Diagnosis of peripheral arterial disease in general practice: can the ankle-brachial index be measured either by pulse palpation or an automatic blood pressure device?

被引:35
作者
Aboyans, V. [1 ,2 ]
Lacroix, P. [1 ,2 ]
Doucet, S. [1 ]
Preux, P. -M. [2 ]
Criqui, M. H. [3 ]
Laskar, M. [1 ]
机构
[1] Dupuytren Univ Hosp, Dept Thorac Cardiovasc Surg & Vasc Med, F-87042 Limoges, France
[2] Univ Limoges, EA3174, IFR 175, F-87065 Limoges, France
[3] Univ Calif San Diego, Dept Family & Prevent Med, La Jolla, CA 92093 USA
关键词
D O I
10.1111/j.1742-1241.2008.01784.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Despite its validity as a screening test for peripheral arterial disease (PAD), and its prognostic value, the ankle-brachial index (ABI) is infrequently used in primary care, probably because a Doppler device is required, along with the requisite skill for its use. We hypothesized that ABI could be accurately measured either by pulse palpation (pABI) or automatic blood pressure devices (autoABI) instead of Doppler method (dABI). Design and methods: In 54 subjects, we compared the results and the intra-observer reproducibility of pABI to dABI, as well as the inter-observer reproducibility of both pABI and autoABI to dABI. Arm and ankle systolic pressures were measured by the three methods by two observers. The first observer repeated pABI and dABI measurements. The results were compared by the Student paired t-test. Reproducibility was assessed by the intra-class correlation coefficient of agreement (R) and the Bland and Altman method. Results: The mean dABI obtained by the first observers was 1.03 +/- 0.26 vs. a pABI of 0.85 +/- 0.44 (p < 0.0001) and an autoABI of 1.09 +/- 0.31 (p < 0.05). The intra-observer R-coefficient was at 0.89 for dABI vs. 0.60 for pABI (p < 0.05). The inter-observer R-coefficients were 0.79 for dABI vs. 0.40 for pABI (p < 0.05) and 0.44 for autoABI (p < 0.05). Conclusion: Neither pulse palpation nor automatic oscillometric devices can be recommended as reliable methods for ABI measurement.
引用
收藏
页码:1001 / 1007
页数:7
相关论文
共 27 条
[1]   The intra- and interobserver variability of ankle-arm blood pressure index according to its mode of calculation [J].
Aboyans, V ;
Lacroix, P ;
Lebourdon, A ;
Preux, PM ;
Ferrières, J ;
Laskar, M .
JOURNAL OF CLINICAL EPIDEMIOLOGY, 2003, 56 (03) :215-220
[2]   Can we improve cardiovascular risk prediction beyond risk equations in the physician's office? [J].
Aboyans, Victor ;
Criqui, Michael H. .
JOURNAL OF CLINICAL EPIDEMIOLOGY, 2006, 59 (06) :547-558
[3]  
ADISESHIAH M, 1987, ANN ROY COLL SURG, V69, P271
[4]  
*AHA PREV C 5 WRIT, 2000, CIRCULATION, V101, pE16
[5]   Critical issues in peripheral arterial disease detection and management - A call to action [J].
Belch, JJF ;
Topol, EJ ;
Agnelli, G ;
Bertrand, M ;
Califf, RM ;
Clement, DL ;
Creager, MA ;
Easton, JD ;
Gavin, JR ;
Greenland, P ;
Hankey, G ;
Hanrath, P ;
Hirsch, AT ;
Meyer, J ;
Smith, SC ;
Sullivan, F ;
Weber, MA .
ARCHIVES OF INTERNAL MEDICINE, 2003, 163 (08) :884-892
[6]   Validation of a new method of detecting peripheral artery disease by determination of ankle-brachial index using an automatic blood pressure device [J].
Benchimol, A ;
Bernard, V ;
Pillois, X ;
Hong, NT ;
Benchimol, D ;
Bonnet, J .
ANGIOLOGY, 2004, 55 (02) :127-134
[7]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[8]  
Blebea J, 1997, ARCH SURG-CHICAGO, V132, P286
[9]  
BREARLEY S, 1992, ANN ROY COLL SURG, V74, P169
[10]   THE SENSITIVITY, SPECIFICITY, AND PREDICTIVE VALUE OF TRADITIONAL CLINICAL-EVALUATION OF PERIPHERAL ARTERIAL-DISEASE - RESULTS FROM NONINVASIVE TESTING IN A DEFINED POPULATION [J].
CRIQUI, MH ;
FRONEK, A ;
KLAUBER, MR ;
BARRETTCONNOR, E ;
GABRIEL, S .
CIRCULATION, 1985, 71 (03) :516-522