile-site, ionophore-based membranes. The characteristic features of the chronoamperometric curves (initial current, slope, break time) of valinomycin-based, potassium-selective membranes loaded with potassium tetrakis(4-chlorophenyl)borate are correlated with the mobile-site and free ionophore concentration in the membrane. Limiting cases for strong and negligible ion pair formation are distinguished. Replicate measurements indicate a relative standard deviation in the calculated values less than 10%. The practical applicability of the method was tested with membranes incorporated into conventional ion-selective electrode bodies or cast onto microfabricated planar sensor structures.
引用
收藏
页码:4599 / 4606
页数:8
相关论文
共 25 条
[1]   LIPOPHILIC SALTS AS MEMBRANE ADDITIVES AND THEIR INFLUENCE ON THE PROPERTIES OF MACROELECTRODES AND MICROELECTRODES BASED ON NEUTRAL CARRIERS [J].
AMMANN, D ;
PRETSCH, E ;
SIMON, W ;
LINDNER, E ;
BEZEGH, A ;
PUNGOR, E .
ANALYTICA CHIMICA ACTA, 1985, 171 (MAY) :119-129
[2]   PROPERTIES OF PVC BASED MEMBRANES USED IN ION-SELECTIVE ELECTRODES [J].
ARMSTRONG, RD ;
HORVAI, G .
ELECTROCHIMICA ACTA, 1990, 35 (01) :1-7
[3]   MECHANISTIC ASPECTS OF THE K+ ION-SELECTIVE ELECTRODE BASED ON VALINOMYCIN PVC [J].
ARMSTRONG, RD .
ELECTROCHIMICA ACTA, 1987, 32 (11) :1549-1552
[4]   DONNAN EXCLUSION FAILURE IN LOW ANION SITE DENSITY MEMBRANES CONTAINING VALINOMYCIN [J].
BUCK, RP ;
TOTH, K ;
GRAF, E ;
HORVAI, G ;
PUNGOR, E .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1987, 223 (1-2) :51-66
[5]   Potentiometric polymeric membrane electrodes for measurement of environmental samples at trace levels:: New requirements for selectivities and measuring protocols, and comparison with ICPMS [J].
Ceresa, A ;
Bakker, E ;
Hattendorf, B ;
Günther, D ;
Pretsch, E .
ANALYTICAL CHEMISTRY, 2001, 73 (02) :343-351
[6]   ION-SELECTIVE ELECTRODES USING AN IONOPHORE COVALENTLY ATTACHED TO CARBOXYLATED POLY(VINYL CHLORIDE) [J].
DAUNERT, S ;
BACHAS, LG .
ANALYTICAL CHEMISTRY, 1990, 62 (14) :1428-1431
[7]   LIFETIME OF NEUTRAL-CARRIER-BASED LIQUID MEMBRANES IN AQUEOUS SAMPLES AND BLOOD AND THE LIPOPHILICITY OF MEMBRANE-COMPONENTS [J].
DINTEN, O ;
SPICHIGER, UE ;
CHANIOTAKIS, N ;
GEHRIG, P ;
RUSTERHOLZ, B ;
MORF, WE ;
SIMON, W .
ANALYTICAL CHEMISTRY, 1991, 63 (06) :596-603
[8]   Producing "self-plasticizing" ion-selective membranes [J].
Heng, LY ;
Hall, EAH .
ANALYTICAL CHEMISTRY, 2000, 72 (01) :42-51
[9]   ION-TRANSPORT PROPERTIES OF CYCLIC AND ACYCLIC NEUTRAL CARRIER-CONTAINING MEMBRANES [J].
IGLEHART, ML ;
BUCK, RP .
TALANTA, 1989, 36 (1-2) :89-98
[10]   PLASTICIZED POLYVINYL-CHLORIDE) PROPERTIES AND CHARACTERISTICS OF VALINOMYCIN ELECTRODES - CURRENT TIME RESPONSES TO VOLTAGE STEPS [J].
IGLEHART, ML ;
BUCK, RP ;
HORVAI, G ;
PUNGOR, E .
ANALYTICAL CHEMISTRY, 1988, 60 (10) :1018-1022